A20 Hardware Guide
Configuring the Client
6-3
Datalogic Automation Inc.
6. Click OK when the Device is Rebooting dialog is displayed.
Configuring the Client
Be sure the client computer and camera are directly connected with an Ethernet cable.
Changing the client computer’s addresses: Windows 7
1. In the Start Menu, select Computer, Network, then click Network and Sharing Center.
2. Under "View your Active Networks," click Local Area Connection.
3. Click Internet Protocol Version 4 in the list, then click Properties.
4. On the Alternate Configuration tab, select User Configured.
5. Enter the desired IP address and Subnet Mask.
6. Click OK to close all the open dialog windows.
Changing the client computer’s addresses: Windows Vista
1. In the Start Menu, select Network, then click Network and Sharing Center.
2. For the Local Area Connection, click View Status.
3. Click Internet Protocol Version 4 in the list, then click Properties.
4. On the Alternate Configuration tab, select User Configured.
5. Enter the desired IP address and Subnet Mask. Remember, to be able to communicate with the Datalogic camera, a
client computer’s Subnet mask must correspond correctly to the camera’s IP mask, and the address must match the
camera’s address in the first three sets of numbers.
6. Click OK to close all the open dialog windows.
Changing the client computer’s addresses: Windows XP
1. In the Start menu, right click on My Network Places and select Properties.
2. Right click on Local Area Connections and select Properties.
3. On the General tab, select Internet Protocol (TCP/IP) and click Properties.
4. On the Alternate Configuration tab, select User Configured.
5. Enter the desired IP address and Subnet Mask. Remember, to be able to communicate with the Datalogic camera, a
client computer’s Subnet mask must correspond correctly to the camera’s IP mask, and the address must match the
camera’s address in the first three sets of numbers.
6. Click OK to close all the dialog windows.