CUSTOM CABLE ELECTRICAL CONNECTIONS
41
4
4.2.3 RS485
Half-Duplex
Interface
NOTE
This interface is provided for backward compatibility. We recommend using
the more efficient Lonworks network for Master/Slave or Multiplexer layouts.
The RS485 half-duplex (3 wires + shield) interface can be used for polled communication
protocols.
It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. "Multiplexer"
in Appendix A) exploiting a proprietary protocol based on polled mode called MUX32
protocol, where a master device polls slave devices to collect data. The overall maximum
cable length should not exceed 1200 m (3940 ft).
The following pins of the 25/26-pin connector are used for RS485 half-duplex interface
connection:
Pin Name
Function
2
RTX+
RS485 input/output (+)
4
RTX-
RS485 input/output (-)
7 GND_ISO
Main
signal
ground
DS6300
7
GND_ISO
RTX+
2
RTX-
4
RS485REF
MULTIPLEXER
RTX485-
1
Earth
Ground
CHASSIS
Figure 58 – RS485 Half-Duplex Interface Connections
This interface is forced by software when the protocol selected is MUX32 protocol.
In a Multiplexer layout, the Multidrop address must also be set via serial channel by the
Genius™ utility or by the Host Programming Mode.
Figure 59 shows a multidrop configuration with DS6300 scanners connected to a Multiplexer.
CAUTION
This is an example of multidrop wiring. Consult the multiplexer manual for
complete wiring instructions.
Содержание DS6300
Страница 1: ...DS6300 Reference Manual ...
Страница 58: ...DS6300 REFERENCE MANUAL 42 4 Figure 59 DS6300 Multidrop Connection to a Multiplexer ...
Страница 129: ...www automation datalogic com ...