DEVICE USE 

 

CONNECTION TO DATAVS2 

 
To connect the VSM to DataVS2, just 
select the sensor from the list displayed in 
the “Net discovering” function.  
Use the ARROW buttons to select the 
sensor and press SET to confirm the 
selection. If no devices have been found in 
the first discovery, a new search can be 
made by pressing 

TEACH

 
 

ADJUST MODE 

 
Once connected the desired DataVS2, the 
VSM enters in the MONITOR mode and 
the current inspection is displayed together 
with the results of the relative tools. 
 
 
 
 
 
 
By pressing TEACH, the VSM will display the following panel: 
 

 

 
At this point the user can choose to change the current inspection or modify 
the parameters. 
 
 

Change of the Sensor Parameters and Tools 

 
Selecting “Adjust Current Inspection” the user accesses the main panel of the 
Adjust status: 
 

 

 
 

 

Only the parameters that have been previously enabled by the 
GUI as “Adjustable”, can be displayed and changed. 

 
 
By selecting “Camera”, the user can 
access the parameters that adjust the 
brightness of the acquired image, 
exposure time, gain and operating mode of 
the illuminator. 
 
 
 
 
 
 
 
By selecting “Tools”, the user can access 
the panel shown in the figure, and select 
the tools, on which changes are to be 
carried-out, using the arrows.  
Press SET to select the tool. 
 
 

 Once selected the tool, the user can scroll 
the panels relevant to the different 
parameters enabled as “Adjustable” using 
the ARROWS (right and left). 
The user can choose to move, resize or 
rotate the ROI by using the ARROW 
buttons (Up, Down) in the specific ROI 
adjustment panel. The adjustment can be 
carried-out using the 4 ARROW buttons 
once selected the operation by pressing 
SET. 
 
 

     

 

 
 
In panels that allow the change of the other parameters, the new value can be 
selected by moving the slider shown on the right side of the display. In order 
to correctly adjust parameters, these panels display the current inspection 
result relevant to the new configuration. 
The ROI contour and the result bar become green if the result is positive and 
red if negative. 
 
 

Current Inspection Change 

 
The following panel is displayed by pressing TEACH always from the monitor 
status: 
 

 
 
 
By selecting “Change Current Inspection” 
the user can access another panel where 
the inspection to carry-out can be selected. 
 
 
 
 
 
 
The inspection can be changed by simply 
pressing SET on the name of the desired 
inspection. 
At this point DataVS2 carries-out the new 
inspection and the monitor status is 
restored. 
 
 

 
 

INSPECTION MONITORING AND SAVING 

 
The monitor mode allows the user to control the result of the configured 
inspection. Different visualisations modes are available that can be recalled 
using the ARROW buttons. The SET button, instead, activates the statistics 
panel. 
 
 

Monitor Mode

 

To Activate 
Press 

View 

 

Standard 

 

 

Active by default 

-

 Acquired image 

-

 Tool used 

-

 Result 

 

 
 
 
 
 
 

Monitor Mode 

To Activate 
Press 

View 

 

 

 

Tool Result 

 

 

DOWN ARROW 

-

 Tool result 

Display on Condition 

 

 

ESC BUTTON 

-

 Acquired image 

-

 Tool used 

Zoom 

 

 

UP ARROW 

-

 Acquired image 

(with 200% zoom) 

-

 Tool used 

-

 Result 

 

Statistics 

 

 

 

 

SET BUTTON 

-

 Inspection result 

-

 Execution time 

-

 Inspections carried-out 

-

 Failure rate (%) 

-

 Score 

-

 Average score 

-

 MIN-MAX score 

 

NOTE: 

The statistics of 

the single tools can be 
displayed by pressing 

STATUS.

 

 
 

MAIN SCREEN DESCRIPTION 

 
The “System” panel is the main menu of the VSM unit and it allows the 
access to all the other panels and the relative functions available. 

 

System 

 

Press STATUS from Monitor mode to access 
the “System” panel. 
When the VSM is already connected to 
DataVS2, the 

“Disconnect” 

icon is displayed. 

To disconnect DataVS2, the icon has to be 
selected and SET pressed. 

 

Monitor System Settings 

 

This panel displays all the information relevant 
to the VSM unit such as name, serial number, 
model Firmware version, etc… 
This panel allows changing the network 
parameters such as IP Address and NetMask. 
The data relevant to the last sensor connected 
are displayed on the bottom. 

 

 

Sensor Settings 

 

This panel is used to change the network 
parameters, when the VSM is connected to a 
DataVS2. 

 

 

Memory Management 

 

The control of the memory slots is divided in two 
parts: the “Monitor” section manages the VSM 
memory slots while the Sensor” section 
manages the memory slots of the DataVS2. The 
slots can be cancelled and/or exchanged 
between the two devices. 

 

 

Factory Reset 

 

The reset of the default settings of the VSM is 
possible. All the memory slots are going to be 
cancelled, the network parameters changed 
and passwords cancelled. 

 

 

Sensor List 

 

Once carried-out a “Net discovery”, the list of 
DataVS2 devices present in the subnet 
connected to the VSM, is displayed. 
To connect the desired sensor, the user has to 
simply select it from the list and press SET. 

 

 

Account Selection 

The user typology can be changed in this panel. 
To proceed with the changes, the user has to 
simply digit the password relevant to the new 
typology. 

 

 

Language 

 

The “Language” panel allows to change the 
language system of the device. 

 

 
 
 

 

COMPLIANCE 

Only connect Ethernet and dataport connections to a network which has routing only within the plant or 
building and no routing outside the plant or building. 
 

CE COMPLIANCE 
Warning:

 This is a Class A product. In a domestic environment this product may cause radio 

interference in which case the user may be required to take adequate measures. 
 

FCC COMPLIANCE 

Modifications or changes to this equipment without the expressed written approval of Datalogic could 
void the authority to use the equipment. 
 
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference which may cause undesired operation. 
 
This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own expense. 

DECLARATION OF CONFORMITY 

We DATALOGIC AUTOMATION declare under our sole responsibility that these products are conform 
to the 2004/108/CE and successive amendments. 

 

WARRANTY 

DATALOGIC AUTOMATION warrants its products to be free from defects. 
DATALOGIC AUTOMATION will repair or replace, free of charge, any product found to be faulty 
during the warranty period of 36 months from the manufacturing date. 
This warranty does not cover damage or liability deriving from the improper application of DATALOGIC 
products. 

 

DATALOGIC AUTOMATION 

Via Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy 
Phone: +39 051 6765611 Fax: +39 051 6759324 

www.automation.datalogic.com  e-mail: [email protected]

 

 

 

DATALOGIC AUTOMATION for the environment: 100% recycled paper. 
DATALOGIC AUTOMATION reserves the right to make changes or improvements to products at any time without
prior notice.

 

Datalogic and the Datalogic logo are registered  trademarks of Datalogic S.p.A. in many countries, 

including the U.S.A. and the E.U. 

826000141 Rev.A

 

© Copyright Datalogic 2011

 

Отзывы: