Datalogic DX6400 Скачать руководство пользователя страница 2

DX6400 QUICK GUIDE 

 

 

UPDATES AVAILABILITY 

 
 

UK/US

 

The latest drivers and documentation updates for this product are available on Internet. 

 

Log on to: 

www.automation.datalogic.com

 

 

 

I

 

Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo 
prodotto. Collegarsi a: 

www.automation.datalogic.com

 

 

 

 

 

F

 

Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur 
Internet. Cliquez sur : 

www.automation.datalogic.com

 

 

 

 

 

D

 

Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem 
Produkt. Adresse : 

www.automation.datalogic.com

 

 

 

 

 

E

 

En Internet están disponibles las versiones actualizadas de los drivers y documentación de 
este producto. Dirección Internet : 

www.automation.datalogic.com

 

 

 

 
 
 

SERVICES AND SUPPORT 

 
 
Datalogic provides several services as well as technical support through its website. Log on to 

www.automation.datalogic.com

 and click on the links indicated for further information: 

 

PRODUCTS 

Search through the links to arrive at your product page which describes specific Info, Features, Applications, 
Models, Accessories, and Downloads including the Genius™ utility program, which allows device 
configuration using a PC. It provides RS232 and Ethernet interface configuration. 

 

SERVICE 

- Overview -

 Warranty Extensions and Maintenance Agreements

 

- Sales Network-

 Listing of Subsidiaries, Repair Centers, Partners

 

- Helpdesk 

- Material Return Authorization 

 
 
 

LEGAL NOTICES 

 
© 2003 - 2012 Datalogic Automation S.r.l. 

 ALL RIGHTS RESERVED. 

 Protected to the fullest extent under 

U.S. and international laws. Copying, or altering of this document is prohibited without express written consent 
from Datalogic Automation S.r.l. 
 
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the 
U.S.A. and the E.U. 
 

Genius, PackTrack, Step-a-Head, FLASH, ACR, and ID-NET are 

trademarks of Datalogic Automation 

S.r.l. All other brand and product names mentioned herein are for identification purposes only and may be 
trademarks or registered trademarks of their respective owners. 
 
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or 
consequential damages resulting from the use of this material. 
 

Содержание DX6400

Страница 1: ...twork applications For other types of installations such as ID NET Pass Through Multiplexer Layout etc refer to the DX6400 Reference Manual available on the CD For complete scanner configuration using...

Страница 2: ...t page which describes specific Info Features Applications Models Accessories and Downloads including the Genius utility program which allows device configuration using a PC It provides RS232 and Ethe...

Страница 3: ...2 4 3 Laser Beam Output Window 1 Laser Safety Label 2 Programming Keypad 1 Phase On LED Yellow 3 TX Data LED Green 2 Power On LED Red 4 LCD Display 5 Lonworks 9 pin Male Connector 1 Lonworks 9 pin Fem...

Страница 4: ...External Trigger PS input CBX100 jumper set to accept scanner power Encoder connected to Input 2 Encoder input Synchronized Network with DS8100A Master and 6K Family Slaves Serial Host CAB 610x CBX100...

Страница 5: ...ted by positioning a BT 6000 terminator on the DX6400 Standard master reader BT 6000 female side and on the last slave reader BT 6000 male side For Fieldbus models Lonworks master only the bus is inte...

Страница 6: ...rity insensitive only with CBX500 I4A IN 4A polarity insensitive only with CBX500 I34B IN 3B IN 4B Reference polarity insensitive only with CBX500 Outputs V Power Source Outputs V Power Reference Outp...

Страница 7: ...reference of IN3 and IN4 polarity insensitive 9 13 VS Supply voltage positive pin 23 25 26 GND Supply voltage negative pin 14 1 25 13 25 pin male D sub Connector 10 19 1 18 9 26 26 pin male D sub Con...

Страница 8: ...85 half duplex 1200 to 115200 Auxiliary RS232 1200 to 115200 Other Common Communication Interfaces Lonworks 1 25 Mb s Model Dependent Communication Interfaces Ethernet 100 Mb s Inputs Ext Trigger 1 En...

Страница 9: ...nd Terminators Up to 128 bytes headers and 128 bytes terminators Operating Modes On Line Serial On Line Automatic Test PackTrack Continuous Configuration Modes Genius utility program Parameter Storage...

Страница 10: ...pin to 17 pin 93A051288 CAB 6505 Fam 6K 8K cross cable 5 m 9 pin to 17 pin 93A051289 CAB ETH M01 M12 IP67 Ethernet Cable 1 m 93A051346 CAB ETH M03 M12 IP67 Ethernet Cable 3 m 93A051347 CAB ETH M05 M1...

Страница 11: ...ut don t remove the two screws on top of the head 4 affix the head onto the base carefully aligning the four fixing screws and progressively tightening them about half way 5 completely tighten the two...

Страница 12: ...NAMIC FOCUS The DX6400 has an innovative linear motor designed to control the focus position of the scanner via software This dynamic system called FLASH is able to move the focus position rail to rai...

Страница 13: ...21 23 26 Code 39 Code Resolution mm 1 00 28 29 30 31 32 34 Table 2 Minimum Code Height for Omnidirectional Reading mm Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 38 10 12 14 16 18 20 0 50 12 13 16 18 20 22...

Страница 14: ...o the edge of the DX6400 scanner as shown in the figure above CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 DX6400 100 0XX Resolution 0 50 mm 20 mils in in cm cm 20 40 10 30 10 0 10 20 30 10 0 4...

Страница 15: ...IS APERTURE AVOID EXPOSURE TO BEAM CAUTION LASER LIGHT WHEN OPEN AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE Laser Safety Labels DX6400 CAUTION CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSU...

Страница 16: ...ed operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protec...

Отзывы: