06656
17
CTS
Like XON/XOFF protocol, CTS protocol is a mechanism used to con-
trol data flow out. The CTS input is used to inform the scanner that
the host terminal is ready to accept scanned data. When CTS (+) pro-
tocol is selected, the scanner waits for a low level on its CTS input
before transmitting data. When CTS (-) is selected, the signal polari-
ties are reversed and a high level indicates data may be transmitted.
The CTS protocol may be programmed independently of the RTS pro-
tocol; however, the signal polarities must be the same. You may not
select CTS (+) and RTS (-).
RTS
The RTS output from the scanner may be programmed to operate in
one of three different modes. In the default mode RTS signals when
the scanner is ready to receive commands or data. In the second
mode, RTS is in a fixed state. In the third mode, RTS signals when the
scanner has data to transmit. The RTS modes are independent of the
CTS protocol. However, you must select the same active state for RTS
as for CTS. You may not select CTS (-) and RTS fixed low. If CTS (-) is
selected, then the active state for RTS will be high.
NOTE
The specified levels are at the modular connector and are
inverted when using an RS232 converter pod.
HA
CTS Protocol = None*
RTS low indicates scanner ready to
receive data
HB
Protocol = XON/XOFF
HC
Protocol = CTS (-)
Содержание DS1100 SH2347
Страница 1: ...User s Programming Guide Handheld Laser Bar Code Scanners Keyboard Wedge Wand Emulation Interface ...
Страница 4: ...NOTES ...
Страница 8: ...iv User s Programming Guide NOTES ...
Страница 61: ...06656 53 Digit Selection 5 0 6 1 7 2 8 3 9 4 ...
Страница 69: ...06656 61 XE Active Polarity High XF Active Polarity Low ...
Страница 73: ...06656 65 300 ms 50 MS 350 MS 100 MS 400 MS 150 MS 450 MS 200 MS 500 MS 250 MS ...
Страница 85: ...06656 77 NOTES ...
Страница 86: ...78 User s Programming Guide NOTES ...