![Datalogic Cobalto C05300 Скачать руководство пользователя страница 249](http://html.mh-extra.com/html/datalogic/cobalto-c05300/cobalto-c05300_product-reference-manual_511833249.webp)
Reading Parameters
Product Reference Guide
237
Reading Parameters
Label Gone Timeout
This feature sets the time after the last label segment is seen before the scanner prepares for
a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds
(2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that
require a trigger pull for each label that is read
Follow these instructions to set this feature:
1.
Determine the desired setting in milliseconds.
2.
Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with
leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
3.
Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4.
Scan the bar code: SELECT LABEL GONE TIMEOUT SETTING.
5.
Scan the appropriate three alpha-numeric characters from the keypad in
representing the duration which was determined in the steps above. You will hear a
two-beep indication after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code to
abort and not save the entry string. You can then start again at the begin-
ning.
6.
Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this feature.
Table 18. Timeout Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
50ms
150ms
1800ms (1.8
sec.)
2550ms (2.55 sec.)
2
Divide by 10 (and pad with
leading zeroes)
005
015
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘5’
‘0’, ‘1’ and ‘5’
‘1’, ‘8’ and ‘0’
‘‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Cobalto C05300
Страница 12: ...Contents x Cobalto CO5300 Scanner NOTES ...
Страница 26: ...Setup 14 Cobalto CO5300 Scanner NOTES ...
Страница 44: ...Enter Exit Programming Mode Enable Character 32 Cobalto CO5300 Scanner NOTES ...
Страница 228: ...Enter Exit Programming Mode Plessey 216 Cobalto CO5300 Scanner NOTES ...
Страница 254: ...References 242 Cobalto CO5300 Scanner NOTES ...
Страница 260: ...Technical Specifications 248 Cobalto CO5300 Scanner NOTES ...
Страница 274: ...Standard Defaults 262 Cobalto CO5300 Scanner NOTES ...
Страница 278: ...Sample Bar Codes 266 Cobalto CO5300 Scanner NOTES ...
Страница 280: ...Keypad 268 Cobalto CO5300 Scanner 5 6 7 8 9 A B C ...
Страница 281: ...Product Reference Guide 269 D E F ...
Страница 282: ...Keypad 270 Cobalto CO5300 Scanner NOTES ...