CBX ELECTRICAL CONNECTIONS
37
4
NOTE
To avoid electromagnetic interference when the scanner is connected to a
CBX connection box, verify the jumper positions in the CBX as indicated in
its Installation Manual.
4.1 POWER SUPPLY
Power can be supplied to the scanner through the CBX100/500 spring clamp terminal pins
as shown in Figure 38:
V+
in
Earth
Ground
Power Supply
VGND
Figure 38 - Power Supply Connections
The power must be between 10 and 30 Vdc only.
It is recommended to connect the device CHASSIS to earth ground (Earth) by setting the
appropriate jumper in the CBX connection box. See the CBX Installation Manual for details.
4.2 MAIN SERIAL INTERFACE
CAUTION
Do not connect to the Main Interface spring clamp terminals if using Host
Interface Modules (Fieldbus) with the CBX500.
The signals relative to the following serial interface types are available on the CBX spring
clamp terminal blocks.
If the interface type is not compatible with the current communication handshaking, then the
system forces the handshake to
none
.
The main interface type and the relative parameters (baud rate, data bits, etc.) can be
set using the Genius™ utility program or the Genius™ based Host Mode Programming
procedure.
Details regarding the connections and use of the interfaces are given in the next paragraphs.
Содержание DS2100N
Страница 1: ...DS2100N Reference Manual ...
Страница 20: ...DS2100N REFERENCE MANUAL 10 1 b Operating mode selection and definition c Digital Outputs configuration ...
Страница 54: ...DS2100N REFERENCE MANUAL 44 4 Figure 46 ID NET Network Connections with isolated power blocks ...
Страница 55: ...CBX ELECTRICAL CONNECTIONS 45 4 Figure 47 ID NET Network Connections with Common Power Branch Network ...
Страница 56: ...DS2100N REFERENCE MANUAL 46 4 Figure 48 ID NET Network Connections with Common Power Star Network ...
Страница 69: ...25 PIN CABLE ELECTRICAL CONNECTIONS 59 5 Figure 68 DS2100N Multidrop Connection to a Multiplexer ...
Страница 72: ...DS2100N REFERENCE MANUAL 62 5 Figure 70 ID NET Network Connections with isolated power blocks ...
Страница 73: ...25 PIN CABLE ELECTRICAL CONNECTIONS 63 5 Figure 71 ID NET Network Connections with Common Power Branch Network ...
Страница 74: ...DS2100N REFERENCE MANUAL 64 5 Figure 72 ID NET Network Connections with Common Power Star Network ...
Страница 119: ...www datalogic com ...