DATALOGIC
DS2200
Installation - 9
An anti-disturbance hardware filter is implemented on the External Trigger
input (<5 milliseconds delay).
An additional 15 ms (typical) delay can be implemented through a dedicated
software parameter (refer to WinHost Help On Line).
2.3.5 Outputs
The following pins are present on the connector of the scanner:
Pin
Name
Function
8
OUT1+
Output 1 +
10
I/O REF
I/O Reference
11
OUT2+
Output 2 +
12
I/O REF
I/O Reference
The meaning of the two outputs OUT1 and OUT2 can be defined by the user
(No Read, Right or Wrong). Refer to the Winhost Help On Line.
By default, OUT1 is associated with the No Read event, which activates
when the code signalled by the External Trigger is not decoded, and OUT2 is
associated with the Right event, which activates when the code is correctly
decoded.
DS2200
USER INTERFACE
Vext 50 Vdc max, 50 mA max.
OUT1+
OUT2+
8/11
10/12
I/O REF
Figure 2.9 - DS2200 output connections
These outputs are both level or pulse configurable.