background image

Gryphon™

 

GFE4400

Fixed Area Imaging

Bar Code Scan Engine

Integration Guide

Содержание Gryphon GFE4400

Страница 1: ...Gryphon GFE4400 Fixed Area Imaging Bar Code Scan Engine Integration Guide ...

Страница 2: ...e that all notices appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic web site www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about...

Страница 3: ... Connections 5 Host Interface 5 USB 7 RS 232 8 External Trigger and Digital Output 8 User Interface 10 Good Read Beep Interface 12 Scanner Ventilation 13 Integrating the Scanner to Read at the Proper Distance 14 Design of the Scanner Opening 15 Integrating the Scanner Behind a Window 16 ESD Protection 17 Technical Specifications 18 RS 232 Electrical Connections 22 Indicators 23 Error Codes 24 Mech...

Страница 4: ...NOTES ...

Страница 5: ...ry imaging technology excels at capturing hard to read bar codes in omni direction orientation A typical system using the scan engine consists of a host system such as a price verifier or kiosk The host system interfaces with the scan engine and receives decoded bar code data produced by the scan engine The il lumination LEDs in the scan engine emit visible light when a bar code passes through the...

Страница 6: ...can Engine The scan engine is shipped in custom packaging Carefully open the pack age and inspect for the following scan engine power supply if ordered interface cable if ordered If any parts are damaged or you need additional hardware please contact Technical Support Scan Engine Care The scan engine contains sensitive components which require special han dling Datalogic may not warrant damage due...

Страница 7: ...r Datalogic products The site offers product support product registration warranty information product manuals product tech notes software updates demos and instructions for returning products for repair Telephone Technical Support If you do not have internet or email access you may contact Datalogic technical support at 541 349 8283 or check the back cover of your manual for more contact informat...

Страница 8: ...een designed to be rugged it is important to consider the effect of the environment on the scanner In particular mounting should minimize the possibility of foreign objects coming into contact with the electronics Such contact could damage the device or re duce the scanner s performance Mounting The primary method of mounting to the host enclosure is to attach the scanner using the three mounting ...

Страница 9: ...hree application ports for device integra tion as indicated below a Host J1 User J2 and Good Read Beep In terface Figure 1 Scan Engine Application Ports Host Interface The Host Interface connection J1 provides all the connection points for either RS 232 or USB host communications Additionally this connec tor is input for power and provides access to the external triggering input and digital signal...

Страница 10: ...5C housing with DF13 12S 1 25C wire crimp terminals Figure 2 Interface Board bottom view Pin Number Pin Functionality 1 USB D 2 USB D 3 USB Shield 4 USB Shield 5 EXT_TRIGGER_IN input to thebase of a transistor pull high toactivate 6 RS232 TXD output from scanner 7 RS232 RTS output from scanner 8 RS232 RXD input to the scanner 9 RS232 CTS input to scanner 10 DIGITAL_OUT open collector 11 5V USB Vbu...

Страница 11: ...ide 7 USB For USB setup the recommended wiring is the following A compatible USB cable is available from Datalogic part number 770111600 Figure 3 USB Cabling It is important that connections 7 8 9 be wired together for USB Auto Detection ...

Страница 12: ...logic part number 770111700 Figure 4 RS 232 Cabling External Trigger and Digital Output The interface allows the user s adapting interface to trigger the scan engine if not set for Automatic Reading Mode Also a programmable digital out put signal is available which indicates a good read decode The figures on the following page provide interface suggestions ...

Страница 13: ...ections c OUT 10 12 GND USER INTERFACE GFE44X0 Vext 14Vdc max Output Connection HRS VCC 5 12 GND GFE44X0 11 TRIGGER EXT TRIGGER Input Trigger Using GFE44X0 Power HRS 5 12 GND GFE44X0 TRIGGER EXT TRIGGER Vext 5 Vdc max Input Trigger Using External Power HRS ...

Страница 14: ...vice The user connection J2 uses a Molex part number 0527460671 0 50mm 020 Pitch FFC FPC Connector Right Angle SMT ZIF Bottom Contact Style 6 Circuits Gold Contact Plating For custom ad aptations the integrator must interface using an FFC Flat Flexible Cable that mates properly to scan engine ZIF connector Figure 6 Top view The assignment of the J2 connector pins are indicated in the following ta ...

Страница 15: ...tor active low 3 LED3 Power hard wired to VCC internally 4 VCC_Out 5v for LED supply 5 Trigger Switch 6 Trigger Switch ground L3 POWER yellow ON Power ON OFF Power OFF L2 STATUS green ON Good Read Blinks USB enumeration or interface inac tive or waiting for change of configuration L1 TRIGGER blue ON Externaltrigger or button pressed or phase active Blinks During transferof captured image or during...

Страница 16: ... Interface connection J3 provides the integrator a means to tap the engine s good read beep signaling and interface with an external audio device The Beep Connection J3 is a Molex part number 53261 0271 1 25mm Pitch PicoBlade 2 Circuit Header To attach to this SMT Right Angle Header the integrator should use the Molex mating plug 51021 0200 and wire crimp terminal 50079 8000 or equivalent ...

Страница 17: ... for additional information about Good Read Beep output Figure 8 Beeper Connection Scheme Scanner Ventilation When mounting the scanner inside an enclosure it is important to have proper ventilation to ensure that the scanner temperature does not ex ceed the maximum range as listed in Technical Specifications on page 18 The reliability of the scanner may be compromised if the tem perature range is...

Страница 18: ...ead depending on the size of the bar code These distances or depth of field are specified in Technical Specifications on page 17 The scanner must be positioned so that the scan volume and illumination light will cover the entire bar code The scan volume is shown in Figure 9 The combination of the Scan Volume and the illumination light is called the Field of View Designing around the scanner Field ...

Страница 19: ...ning must not block any of the outgoing illumination light described by dimensions of the scanner Field of View Ensure that there are no reflective surfaces around the area of the scanner opening The minimum opening size must increase as the distance between the scanner and the host enclosure window increases This is necessary to accommodate the width and height of the scan volume The opening or o...

Страница 20: ...close to the illumination LEDs as possi ble to avoid LED ghost images or light reflections Tilting the window and or anti reflective coating can help mitigate illumina tion reflections Performance degradation may include The scan module will not read very low contrast labels The scan module will not be able to wake up especially in low ambient light typically 100Lux In this case the scan module ma...

Страница 21: ...surface should be ex posed in order to read bar codes This is to protect the rear interface con nector area which can be susceptible to static discharge Interface cables should also not have power applied when inserted into the scanner Any metal mounting surfaces for the scanner must be electrically grounded with proper insulation to the scan engine mounting Static discharge ESD testing is recomme...

Страница 22: ...held active until there is a good read decode or a determined timeout period Item Description Physical Characteristics Dimensions Height 28 2mm 1 11 Length 42mm 1 65 Width 48 mm 1 89 Weight without cabling Approximately 51 2 g 1 8 oz Electrical Characteristics Input Voltage 5 VDC 5 Overvoltage tolerantto 14VDC External Trigger Input 1V 5V Current Consumption for 1V 2mA max 5V 10mA max Min Pulse Du...

Страница 23: ...aximum Sink Current 200mA Maximum Sink Voltage 5V ESD protection limit Current Power Consumption Input current at 5V in Automatic Object Sense Reading Mode Operating typical 175 mA OnLine Serial OnLine Modes 165 mA Automatic Object Sense Mode Operating max 180 mA Idle standby typical 53 mA OnLine Serial OnLine Modes 100 mA Automatic Object Sense Mode No idle in Automatic Mode Performance Character...

Страница 24: ...l 3 8 0 8 0 2 16 8 32 3 48 3 1 5 0 3 0 1 6 6 12 7 19 0 EAN 7 5mil EAN 13mil 1 9 1 6 26 4 41 0 0 7 0 6 10 4 16 1 PDF 417 6 6mil PDF 417 10mil PDF 417 15mil 2 4 1 3 1 6 14 5 23 0 34 7 1 0 0 5 0 6 6 0 9 4 13 6 DataMatrix 10mil DataMatrix 15mil 1 8 0 3 16 2 23 7 0 7 0 1 6 4 9 3 QR Code 10mil QR Code 15mil 2 6 0 0 15 1 23 4 1 0 0 0 5 9 9 2 Minimum Element Width 1D Min Resolution 4 mil PDF 417 Min Resol...

Страница 25: ...ion LEDs 2D Stacked Codes TheGryphonIGFS4400scanneriscapableofdecodingthefollowingsymbologiesusingmultipleframes i e Multi FrameDecoding Datamatrix InverseDatamatrix Datamatrixisconfigurableforthefollowingparameters NormalorInverted SquareorRectangularStyle Datalength 1 3600characters Maxicode QRCodes QR MicroQRandMultiple QRCodes Aztec PostalCodes AustralianPost JapanesePost KIXPost PlanetCode Po...

Страница 26: ...Humidity Operating 5 to 90 relative humidity non condensing Ambient Light immunity Up to 100 000 Lux Regulatory LED Emission Class IEC 62471 2006 07 Exempt No Risk IEC60825 1 2007 9 pin connector 1 Trigger Trigger signal input 2 TX Transmit Data output from scanner 3 RX Receive Data input to scanner 4 NC Not connected 5 GND Ground 6 VCC 5Vdc 7 CTS Clear To Send input to scanner 8 RTS Request To Se...

Страница 27: ...figurableviathefeature GoodRead WhentoIndicate seetheGFS4400PRGforinformation ROMFailure Thereisanerrorinthereader ssoft ware programming Flashes Configuration Programming Mode Thescanengineisreadytoreadaconfigu rationlabeloracommandfromtheAlad dinConfigurationUtility TheLEDblinkscontinuously Reader Disabled Thereaderhasbeendisabledbythehost TheLEDblinkscontinuously GreenSpota flashes momentarily ...

Страница 28: ...as en tered FRU Field Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to see the FRU indication code from LED2 flashes The following table describes the LED flashes associated with an error found Number of LED2 Flashes Error Corrective Action 1 Configuration Contact Helpdesk for assistance 2 Interface PCB 6 Digital PCB 11 Imager ...

Страница 29: ...Integration Guide 25 Mechanical Specifications Physical Properties Scanner Dimensions Parameter Specification Dimensions 42 0mm x 48 0mm x 28 2mm 1 65 x 1 89 x 1 11 Weight 51 2 g 1 8 oz TOP VIEW ...

Страница 30: ...Mechanical Specifications 26 Gryphon GFE4400 Scanner Dimensions continued BOTTOM VIEW SIDE VIEW ...

Страница 31: ...Mechanical Specifications Integration Guide 27 Clearance Required for Integration TOP VIEW SIDE VIEW ...

Страница 32: ...Mechanical Specifications 28 Gryphon GFE4400 NOTES ...

Страница 33: ...Mechanical Specifications Integration Guide 29 NOTES ...

Страница 34: ...Mechanical Specifications 30 Gryphon GFE4400 NOTES ...

Страница 35: ...ర PART ㇱઙฬ 卋 ᳮ 叏 ચ卲 ᄙᄽ侶 ᄙᄽԲ ㅘ Printed Circuit Board Assembly 䏃ᵓ㒘ӊ X O O O O O Assy Optics Block ܝ ᄺ㒘ӊ X O O O O O Assy Module ܝ ᄺ㒘ӊ X O O O O O O ઍ ᱝẊㇱઙ ᚲ ဋ凝 ޗ றխࢬܶऱ具Ẋ ڶ ڶ ୭ढ凝 Պխ䦀Գ ا ٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ ޝ 䶣 ॾஒ䣈 խ ڶ ڶ ୭ढ凝ऱૻၦ ޣ ρ SJ T 11363 2006 億ࡳऱૻၦ ޕ X ઍ ᱝẊㇱઙᚲ ဋ凝 ޗ றխ ዋ 㮕 ᢱ ᚲ Ქ ኂ 凝 Պխ䦀Գ ا ٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ ޝ 䶣 ॾஒ䣈 խ ڶ ڶ ୭ढ凝ऱૻၦ ޣ ρ SJ T 11363 2006 億ࡳऱૻ ...

Страница 36: ...Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 683 5700 Fax 541 345 7140 2012 Datalogic ADC Inc 820049414 Rev X2 June 2012 www datalogic com ...

Отзывы: