References
306
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Reading Parameters
Label Gone Timeout
This feature sets the time after the last label segment is seen before the reader prepares for a new
label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55
seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a
trigger pull for each label that is read
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-
ing zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING.
5. Scan the appropriate three alpha-numeric characters from the keypad in
representing the duration which was determined in the steps above. You will hear a
two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table
for some examples of how to set this feature.
Table 40. Timeout Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
50ms
150ms
1800ms (1.8 sec.)
2550ms (2.55 sec.)
2
Divide by 10 (and pad with
leading zeroes)
005
015
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘5’
‘0’, ‘1’ and ‘5’
‘1’, ‘8’ and ‘0’
‘‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Gryphon I GD4100
Страница 38: ...Setup 36 Gryphon I GD4100 GM4100 GBT 4100 L GD4300 NOTES ...
Страница 42: ...Configuration Using Barcodes ENTER EXIT PROGRAMMING MODE 40 Gryphon I GD4100 GM4100 GBT 4100 L GD4300 NOTES ...
Страница 56: ...RS 232 USB Com Interfaces ENTER EXIT PROGRAMMING MODE 54 Gryphon I GD4100 GM4100 GBT 4100 L GD4300 NOTES ...
Страница 68: ...Keyboard Interface ENTER EXIT PROGRAMMING MODE 66 Gryphon I GD4100 GM4100 GBT 4100 L GD4300 NOTES ...
Страница 318: ...References 316 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Страница 330: ...Technical Specifications 328 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Страница 346: ...Sample Barcodes 344 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Страница 348: ...Keypad 346 Gryphon I GD4100 GM4100 GBT4100 L GD4300 6 7 8 9 ...
Страница 349: ...Keypad Product Reference Guide 347 A B C D E F ...
Страница 350: ...Keypad 348 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Страница 360: ...Scancode Tables 358 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...