DS8100A-3002 QUICK GUIDE
8
Mechanical Installation:
DS8100A-3002 can be installed to operate in any position. There are 16 screw holes (M6 X 8) on the sides of the
scanner for mounting. The following diagrams give the overall dimensions of the reader standard model and
mounting bracket. They may be used for their installation:
12
7
[4
.9
8]
173
[6.79]
21
7
[8
.5
4]
50
[1
.9
7]
68
[2.66]
45°
47
[1.84]
45°
50
[
1
.9
7]
47
[1
.8
4]
68
[2
.6
6]
M6 N°16
mm
inch
164
[6.45]
[0
.19]
5
100
[3
.93]
30
[1
.18]
16
[0.63]
100
[0.59]
R 15
[1.88]
48
[0.59]
R 15 N°4
[3.93]
15
[0.59]
164
[6.45]
80
[3
.1
5]
45
[1.77
]
17.5
[0
.68]
8.5 N°
4
[0
.33]
DS8100A-3002 Overall Dimensions
ST-163 Mounting Bracket Overall Dimensions
WARNING
When installing several scanners, take care to position them correctly so that no laser beam
enters the reading window perpendicularly and at the same level of the output beam of the
other scanners. This condition could occur more frequently for side mounted applications. If
these precautions are not followed, it may occur that the laser of the blinded scanner starts
blinking due to an internal circuit which temporarily turns the laser off when detecting a power
anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position
of one of the two scanners involved.
mm
inch
mm
inch