DL CORDLESS CARD™
4
This string is always transmitted in a single frame preceding the one containing
the configuration command, as shown in the following examples:
Example
1
Sending the $+$![CR] command to transmit the card software release:
1
st
Frame = #+++P++#
2
nd
Frame = $![CR]
Example
2
Sending the $+ML0$-[CR] command to set the default frame packing
configuration:
1
st
Frame = #+++P++#
2
nd
Frame = ML0$-[CR]
4.3 DATA
FORMAT
4.3.1 Header/Terminator
Selection
The header/terminator selection is not effected by restore default command.
Header Position
This parameter defines the header position within the frame to be transmitted from
DLCC to the Host. The header can be positioned in either the first field of the frame
or in the field preceding the message:
FRAME
HEADER
Address Address
Delimiter
MESSAGE
HEADER
Time-Stamp
Time-Stamp-Del
Code Id
Code Len
DATA
Terminator
The Address field has different meanings depending on if the FRAME is a 2 way
answer to a previous 2 way transaction initiated by a DLCC Client, or if it is a new
message that an RF device sends to the DLCC Server. See par. 4.3.2 for details.
26
Содержание DL Cordless Card DLCC
Страница 14: ...xiv...