NETWORK TYPE SELECTION
The network type depends on the application layout and installed
accessories.
Through the CBX500 several types of accessory Fieldbus Interface
Modules are available to connect to a Fieldbus as a Slave node.
The Net Type switch setting must match the Host Interface
accessory module being used.
For all CBX series connection boxes the Net Type selector switch
allows setting the ID-NET™ Slave type (Topology Role). This
setting must match the Master ID-NET™ Topology Role.
For CBX500 connection boxes the Net Type selector switch allows
setting the Fieldbus type.
Net Type Switch
0 = None (no network present)
1 = Ethernet IP
2 = Profibus
3 = DeviceNet
4 = Reserved
5 = Reserved
6 = Reserved
7 = Reserved
8 = ID-NET™ Slave Synchronized
9 = ID-NET™ Slave Multidata
Fieldbus Slave nodes (including Masters with an ID-NET™ sub-
network) should be set to the specific Fieldbus type (
Ethernet
,
Profibus
, etc.).
ID-NET™ Masters communicating with the Host through the main
serial interface and all other non network applications should be
set to
None
.
If BM100s are used for ID-NET™ Slaves this switch should be set
to the
Slave Synchronized
or
Slave Multidata
position depending
on the ID-NET™ network Topology Role.
NETWORK ADDRESS SELECTION
Figure 3 – Address Selection Switches
BM100 provides hardware network address selection for rapid
installation. These switch settings override software configuration
settings. Valid address selection depends on the network type:
Ethernet
The Ethernet address refers to the last three digits of the IP
address (i.e. 172.16.1.xxx). The valid selection range is from 000 to
255. Address selections outside of this range are not accepted by
the Fieldbus network.
Profibus
The valid selection range for the Profibus address is from 000 to
125. Address selections outside of this range are not accepted by
the Fieldbus network.
DeviceNet
The valid selection range for the DeviceNet address is from 00 to
63. Address selections outside of this range are not accepted by
the Fieldbus network. The x100 switch is ignored.
ID-NET™
The valid selection range for the ID-NET™ Slave addresses is
from 01 to 31. Address selections outside of this range are not
accepted by the ID-NET™ network. The x100 switch in this case
refers to the ID-NET™ baudrate.
BAUDRATE SELECTION
All the Fieldbus networks use the autobaudrate feature. This
means the reading devices automatically are set to use the
Fieldbus baudrate.
The Fieldbus baudrate cannot be set
through the BM100 switches
.
Figure 4 – ID-NET™ Baudrate Switch
When the BM100 is used for ID-NET™ network Slaves, the ID-
NET™ baudrate is selected through the baudrate switch and must
match the Master ID-NET™ baudrate. The settings are:
ID-NET™ Baudrate Switch
0 = 19200 Baud
1 = 38400 Baud
2 = 57600 Baud
3 = 125 kBaud
4 = 250 kBaud
5 = 500 kBaud
6 = 1 MBaud
7 = Reserved
8 = Reserved
9 = Reserved
WRITE PROTECTION LOCK
Figure 5 – Write Protection
A write protection switch is provided to protect configuration data
from being inadvertently overwritten. When this switch is in the lock
position, the Backup function is not available (data cannot be
written to the backup memory) and a diagnostic warning message
can be sent. The Restore function is available.
S/N LABEL
A duplicate Serial Number label is included in the BM100 package.
This label can be applied onto the outside of the CBX for quick
reference.
BM150 DISPLAY CONNECTOR
BM100 provides the flat cable connector for connection of the
BM150 Display and Keypad accessory for the CBX500.
When the BM150 accessory is used the Backup and Restore
functions are managed through the Display and Keypad and
therefore are disabled at the BM100 Backup/Restore button. The
BM150 has an extended menu which allows partial as well as
complete backup and restore functions.