background image

 

 

DS2400A QUICK GUIDE

 

3

 

 

Accessories: 

 

Name Description 

Part 

Number 

GFC-2100 

90° Reading Device 

93A201000 

GFC-2000 

105° Reading Device 

93A201080 

OM2000 Oscillating 

Mirror 

93A251031 

INT-30  

(for C-Box 100)

 

20 mA Current Loop Interface Board 

93A151022 

C-BOX 100/200 

Connection Box 93ACC1510, 

93ACC1520 

C-BOX 300/310 

Connection Box Profibus 93A301000, 

93A301030 

C-BOX 400/410 

Connection Box DeviceNet 93A301010, 

93A301040 

MEP-542/543 Photocell 

Kit 

NPN/PNP 93ACC1727, 

93ACC1728 

 
 

Electrical Connections: 

 
DS2400A is equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power 
supply, communication interface and input/output signals. You can bring system cables directly to the 25-pin 
connector or you can connect the scanner directly to one of the various C-Box models and bring system wiring to 
it (see the relative C-Box Installation Manual). 
 

 

CAUTION 

Do not connect GND and SGND to different (external) ground references. GND and SGND 
are internally connected through filtering circuitry which can be permanently damaged if 
subjected to voltage drops over 0.8 Vdc. 

 
The details of the connector pins are indicated in the following table: 

25-pin D-sub female connector pinout 

Pin Name  Function 

13 

VS 

Power supply input v 

25 

GND 

Power supply input voltage - 

1 CHASSIS 

Chassis 

Ground 

VS 

External Trigger supply v 

18 

EXT TRIG+  External T 

19 

EXT TRIG- 

External Trigger - 

OUT1 + 

Output 1 + 

11 

OUT2 + 

Output 2 + 

12, 22  

OUT REF 

Output reference 

20 RXAUX Auxiliary 

RS232 

21 TXAUX Auxiliary 

RS232 

23 

CTSAUX 

Auxiliary handshake RS232 

24 

RTSAUX 

Auxiliary handshake RS232 

6, 10, 14, 

15, 16, 17 

NC Not 

Connected 

 

25-pin female connector

 

Pin RS232 

RS485 

Full-Duplex 

RS485 

Half-Duplex 

2 TX232 

TX485+ 

 

3 RX232 

RX485+ 

 

4 RTS232 

TX485- 

RTX485- 

5 CTS232 

RX485- 

 

SGND SGND SGND 

 

Содержание DS2400A

Страница 1: ...ee the complete Reference Manual on the installation CD ROM DS2400A can be configured through the WinHost Windows based software program available on the installation CD ROM For configuration it is necessary to create a cable connecting the scanner to the PC as indicated in the How To Build A Simple Interface Test Cable section of this guide otherwise you can use the C Box 100 Power Supply This pr...

Страница 2: ...rrent Consumption 25 mA Operating Modes On Line Automatic max Serial On Line Test Outputs Configuration Modes Through menus using OUT1 OUT2 optocoupled WinHost utility Host Mode commands from VCE max 40 Vdc one of the serial ports Collector Current 40 mA continuous Code Selection Up to six different codes max 130 mA pulsed during one reading phase VCE Saturation 1V at 10 mA max Decoding Safety Can...

Страница 3: ... and bring system wiring to it see the relative C Box Installation Manual CAUTION Do not connect GND and SGND to different external ground references GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0 8 Vdc The details of the connector pins are indicated in the following table 25 pin D sub female connector pinout ...

Страница 4: ...wer MEP 543 Connector DS2400A 18 19 5V VS 9 25 GND EXT TRIG EXT TRIG 4 3 2 1 brown white blue Input NPN command using MEP 543 Photocell OUTPUT EXTERNAL TRIGGER DS2400A Signal 18 19 5V VS 9 25 GND Ground V EXT TRIG EXT TRIG Input NPN command using DS2400A power USER INTERFACE 8 11 12 22 OUT REF DS2400A Vext 40 Vdc max C E Output open collector connections INPUT PNP 18 19 5V DS2400A EXTERNAL TRIGGER...

Страница 5: ...al Interface RS232 c Main Serial Interface RS485 Half Duplex dAuxiliary Serial Interface RS232 dAuxiliary Serial Interface Local Echo RS232 eExternal Trigger for On Line Mode eExternal Trigger for On Line Mode RS232 Master slave layout RS485 Master slave layout c Main Serial Interface Slaves RS232 only c Auxiliary Serial Interface RS232 dAuxiliary Serial Interface RS232 d Main Serial Interface RS4...

Страница 6: ...35 cm 3 4 in 1 2 0 1 2 3 4 2 6 4 12 8 10 14 in 0 35 mm 14 mils 0 20 mm 8 mils 0 25 mm 10 mils DS2400A 1200 Medium Reading Range CONDITIONS Optic Version Linear Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle 10 Tilt angle 0 Code Resolution High for 0 25 mm 10 mils codes Std for 0 35 mm 14 mils codes and greater Code Reading Condition Standard Scanning Speed Speed_3 800 scans s Pa...

Страница 7: ... Interface The following table contains the pinout for standard RS232 PC Host interface For other user interface types please refer to their own manual RS232 PC side connections 5 9 6 1 9 pin male connector 13 25 14 1 25 pin male connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagram shows a simple...

Страница 8: ...compatibility and product safety Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las...

Отзывы: