2.2 REQUIRED
PARTS
Other than the various scanners used for the reading station, the following parts are necessary to
construct the redundancy station:
Name Description
Part
Number
SC6000
SC6000-1200 Universal Controller, Ethernet
935701000
PWO-480
J-box power unit 110/230 VAC 24 V 480 W
93ACC1767
CAB-SC6013
25p cable SC6000 to PWO PWR/NET, 3 m
(for Power/Net connections)
93A051337
CAB-SC6003
25p cable SC6000 to PWO I/O, 3 m
(for Extended I/O connections)
93A051338
CAB-SC6103
9p cable SC6000 to PWO, 3 m
(for serial connections if used)
93A051294
CAB-PWO 03
17p cable PWO to PWO, 3 m
(for redundancy)
93A051295
BTK-8100
Bus terminator kit (5 pcs)
93ACC1090
CAB-8101
17-pin scanner/scanner connection cable 1.2 m
93A051020
CAB-8102
17-pin scanner/scanner connection cable 2.5 m
93A051030
CAB-8105
17-pin scanner/scanner connection cable 5 m
93A051040
PH-1
Photocell kit - PNP
93ACC1791
OEK-2
Optical Encoder (Cab 10 Spring)
93ACC1770
2.3 REDUNDANT SYSTEM INSTALLATION
1. Install the two SC6000/PWO groups, each with its own Encoder and PS, using the cables and
accessories listed in the parts table (standard hardware configuration). See the relative product
Reference Manual.
2. Install the scanner branches distributed equally between the two PWOs. See the relative
product Reference Manual and see the paragraph
2.6 Redundancy Scanner Connections
this manual.
3. Connect the CAB-PWO 03 Redundancy cable between the two PWOs.
4. Decide which SC6000/PWO group will be
Working
Controller and which will be
Protecting
Controller. Consequently set the PWO-480 switches as shown in the table below.
Topology Role
LON TERM
IN3
REDUNDANCY
SRC
SEL
Working
ON ON PWR
PWR
1 1 1 1 1 1
RE RE
STD
STD
Protecting
ON ON PWR
PWR
1 1 1 1 1 1
RE RE
REV
REV
Scanners
8K TERM
8K BYP
8k only
ON ON OFF
OFF
6k only
OFF
OFF
ON ON
Both 6k and 8k
OFF
OFF
OFF OFF
5. Power up the system and perform a Restore Default with Environmental Parameters on both
SC6000s: With Genius
Menu Bar
Device Menu
Send with Options
select
Default Para Environmental Parameters
OK
6. Disconnect
the
Protecting
Controller from the PWO.