M6xx Camera Connection
To connect M6xx camera trigger signals and strobe outputs, use cable 606-0674-xx (6 pin
Hirose Male to DB9) with terminal block 661-0399.
NOTE 1
: If Camera Trigger In requires a sinking signal, set the Software Trigger Event to Rising Edge. If it requires a
sourcing signal, set the Software Trigger Event to Falling Edge.
NOTE 2
: If Strobe Trigger Output requires a sinking signal, set the Strobe Trigger Output to Falling Edge. If it requires a
sourcing signal, set the Strobe Trigger Output to Rising Edge.
NOTE 3
: Disconnecting the camera will turn on some strobe lights.
Terminal Name
Signal
Notes
Optional Camera
Power
DO NOT USE
Do NOT apply power to this terminal if
Power is supplied by Power over
Ethernet (PoE
; enable/disable in
VPM-Settings
)
Optional Camera
Power Ground
DO NOT USE
Not required if Ground is supplied by
Power Over Ethernet (PoE
; enable/disable
in VPM-Settings
)
I/O Ground
I/O Ground
Trigger In**
Camera Trigger In
0 to +24 VDC (recommended
M24 VDC
As sinking input
Off: 0 to + 0.5 VDC
On: +3.3 to +24 VDC; 5 to 15 ma
As sourcing input (see Trigger VCC)
Off: +3.3 to +24 VDC; 5 to 15 ma
On: 0 to + 0.5 VDC
Trigger Pullup
+VCC**
Trigger In Pullup - use if
Trigger In needs sourc-
ing (see Note 1 below)
+24 VDC recommended
M24 VDC
(**Block contains 1.6k Ohm 1W resistor between Trigger In and
Trigger VCC)
Strobe Output
VCC*
Strobe Supply Voltage -
use if Strobe Trigger
Output needs sourcing
(see Note 2 below)
Based on Strobe requirement (optional)
Max: +30 VDC; 50 ma
(*Block contains 1.6k Ohm 1W resistor between Strobe Trigger
Output and Strobe Output VCC)
Strobe Trigger
Output*
Trigger Out to Strobe
(see Note 3 below)
DO NOT APPLY ANY VOLTAGE DIRECTLY TO THIS OUTPUT.
DO NOT WIRE OUTPUTS IN PARALLEL.
Содержание E1 Series
Страница 1: ...MX E Series Hardware Guide for Processor and Cameras Revision Date July 19 2018 ...
Страница 4: ......
Страница 18: ...Before You Call MX E Series Hardware Guide Datalogic S r l 12 ...
Страница 28: ...Battery MX E Series Hardware Guide Datalogic S r l 22 ...
Страница 44: ...M2xx and M3xx Camera Connection MX E Series Hardware Guide Datalogic S r l 38 M2xxandM3xxTerminalConnections ...
Страница 56: ...JAI Cameras MX E Series Hardware Guide Datalogic S r l 50 661 0402TerminalBlockDimensions ...
Страница 58: ...JAI Cameras MX E Series Hardware Guide Datalogic S r l 52 JAITerminalConnections sinking ...
Страница 64: ...Basler Cameras MX E Series Hardware Guide Datalogic S r l 58 TerminalConnections ...
Страница 116: ...M1xx and E1xx MX E Series Hardware Guide Datalogic S r l 110 ...
Страница 120: ...Index MX E Series Hardware Guide Datalogic S r l iv ...