background image

Settings

66

Skorpio™ X4

Tap OK to complete:

The new profile now appears in the WCU profile list:

Each EAP profile can be either "Pairwise Master Key Caching (PMK)"
or Opportunistic Key Caching (OKC). By default, OKC radio button is
enabled for each of WLAN profile.

Содержание 942500001

Страница 1: ...Skorpio X4 with Windows Embedded Compact 7 Rugged Mobile Computer with 1D 2D Imager User s Manual ...

Страница 2: ...any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publi...

Страница 3: ...dels 6 Out of the Box 9 General View 10 Front View 10 Back View 11 Top View 12 Bottom View 12 Accessories 13 Battery 17 Install the Battery 17 Charge the Battery 18 Charge with USB 18 Charge with the Single Slot Dock 19 Replace the Battery 21 SD Card 27 Install the MicroSD Card 27 Getting Started 29 Power On 29 Desktop Window 30 Taskbar 31 ...

Страница 4: ... 46 Clean Boot 47 LED Indicators 48 Settings 49 Control Panel 49 Data Capture Configuration 50 General Decoding Properties 51 Symbology Settings 58 Decoding Settings 60 WCU Wireless Configuration Utility 61 Create a New Profile 62 Edit a Profile 67 Delete a Profile 67 Connect to a Profile 68 Disconnect from a Profile 68 Browse Nearby Wireless Networks 69 Audio Settings 71 Audio 71 Volume Sounds 72...

Страница 5: ... 135 Command Line DXU Execution 138 Datalogic Desktop Utility 139 Administrative Options Admin tab 140 Locked Web Browser Options LockedWeb Tab 144 Status Icons Options Status Tab 149 Windows Controls Win Tab 150 AppSelector Options AppSelect Tab 152 App Selector Application Selector 155 Locked Web Browser 156 Locked Web Browser Special Metatags 158 General Metatag Comments 158 PAL and PAL Communi...

Страница 6: ...85 Connection to USB Peripherals 186 RS232 Connection 188 RS232 Dock Connection 188 WLAN Connection 189 WPAN Connection 190 Wireless and Radio Frequencies Warnings 192 Technical Features 195 Technical Data 195 Decode Distances 200 Skorpio X4 Imager 1D Linear CCD 200 Skorpio X4 Imager 2D 201 Test Codes 203 Maintenance 211 Cleaning the Device 211 Dock Contacts Cleaning Procedure 211 Ergonomic Recomm...

Страница 7: ...on for the User 228 FCC IC Labeling 229 FCC Compliance 229 ISED Compliance 231 Radiofrequency Radiation Exposure Information 233 Radio Technologies and Frequency Bands 234 Europe 234 US and Canada 235 WEEE Compliance 236 Reference Documentation 239 Support Through the Website 239 Technical Support through email or phone 239 Warranty Terms and Conditions 239 Glossary 241 ...

Страница 8: ...vi Skorpio X4 NOTES ...

Страница 9: ...ual uses the following conventions Mobile computer and Skorpio X4 refer to Skorpio X4 mobile computer Single Dock refers to the Skorpio X4 Single Slot Dock The label artworks may be only a draft Refer to the product labels for more precise information ...

Страница 10: ...tores in hyper stores and supermarkets convenience stores grocery or DIY Datalogic s Skorpio X4 mobile computer fits most any retail in store requirement for mobile data collection or validation And with the optional pistol grip this unit is also ready for the demanding back end receiving and warehousing environments as well The Skorpio X4 mobile computer is primarily used by the retail store asso...

Страница 11: ...further information regarding WEC7 refer to the website http www microsoft com windowsembedded Americas Models WEC7 Batch 1D 942500001 SKORPIO X4 000000TN0HN0W7 Skorpio X4 Handheld Batch 1GB RAM 8GB Flash 28 Key Numeric Green Laser like 1D Imager w Green Spot Windows Embedded Compact 7 942500002 SKORPIO X4 000000TN0HS0W7 Skorpio X4 Handheld Batch 1GB RAM 8GB Flash 38 Key Functional Green Laser lik...

Страница 12: ...C EC7 Wi Fi 2D Handheld 942550004 SKORPIO X4 00ANM4HS0HN0W7 Skorpio X4 Handheld 802 11 a b g n MIMO CCX v4 Bluetooth v4 1GB RAM 8GB Flash 28 Key Numeric White Illumination 2D Imager w Green Spot Windows Embedded Compact 7 FCC 942550005 SKORPIO X4 00ANM4HS0HS0W7 Skorpio X4 Handheld 802 11 a b g n MIMO CCX v4 Bluetooth v4 1GB RAM 8GB Flash 38 Key Functional White Illumination 2D Imager w Green Spot ...

Страница 13: ...oth v4 1GB RAM 8GB Flash 50 Key Full Alpha Numeric Green Laser like 1D Imager w Green Spot Windows Embedded Compact 7 FCC WEC7 Wi Fi 2D Pistol Grip 942600004 SKORPIO X4 00ANM4HS0GN0W7 Skorpio X4 Pistol grip 802 11 a b g n MIMO CCX v4 Bluetooth v4 1GB RAM 8GB Flash 28 Key Numeric White Illumination 2D Imager w Green Spot Windows Embedded Compact 7 FCC 942600005 SKORPIO X4 00ANM4HS0GS0W7 Skorpio X4 ...

Страница 14: ...mbedded Compact 7 WEC7 Wi Fi 1D Handheld 942550013 SKORPIO X4 E00ANM4TN0HN0W7 Skorpio X4 Handheld 802 11 a b g n MIMO CCX v4 Bluetooth v4 1GB RAM 8GB Flash 28 Key Numeric Green Laser like 1D Imager w Green Spot Windows Embedded Compact 7 EU 942550014 SKORPIO X4 E00ANM4TN0HS0W7 Skorpio X4 Handheld 802 11 a b g n MIMO CCX v4 Bluetooth v4 1GB RAM 8GB Flash 38 Key Functional Green Laser like 1D Imager...

Страница 15: ...ORPIO X4 E00ANM4HS0HF0W7 Skorpio X4 Handheld 802 11 a b g n MIMO CCX v4 Bluetooth v4 1GB RAM 8GB Flash 50 Key Full Alpha Numeric White Illumination 2D Imager w Green Spot Windows Embedded Compact 7 EU WEC7 Wi Fi 1D Pistol Grip 942600013 SKORPIO X4 E00ANM4TN0GN0W7 Skorpio X4 Pistol grip 802 11 a b g n MIMO CCX v4 Bluetooth v4 1GB RAM 8GB Flash 28 Key Numeric Green Laser like 1D Imager w Green Spot ...

Страница 16: ... 1GB RAM 8GB Flash 28 Key Numeric White Illumination 2D Imager w Green Spot Windows Embedded Compact 7 EU 942600017 SKORPIO X4 E00ANM4HS0GS0W7 Skorpio X4 Pistol grip 802 11 a b g n MIMO CCX v4 Bluetooth v4 1GB RAM 8GB Flash 38 Key Functional White Illumination 2D Imager w Green Spot Windows Embedded Compact 7 EU 942600018 SKORPIO X4 E00ANM4HS0GF0W7 Skorpio X4 Pistol grip 802 11 a b g n MIMO CCX v4...

Страница 17: ...Quick Start Guide Safety Regulatory Addendum Wavelink Avalanche Insert radio models only Wavelink Terminal Emulation insert pistol grip models only End User License Agreement EULA Sheet Remove all the components from their packaging check their integrity and compare them with all the packing documents CAUTION Keep the original packaging for use when sending products to the technical assistance cen...

Страница 18: ...Introduction 10 Skorpio X4 General View Front View ON OFF Power Key LEDs Receiver Speaker Color Display Front Scan Key Keyboard ...

Страница 19: ...Introduction User s Manual 11 Back View Laser Safety Label Micro USB Connector Loudspeaker Trigger Button for use with the optional pistol trigger Product Label Reset Key MicroSD Card Slot ...

Страница 20: ...Introduction 12 Skorpio X4 Top View Bottom View Data Capture Window HandyLink connector host device ...

Страница 21: ... Charge Only Dock recharges 4 terminals and 4 spare batteries Requires Power Supply 94ACC1385 94A150055 Multi Ethernet Dock recharges 4 terminals and 4 spare batteries Requires Power Supply 94ACC1385 94A150034 Multi Battery Charger recharges 4 spare batteries Requires Power Supply 94ACC1385 Power Supplies Cords 95ACC1113 Power Cord 120V AC IEC US 95ACC1213 Power Cord 240V AC UK 95A051041 Power Cor...

Страница 22: ...able 94A051969 Cable from Micro USB dock to female USB Device works as host 1m straight 94A051970 Cable from device Handylink to USB Device works as client Connects to PC 2m straight cable 94A051971 Cable from device Handylink to female USB Device works as host Connects to printers or most other peripherals 15cm straight cable 94A051972 Cable from device Handylink to female DB9 RS232 Null Modem Ca...

Страница 23: ...h all models of Skorpio X4 94ACC0045 Quick Release Belt Clip for Skorpio X3 X4 10 Pack it includes the bolt and the screw to be fixed to the device one is included with all the handheld models of Skorpio X4 94ACC0081 Lanyard to tether the Skorpio X3 X4 to the wrist it fits both Skorpio X3 X4 and Falcon X3 one is included with all the pistol grip models of Skorpio X3 X4 and Falcon X3 Holsters Cases...

Страница 24: ...ngth adjustable 94ACC1240 Shoulder strap 5 pcs 94A150041 Vehicle Holder for Skorpio X3 X4 it includes two screws and relevant washers for RAM Mount does not include the RAM Mount itself 94ACC0075 RAM Mount for Vehicle Holder it fits both the vehicle holders for Skorpio X3 X4 and Lynx CAUTION Use only a Datalogic approved power supply and cables Use of an alternative power supply will invalidate an...

Страница 25: ...User s Manual 17 Battery Install the Battery To install the battery pack insert the battery s alignment lugs into the recesses then press firmly until the battery latch clicks twice ...

Страница 26: ...nce the charging process has been completed the charging LED glows green constantly The charging LED flashes red when a charging error is detected Charge with USB You can use a standard micro USB to USB cable in conjunction with a power supply adapter to charge the Skorpio X4 from a power outlet The Micro USB port can also be used to charge the Skorpio X4 battery pack from any self powered USB hub...

Страница 27: ... an additional battery pack by inserting it into the rear slot of the dock NOTE The Skorpio X4 may get warm during charging this is normal and does not mean a malfunction CAUTION By default the battery pack is disconnected at the factory to avoid damage due to excessive draining ...

Страница 28: ...onomy varies according to many factors such as the frequency of barcode scanning RF usage battery life storage environmental conditions etc Close to the limits of the working temperature some battery performance degradation may occur CAUTION The Skorpio X4 should be charged at an ambient temperature between 0 35º C 32 to 95 ºF to achieve the maximum charging rate Never charge the device battery in...

Страница 29: ...ce the Battery To replace the battery pack follow the steps below 1 Turn off the Skorpio X4 press the power key and wait for device power off 2 Press the latch release button and pull the battery latch down 3 Remove the battery pack ...

Страница 30: ...horities WARNING Use only Datalogic approved batteries and accessories for battery charging Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Il y a risque d explosion si la batterie est remplacée par une batterie de type incorrect Mettre au rebut les batteris usagées confor mément aux instructions NOTE Even if the storage tempera...

Страница 31: ...duction cook surfaces or similar devices Doing so may cause the battery pack to generate heat explode or ignite Using the battery pack in this manner may also result in a loss of performance and a shortened life expectancy To power the cradle use only a Datalogic approved power supply The use of an alternative power supply will void the product warranty may cause product damage and may cause heat ...

Страница 32: ...ith nails strike it with a hammer step on it or otherwise subject it to strong impacts pressures or shocks Do not disassemble or modify i e bend crush or deform the battery pack The battery pack contains safety and protection devices which if damaged may cause the battery pack to generate heat explode or ignite In case of leakage of liquid from the battery avoid contact with liquid the skin or eye...

Страница 33: ...pack when the device is turned on Do not remove or damage the battery pack s label Do not use the battery pack if it is damaged in any part Battery pack usage by children should be supervised Collect and recycle waste batteries separately from the device in compliance with European Directive 2006 66 EC 2011 65 2002 96 EC and subsequent modifications with US and China regulatory laws and regulation...

Страница 34: ...Battery 26 Skorpio X4 NOTES ...

Страница 35: ...cards To access the microSD card slot and insert the card follow the steps below 1 Turn off the Skorpio X4 2 Remove the battery pack see Replace the Battery on page 21 steps 1 to 3 3 Shift the cardholder upwards and then pull it up 4 Insert the microSD card with the written part upward ...

Страница 36: ...s slot CAUTION Follow proper ESD precautions to avoid damaging the microprocessors in the Skorpio X4 or the microSD card itself Proper ESD precautions include but are not limited to working on an ESD mat and ensuring that the operator is properly grounded Do not force the card If you feel resistance remove the card check the orientation and reinsert it Do not use the microSD card slot for any othe...

Страница 37: ... the screen Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure The mobile computer goes into power off low power with display and keyboard backlight off when it is not used for more than a programmable timeout which can be defined in the Power applet of the Control Panel In this mode it can be awakened by the ON OFF key NOTE The mobile compu...

Страница 38: ...ow As soon as the mobile computer is on the Windows Embedded Compact 7 desktop appears on the screen Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure Windows Embedded Compact 7 Desktop ...

Страница 39: ...let you disconnect the ActiveSync session without physically disconnecting the device from the PC It is the only way to disconnect a Bluetooth ActiveSync connection Battery icons display the system battery status Bluetooth Manager icon displays whether Bluetooth is enabled paired or turned off Double tap this icon to open the Bluetooth Manager control panel applet Network connectoid icon displays ...

Страница 40: ...able for that item On the pop up menu that appears tap the action you want to perform CAUTION Use only original Datalogic styluses supplied with the product itself In harsh applications use of screen protectors should be taken into consideration in order to extend the touch screen operating life To prevent damage to the screen do not use sharp devices or any device other than the Datalogic provide...

Страница 41: ...ollowing a clean boot a Welcome Wizard with Stylus Calibration comes up Also you might need to recalibrate the touch screen i e when you attempt to select an item with the stylus another item is erroneously selected To recalibrate the touch screen following the steps below 1 Tap Start Settings Control Panel Double tap the Stylus icon to open the Stylus Properties window ...

Страница 42: ...rate 2 Carefully press and briefly hold the stylus on the center of the target Repeat as the target moves around the screen 3 By completing the calibration procedure you implicitly accept the new calibration settings 4 The new calibration settings are persistently saved in the Registry ...

Страница 43: ...es with three different keyboards a full alphanumeric keyboard having 50 keys an alphanumeric keyboard having 38 keys and a numeric keyboard having 28 keys A 28 keys functional keypad is also available for special configurations Full alphanumeric Keyboard 50 Keys ...

Страница 44: ...r toggle key when pressed before a standard key it enables the character or function printed in yellow above the key Blue modifier one shot key when pressed before a standard key it enables the character or function printed in blue above the key The ON OFF Power button powers the Skorpio X4 ON or OFF It is placed on the upper left side of the terminal Icon Function After a Blue modifier key press ...

Страница 45: ...Getting Started User s Manual 37 Alphanumeric Keyboard 38 Keys ...

Страница 46: ...ndard key it enables the character or function printed in yellow above the key Blue modifier one shot key when pressed before a standard key it enables the character or function printed in blue above the key The ON OFF Power button powers the Skorpio X4 ON or OFF It is placed on the upper left side of the terminal Icon Function After a Blue modifier key press the Start menu key opens the Start men...

Страница 47: ...Getting Started User s Manual 39 Numeric Keyboard 28 Keys ...

Страница 48: ...ards within text fields scroll through a Menu list or browse among folder files Yellow modifier toggle key when pressed before a standard key it enables the character or function printed in yellow above the key Blue modifier one shot key when pressed before a standard key it enables the character or function printed in blue above the key The ON OFF Power button powers the Skorpio X4 ON or OFF It i...

Страница 49: ... keys key 0 excluded and the ESC key share the following behavior scheme A Function of the key when directly pressed B Modified by the Yellow key repeated presses cycle through the letters shown on the keyboard overlay for each key The letter is entered if you wait for a short timeout ...

Страница 50: ...Getting Started 42 Skorpio X4 Functional Keyboard 28 Keys Only available on WEC7 special configurations ...

Страница 51: ...gh a Menu list or browse among folder files Yellow modifier toggle key when pressed before a standard key it enables the character or function printed in yellow above the key Blue modifier one shot key when pressed before a standard key it enables the character or function printed in blue above the key The ON OFF Power button powers the Skorpio X4 ON or OFF It is placed on the upper left side of t...

Страница 52: ...eys key 0 excluded and the Period key share the following behavior scheme A Function of the key when directly pressed B Modified by the Yellow key repeated presses cycle through the letters shown on the keyboard overlay for each key The letter is entered if you wait for a short timeout ...

Страница 53: ...Overlay To insert the terminal emulation overlay proceed as follows 1 Remove the overlay using a torx screwdriver 2 Insert the terminal emulation overlay first the upper side Fix the overlay with the screwdriver Always use a torx screwdriver to prevent screw damage ...

Страница 54: ...erved The Registry is restored from persistent memory A clean boot restores the Skorpio X4 to a clean configuration both the Registry and the file system returns to a clean status that conforms to factory default Warm Boot To perform a warm boot press and hold the following keys simultaneously Cold Boot To perform a cold boot do the following steps 1 Turn off the Skorpio X4 by pressing the ON OFF ...

Страница 55: ... down the Esc 0 keys simultaneously promptly after resetting A dialog box will appear asking for confirmation Press the Enter Key Warm Boot Cold Boot Clean Boot Registry Restored from flash Restored from flash Cleanconfiguration no user config File System Preserved Clean Installation except for FlashDisk folder Clean Installation no user files ...

Страница 56: ...king amber when the device raises a notification to the user Keyboard LED center Off Keyboard in primary Yellow Constant Yellow alternate key mode Blue Constant Blue alternate key mode Pink CapsLock enabled Good Read LED right side The Good Read LED has also a Suspend LED feature The decode LED will glow red when the device begins to suspend and will turn off when the suspend completes successfull...

Страница 57: ...User s Manual 49 Settings Control Panel From the Start menu tap Settings Control Panel Below is an expanded view of the Control Panel showing all of the applets ...

Страница 58: ...ll settings for the scanner From the control panel main window double tap the Decoding icon Tap Configure and select General 1D barcode or 2D barcode then use the menu or tap the left and right arrow keys to navigate the different pages of the Decoding Properties window The menu options will change to reflect the items most recently selected ...

Страница 59: ...nd select the desired configuration from the options shown in the figure below Notification Use it to set the number the duration and the interval of notifications LED green spot beep or vibration the scanner emits on a good read You can also set the volume and tone of the beeps ...

Страница 60: ...t the maximum amount of time the scanner attempt to decode after the scan key or the trigger is pressed Formatting Allows to format the barcode text by enabling and configuring the use of prefix suffix and data separator Scroll the Add special drop down list to select a special character to be added in the current cursor position ...

Страница 61: ... the beginning of the decoded barcode DL ID is a Datalogic specific character identifier User ID is a user specific character identifier you can set in the related symbology settings menu Group Separator replacement is a non printable data separator character ASCII code 1D hex Scroll the Group Separator replacement drop down list to select a string that will be used as GS data separator substituti...

Страница 62: ...orpio X4 Decoding Options Use it to configure the User ID for symbologies Redundancy and Aggressive Decoding if supported by the decoding module Select a symbology to view or change the available properties settings ...

Страница 63: ...isplay It improves capability to read barcodes from LCD screen e g displayed on smartphone display Enable picklist If selected it allows you to pick and decode a barcode from multiple barcodes printed close together when the scan illumination intersects more than one barcode Only the targeted barcode will be returned Target mode If enabled when the scan button is pressed the scanner will project a...

Страница 64: ... a programmable time upon pressing the scan button Drag the Timeout slider to set the maximum amount of time the scanner attempt to decode after target timeout Release Scan Scanning takes place after the scan button is released Drag the Timeout slider to set the scanning timeout after releasing the scan button Enable target after aiming It enables aiming before scanning ...

Страница 65: ...evice goes on scanning until the number of Labels for good read is reached Select Enable indicators for each label to get an intermediate notification for each label decoded Keyboard Wedge Use it to enable or disable the keyboard wedge for barcode scanner ...

Страница 66: ...logy Settings Each barcode symbology can be customized with additional settings that may affect that specific barcode decoding Tap Configure and use the 1D barcode 2D barcode drop down menus to configure symbology decoding options ...

Страница 67: ...mbology control panels for examples of the types of fields and options you can modify The sample below shows the settings of a Code 128 barcode symbology Tap the left and right arrow keys to navigate the different pages of the barcode symbology pages ...

Страница 68: ...us configurations and or other available default settings The settings are saved when you tap Yes Any change you make is temporary and will be lost when the system restarts To save these settings to a persistent storage you need to save the Registry using the Persistent Registry applet in the Control Panel ...

Страница 69: ...ration Utility Wireless Configuration Utility WCU is a user mode application that provides an interface for configuring and operating an installed wireless network interface card wireless adapter Tap Start Programs WLink WCU to open the WCU screen ...

Страница 70: ...e Security Type No Authentication Open Open authentication allows any device to authenticate and then attempt to communicate with the access point Using open authentication any wireless device can authenticate with the access point but the device can communicate only if its Wired Equivalent Privacy WEP keys match the access point s WEP keys ...

Страница 71: ...access point The device that is requesting authentication encrypts the challenge text and sends it back to the access point If the challenge text is encrypted correctly the access point allows the requesting device to authenticate To create a profile with PSK authentication follow the steps below 1 Select the Security Type as WPA2 Personal 2 Select the Encryption Type 3 Enter the password in the S...

Страница 72: ... WEP key to the access point which uses the key for all unicast data signals that the server sends to or receives from the client The access point also encrypts its broadcast WEP key which is entered in the access point s WEP key slot 1 with the client s unicast key and sends it to the client To create a profile with EAP authentication follow the steps below 1 Select the Security Type as WPA2 Ente...

Страница 73: ...Settings User s Manual 65 4 Tap the User Credentials tab to enter the EAP methods user credentials 5 Tap the Authentication tab to select the EAP inner method ...

Страница 74: ... OK to complete The new profile now appears in the WCU profile list Each EAP profile can be either Pairwise Master Key Caching PMK or Opportunistic Key Caching OKC By default OKC radio button is enabled for each of WLAN profile ...

Страница 75: ...gs User s Manual 67 Edit a Profile Select a profile in WCU profile list and tap Edit on the navigation menu bar Delete a Profile Select a profile in WCU profile list and tap Delete on the navigation menu bar ...

Страница 76: ...ile list and tap Connect on the navigation menu bar Tap the Status tab to display the connection status Disconnect from a Profile Select a connected profile in WCU profile list and tap Disconnect on the navigation menu bar Tap the Status tab to display the connection status ...

Страница 77: ...ct a network from the list Depending on whether or not the adapter network is connected to that network the Connect or Disconnect button on the menu bar will be enabled 2 Tap Connect or Disconnect 3 WCU initiates the Create New Profile dialog box if the profile doesn t exist already 4 Enter a profile name or leave the default name 5 Select Security Type and Encryption Type settings for the new pro...

Страница 78: ...Settings 70 Skorpio X4 Refresh Tap Refresh to manually refresh the scan list Each click on this button triggers a scan request to driver ...

Страница 79: ...o Settings There are two applets that control volume Audio and Volume Sounds Audio The Audio Properties window allows to set the volume for the speaker and the microphone From the control panel main window double tap the Audio icon ...

Страница 80: ...Settings 72 Skorpio X4 Volume Sounds From the control panel main window double tap the Volume Sounds icon The Volume Sounds applet configures audio features of all speakers and headphones ...

Страница 81: ...Bluetooth To turn the Bluetooth on 1 Double tap the Bluetooth Manager icon from the Control Panel window 2 Tap Settings The Settings tab allows you to enable or disable the Bluetooth radio and specify settings for Incoming Connections Select Enable Bluetooth Radio NOTE By default Bluetooth is turned off If you turn it on and then turn off your device Bluetooth also turns off When you turn on your ...

Страница 82: ...rtual COM port to use for the connection 4 Tap Find Me if you want to make the Skorpio X4 discoverable to other Bluetooth devices for 60 seconds allowing them to set up a connection Tap OK on the Find Me pop up window 5 Tap Apply 6 Once the Bluetooth radio is enabled the terminal automatically starts searching for discoverable devices ...

Страница 83: ...e type of device you want Printer Serial or All or tap Discovery Discover to skip this step The Skorpio X4 will search for Bluetooth devices within range NOTE If you attempt to set up a connection when the Bluetooth radio is disabled you will receive a message reminding you that the radio is turned off and asking if you want to turn it on Tap Yes if you need to enable the Bluetooth radio ...

Страница 84: ...Settings 76 Skorpio X4 Icon Service Dialup Networking Printer Object Push OPP Object Exchange OBEX ActiveSync Human Interface Device HID Keyboard Serial Personal Area Network PAN Modem Headset Handsfree ...

Страница 85: ...on and then tap Connect 4 Select a service and configure any encryption authentication or virtual port options required by the service selected Virtual Port allows you to specify the incoming port which is used to communicate serially with an incoming device just as if it were a physical COM port This option is available only if you have selected a Printer or Serial service ...

Страница 86: ...est dialog box will request that you enter a PIN Use the Input Panel or the keyboard to type the PIN Tap OK to complete The dialog box will also appear when an authentication request is received from another device NOTE You can also select Encrypt or Authenticate from the Settings tab of the Bluetooth Manager control panel ...

Страница 87: ...the Connections tab Use the Virtual Port drop down menu to change the Virtual Port Tap Sync to initiate a Sync available only if the service is an ActiveSync connection Tap Delete to remove the device pairing 1 Tap Settings Bluetooth 2 Select a device from the Paired Devices list and tap the settings icon next to its name The Paired Bluetooth device window displays on the screen ...

Страница 88: ...r applications and hardware devices The Registry also contains information that the operating system continually references to during operation To persist the Registry settings between boots follow the steps below 1 From the Control Panel main window double tap the Persistent Registry icon 2 Tap Persist 3 Tap OK to exit ...

Страница 89: ...timing 1 From the Persistent Registry window select a time interval from the menu 2 Tap OK to save and exit To cancel the Persistent Registry timing 1 From the Persistent Registry window deselect the Persist Registry settings check box 2 Tap OK to save and exit ...

Страница 90: ...Settings 82 Skorpio X4 NOTES ...

Страница 91: ...he DL Buttons tab Customize the program hardware buttons to launch your most used applications Use the Select a button drop down menu to select the button you want to assign a function to and then select an application from the Assign a function drop down menu Command Description Select a Button This drop down list shows the available function keys to define Select the desired one from the list Ne...

Страница 92: ...n This drop down list shows the available functions Application Displays the path to the selected application Browse Tap to browse for application files You can associate an executable program with the specified button Arguments Type the command line arguments that are needed for the specified application This option is only available when Launch Application is selected from the Assign a function ...

Страница 93: ...nter the desired key combination 3 Tap OK to save the new button Tap X to cancel NOTE Make sure you do not attempt to add a button that is already defined CAUTION The keyboard wedge can activate assigned buttons using alphanumeric characters Barcodes containing characters associated with assigned buttons will trigger the action or application assigned to that button ...

Страница 94: ... 86 Skorpio X4 Triggers Triggers are special customizable buttons that are mapped by default by DL Buttons Also they can be set as wakeup buttons Triggers Available Functions Scan barcode activates the scanner Pistol Trigger ...

Страница 95: ...s open applications The application switcher is activated via an assigned shortcut key specified in the DL Buttons tab see Persistent Registry on page 80 When the assigned button is pressed the dialog box below is displayed Press the assigned button to cycle through the running applications when the dialog box is open Press Enter to switch to the selected application or Esc to close the applicatio...

Страница 96: ...ouch screen and the keyboard interfaces such as NFC Wi Fi Bluetooth USB and Ethernet device settings such as date time time zone and power management and security settings such as password access DXU can also configure communication parameters between the application that runs on a PC and the client applications that run on the device DXU offers a method to print out barcodes that Skorpio X4 users...

Страница 97: ...nvenient UI to configure the Skorpio X4 An application runs continuously on the device to extract current configuration settings and send them to the DXU desktop application and to receive updated settings from the DXU desktop application and apply those configuration settings to the device DXU configurations are stored as configuration files on the PC and are transmitted to and from the Skorpio X...

Страница 98: ...Windows Vista family DXU is supported on both 32 bit and 64 bit versions of Windows Vista Windows 7 family DXU is supported on both 32 bit and 64 bit versions of Windows 7 Windows 8 family DXU is supported on both 32 bit and 64 bit versions of Windows 8 Windows 8 1 family DXU is supported on both 32 bit and 64 bit versions of Windows 8 1 Windows 10 family DXU is supported on both 32 bit and 64 bit...

Страница 99: ...systems but it can be disabled by default If you do not see this prompt UAC may have been disabled 4 Follow on screen prompts to finish installing DXU 5 Follow on screen prompts to finish installing Datalogic Device Support drivers Controls DXU Agent Controls DXU settings on the device can be configured with the DXU control panel The following options are available in the DXU control panel 1 Deskt...

Страница 100: ...ton to broad case UDP packets to automatic discovery of device by DXU Desktop 3 Enable service when enabled DXU Agent on the device will function Requires a warm boot for change to take effect Version This page displays the DXU Agent version number ...

Страница 101: ...themselves to DXU either when they connect via USB or when they connect over a network Simply connecting the Skorpio X4 to a network even on the same subnet as the PC running DXU will not automatically display as being available The device must try to connect to DXU which sends an announcement packet to DXU This can be done by scanning Scan2Deploy barcode labels However connecting a device to the ...

Страница 102: ...tomatic display of devices as they connect and it can remove devices from the list that are not currently connected Add Device This button opens the Add Device dialog box which allows you to type the IP address of a device This dialog box does not support DNS naming of devices You can also use a custom TCP port if you have configured your device to use one in DXU Agent For convenience this field p...

Страница 103: ...expert for more information Once connected devices that respond to DXU s query over the network will display in the Available Devices list Load Configuration Clicking the Load Configuration button opens a standard file dialog box that allows you to explore for and select a DXU configuration file Loading a configuration allows you to edit a device s configuration when the device is not connected to...

Страница 104: ...ocated then select any configuration file you wish You can double click it to streamline opening it 3 Click the Open button Note that the default location is your user directory on your PC but DXU remembers the last directory you opened a DXU configuration file and always starts in that directory the next time you wish to open another DXU configuration file ...

Страница 105: ...rcode must be generated and printed using the Scan2Deploy button on DXU desktop Manifest File Manifest Files are text ini files indicating which firmware versions to update devices to update tag which DXU configuration file to apply config tag and which apk Android and cab WEC7 file applications to install install tag It is recommended that update tags be in separate manifest files You can specify...

Страница 106: ...XU Server PC name of app2 to install file with full path on DXU Server PC name of appN to install file with full path on DXU Server PC config name of DXU configuration file file with full path on DXU Server PC WEC7 Example update firmware img install install cab C Users DLUser Documents Wec7 auto_sync cab config defaultConfigWec7 dxu C Users DLUser Documents Wec7 my_user dxu ...

Страница 107: ...e a Scan2Deploy barcode label This button opens the Scan2Deploy dialog box streamlined to create Scan2Deploy labels that can automatically connect a device to a Wi Fi access point on your PC s subnet and to automatically connect it to DXU adding it to DXU s Available Device list Printing a Simplified Deploy Barcode By embedding the IP address of the PC where DXU desktop is installed the security i...

Страница 108: ...ich has DXU desktop installed and the name of the manifest file to be used You can also create a New manifest file as a template for either DXU configuration file or a firmware update file You could then edit the Manifest File ini file in a text editor like Word Pad to add applications to install 4 Click the Print Preview button enlarging the barcode view as needed And then print by clicking the u...

Страница 109: ...a device configuration to devices which don t have network access to DXU on your PC When the Include Unmodified Changes checkbox is selected all configuration items will be included in the barcode set This option results in several barcodes being generated as true Scan2Deploy labels After scanning the first label in this set DXU Agent s Scan2Deploy window on your device will display how many barco...

Страница 110: ...n tab which allows printing barcodes to configure the device without the need of the PC with DXU desktop being accessible from the Wi Fi network Wi Fi Configuration Tab Barcode Type Menu The Barcode Type menu allows you to choose which barcode symbology that Scan2Deploy labels will be printed in Each barcode symbology has advantages and disadvantages which may benefit your organization ...

Страница 111: ...ialog box s fields Save Button You may save Scan2Deploy labels as graphic files should this prove convenient for including Scan2Deploy barcodes in an e mail to a remote office for example Wi Fi Configuration Controls As with the other version of the Scan2Deploy dialog box this group of controls allows you to configure the automatic configuration of a device s Wi Fi connection Fields allow you to e...

Страница 112: ...dialog box this tab allows to set the maximum size of each label by symbology For example if you know that your devices can scan larger 2D labels than DXU s default setting you can increase the size of your label so fewer labels are needed to fully deploy your configuration Settings Window The Settings window is opened by clicking the Settings button on DXU main window This view includes controls ...

Страница 113: ...DXU uses to communicate several types of information with remote computers that are being configured The Desktop UDP Server Port a and the Device UDP Server Port b fields must be set to the same value as the matching ports on the remote device to ensure communication and remote configuration The Device HTTP Server Port c field must be set to the same value as the matching ports on the remote devic...

Страница 114: ...he types of settings include scanner settings enterprise settings system configuration settings DXU Agent configuration settings SoftSpot settings Tap2Deploy device side settings and SureLock settings Other settings may be added in the future Additional settings may be available depending on hardware options installed on your device and may depend on software installed on your device Device Info B...

Страница 115: ... the screen of the device you are currently connected to This window also includes buttons to remotely activate the devices external buttons and to capture a screen shot of what is visible on its screen Firmware Update Utility Button Clicking this button opens the Firmware Utility dialog box which you can use to update the firmware on your device ...

Страница 116: ...ee Printing Custom Configuration Barcodes on page 101 Use it to create Scan2Deploy barcode sets that can fully configure a device without network access to DXU on your PC containing all configuration settings in one set of barcodes and applying them by scanning the labels all without the need to use Simplified Deploy ...

Страница 117: ... Manually If DXU Agent on the device has its Enable Discovery Manager feature enabled and DXU has Automatic Discovery of Devices enabled under Advanced Settings then clicking Refresh should display it in the Available Device list if it is in the same subnet However if you want to manually add a device in DXU make sure both device and system are in the same subnet and follow these steps 1 From the ...

Страница 118: ...steps below 1 Launch DXU 2 Click Scan2Deploy on the DXU main window 3 Enter the SSID and Password for the Wi Fi access point that your device will use to connect to your network 4 Click Print Preview NOTE You will see the IP Address and port details displayed on the DXU main window along with the model name serial number and an illustration of the device NOTE You can also directly connect the devi...

Страница 119: ...art menu Programs Device Tools Scan2Deploy 8 Scan the barcode Your device should appear in the Available Device list of the DXU main window Click Available Device to continue configuring your device Delete a Device from the Available Device List Click the exit button X located at top right of the device NOTE Scan to Configure also under Device Tools allows you to configure a Wavelink Avalanche bar...

Страница 120: ...le name in the field or you can click the Browse button to use a standard file dialog box to explore to the folder of your choice and type the file name Unusually clicking the Save button in the Save As dialog box does not actually save the configuration file but returns you to the Save Configuration dialog box 3 Optionally you may select the Use Password check box and type a password into the fie...

Страница 121: ... the Load Configuration file This will open a standard file dialog box 3 Explore to your configuration file select it and click Open Open a Configuration File Which is Authenticated DXU displays a login prompt when you open a configuration file that requires authentication and when you connect to a device with a password set in the DXU Agent ...

Страница 122: ...n the Password field 4 Click OK Edit a Configuration File Off line You can edit configuration files even when the device they were drawn from are not connected to DXU Follow the steps below 1 Open your configuration file 2 Edit any settings you wish 3 Either save the result to a new configuration file or just save to the same configuration file Add Comments to Configuration Settings Comments can b...

Страница 123: ...Device 3 Right click any tab node or parameter then select Add comment in the context sensitive menu 4 Type your comment 5 Click OK save A small text balloon will appear next to the item you commented on To edit a comment 1 Right click any item with a small comment icon 2 Select Edit comment in the context sensitive menu 3 Edit your comment 4 Click OK to save ...

Страница 124: ...s add them 4 Click Show Comments in the button bar You can select and edit comments in this table by double clicking the Comment field Click the exit button X to close the dialog box Configure a Device On line Once you have added the device to Desktop Configuration Utility you can click ist name under the Available devices list and use the Configure This Device option to start configuring the devi...

Страница 125: ...e selects the barcode symbology used to print the Scan2Deploy labels Different symbologies have advantages and disadvantages so DXU gives you a choice 2 Include Unmodified Changes when you configure a device using the console you don t always wish to configure all the settings so by default the generated codes for configuration do not include unmodified settings However once selected the Include U...

Страница 126: ...bel set 1 Open a configuration file or load the configuration from a connected device 2 Click Configure This Device 3 Configure any settings you wish 4 Optional Save your configuration 5 Click the Back button to return to the Desktop Configuration Utility window 6 Click the Scan2Deploy 7 Click the Device Configuration tab 8 Optional Select the Include Unmodified Changes check box to include all co...

Страница 127: ... the Scan2Deploy barcodes 1 Resume your device and unlock its screen 2 Launch the DXU Agent application 3 Tap Menu and then select the Scan2Pair command 4 Scan any label in your Scan2Deploy label set 5 Continue to scan all the barcodes on the list Once the last label is scanned the configuration will be put into effect and an on screen notification will confirm that your configuration is complete ...

Страница 128: ...ault but you can also select Italian Chinese Simplified or Chinese Traditional To change DXU s language 1 From the DXU main window click Settings 2 Select the language you prefer in the Language menu 3 Click the Back button a leftward pointing arrow in a circle to return to DXU main window Configure DXU Communication Settings You can configure the TCP IP ports used by DXU to communicate with the D...

Страница 129: ...erver running on the console PC It is set to UDP port 3453 by default b The Device UDP Server Port configures the UDP port for the DXU Agent server running on the device It is set to UDP port 3453 by default c The Device HTTP Server Port configures the TCP port for the DXU Agent server running on the device It is set to TCP port 80 by default like common web servers d The Device VNC Server Port co...

Страница 130: ...PC DXU can log its activities and this can be very helpful for technical support to help you diagnose those unexpected problems that always seem to pop up after software is released to actual users Logging is not enabled by default Once enabled the DXU s default log file location is stored in your user directory at the following path C Users user AppData Roaming Datalogic DXU To enable logging 1 F...

Страница 131: ... Click Yes to confirm 5 Click the Back button a leftward pointing arrow in a circle to return to the DXU main window Create Scan2Deploy Labels to Fully Configure Remote Devices The Scan2Deploy button in the Datalogic Configuration Utility window can automatically connect devices to Wi Fi access points and to DXU Also the Scan2Deploy window has a further tab which allows you to include configuratio...

Страница 132: ...l apply the configuration changes automatically as if you had connected to DXU to transfer the changes To create Scan2Deploy barcodes that can completely configure your device 1 Open a configuration file or load the configuration from a connected device 2 Click Configure This Device 3 Configure any settings you wish 4 Optional Save your configuration 5 Click Back to return to the Desktop Configura...

Страница 133: ...r and complete using your printer s Print dialog box To apply the configuration by scanning the Scan2Deploy barcodes 1 Resume your device and unlock its screen 2 Launch the DXU Agent application 3 Tap Menu and then select the Scan2Pair command 4 Scan any label in your Scan2Deploy label set NOTE This option will increase the number of barcode labels in the Scan2Deploy label set NOTE This option wil...

Страница 134: ...prise SDK To view information about the device you are connected to 1 Load the configuration from a connected device 2 Click Device Info 3 Click the Back button a leftward pointing arrow in a circle to return to the DXU main window View Device Info Recorded in a Configuration File You can view information about the device from which a configuration file was extracted This information includes the ...

Страница 135: ... screen of a connected device This window also includes buttons to remotely activate the device s external buttons and to capture a screen shot of what is visible on its screen Note that clicking a button on screen does not physically press a button or even trigger it electrically but sends an event message to the system as if you had pushed a physical key or tapped a physical button on the touch ...

Страница 136: ...dow 6 Click the lock icon and drag it rightward releasing it over the unlocked lock icon at the right edge of the Remote Control window 1 Home Button At the bottom of the Remote Control window the Home button activates the device s Home button which switches the display to the Home screen 2 Menu Button At the bottom of the Remote Control window the Menu button activates the device s menu Not all t...

Страница 137: ... scanner as if you had pressed one of the Scan keys on the device There are some limitations the scanner will not scan if there is no application running that can receive its data the Camera application is showing its live preview or taking a photograph or recording a video none of the device s scan buttons are configured to scan However if your device is configured to scan barcodes and an applica...

Страница 138: ...and control your device This field is blank by default To set or edit a VNC password in DXU Agent 1 Resume your device and unlock its screen 2 Launch the DXU Agent application 3 Tap Menu to display the menu 4 Tap the Settings button 5 Clear the Enable Service check box 6 Tap the Password button in the VNC Settings section 7 Type a password in the field It can be numbers letters or some punctuation...

Страница 139: ...assword in the field and then click OK Set or Edit the VNC Authentication Password from DXU You can change a device s VNC password from DXU It is a configuration parameter in the Device Configuration window Follow the steps below 1 Open a configuration file or load the configuration from a connected device 2 Click the Configure This Device 3 Click the DXU Configuration tab 4 Click the General Sett...

Страница 140: ...ithout performing an update NOTE DXU firmware update is not the only way to update the firmware on the Skorpio X4 DXU s firmware update capability works only with connected devices If you need a method that can update firmware on many devices remotely especially if they are not connected to a network then other methods may suit your needs better Please consult your device s user reference guide fo...

Страница 141: ...re image can become corrupted in the field and this option allows a DXU administrator to perform a full firmware upgrade disregarding the version reported by the device Factory Data Reset After Installing Firmware A factory data reset is a full reset of the device intended to return it to factory defaults This reset deletes all user data settings and installed applications and resets the device s ...

Страница 142: ...file dialog box to browse for and select a suitable firmware image file 6 Navigate to your firmware image file select it and click Open Optional Select the Silent Install check box if you wish to perform a firmware update that does not require user interaction on the device Optional Select the Force Update check box if you wish to force a complete reinstallation of this image on the device Optiona...

Страница 143: ...hese settings when creating a DXU configuration file 1 The EULA on the device must first be accepted This can be performed by first launching SureLock or SureFox on the device and accepting the EULA Future versions of DXU Desktop will allow you to remotely accept this EULA just once for your entire installation 2 The Enable SureLock Password and or Enable SureFox Password fields must have the curr...

Страница 144: ...Datalogic Applications 136 Skorpio X4 SureFox ...

Страница 145: ...Datalogic Applications User s Manual 137 Change the SureLock and or SureFox Password After completing the above steps you can enter the new password in the Change Password field SureLock SureFox ...

Страница 146: ...been connected to the Wi Fi network Optionally you can perform Simplified Deploy with a manifest file without using Scan2Deploy Usage DXU command line options are DXU put filename dxu Applies configuration file to any USB connected devices DXU put filename dxu ip ipaddress Applies configuration file to device of specific IP address DXU man filename ini Applies Simplified Deploy to any USB connecte...

Страница 147: ...he desktop with a selection of authorized applications Restrict user access in Internet Explorer Set up configuration and customized error recovery mechanisms Create quick access hot keys and configure trigger actions To open the DDU double tap the DDU icon on the Control Panel You can also open the DDU by pressing the appropriate key shortcut The default is Alt 6 NOTE You can change the key combi...

Страница 148: ...ess Restrictions and Application Selector Enter password Allows to specify a password when this utility is launched Re enter password Re enter the password for confirmation Set Password Tap to enable the password Set Defaults Tap to reset the default values of all the functions on all the tabs After you select this option you will receive a prompt to verify this selection ...

Страница 149: ...ord can consist of all standard keyboard characters 2 Re enter the password in the second text box 3 Tap Set Password to enable the password 4 Tap OK to close the Password Set dialog box NOTE Be sure to record the Password for future reference NOTE Tap Set Password before exiting DDU in order to store and activate your new password It is not necessary to select Enable Datalogic Desktop ...

Страница 150: ...t box 3 Tap Set Password Remove a Password To remove a password 1 Enter blank in both password fields 2 Tap Set Password Password Request Dialog Box Once the password is set the next time you launch the Datalogic Desktop Utility the DDU password dialog box opens CAUTION Set Defaults removes all custom settings and restore all the factory default settings except a previously set password ...

Страница 151: ... Type in your password using either the keypad on the unit or using the stylus on the soft input panel SIP If you enter an incorrect password the system will prompt you to input the correct one 2 Tap OK to verify the password or tap X to cancel ...

Страница 152: ...mmands and metatags see Locked Web Browser Options LockedWeb Tab on page 144 Error Page Redirection Use the Error redirection option to provide customized recovery from common errors When an error occurs the browser can redirect access to a specified error page with instructions on how to recover from the problem NOTE Locked Web Browser is disabled by default To enable use the Advanced Settings ta...

Страница 153: ...cons Options Status Tab on page 149 The status icons can be configured on the Status tab of DDU Trap Keys When selected all key presses will be trapped by the Locked Web Browser to prevent the user from accessing unsafe parts of the sys tem For example pressing Ctrl O to open a file will not work safe key presses e g Alpha numeric will still get processed by the Locked Web Browser as normal For ex...

Страница 154: ...rowser Home Page Sets the Internet Explorer home page regardless of the enable state of the Locked Web Browser Advanced Allows to enable the Locked Web Browser and to configure advanced settings Advanced Locked Web Browser Options General Enable Locked Web Browser Enables the Locked Web Browser when Internet Explorer is launched Disable Cache Prevents the browser from loading the local intranet pa...

Страница 155: ...ption is selected on the LockedWeb tab in DDU Context Menu Enable Context Menu Enables the context menu accessed by a touch screen tap in the Locked Web Browser Refresh Adds a Refresh item to the Locked Web Browser context menu Stop Adds a Stop item to the Locked Web Browser context menu Selecting during navigation stops the downloading of a page Current URL Adds a Current URL item to the Locked W...

Страница 156: ...Adds a Minimize item to the Locked Web Browser context menu Selecting the item minimizes the Locked Web Browser and allows access to other programs Show SIP Adds a Show SIP item to the Locked Web Browser context menu Selecting the item toggles the show state of the SIP Exit Adds an Exit item to the Locked Web Browser context menu Selecting the item exits the Locked Web Browser with an optional pas...

Страница 157: ...s the Status Icons option You can configure the view of some status icons that are used in LockedWeb and in Application Selector to display the status of Wi Fi radio and battery Status Icons Options Icon size Sets the status icons size Icon locations Selects the preferred location for each status icon ...

Страница 158: ...ent applications Windows Controls Show taskbar Select to display hide the Taskbar Taskbar enabled Select to display the taskbar This option is only available when Show taskbar is selected Start menu enabled Select to display the Start Menu This option is only available when Taskbar enabled is selected AutoSIP enabled Enables the AutoSIP Windows feature Scroll bars enabled Select to display horizon...

Страница 159: ...Datalogic Applications User s Manual 151 NOTE Changes require a device reboot ...

Страница 160: ...nable Application Selector Select to enable the application selector Show status icons Select to enable the status icons view see Status Icons Options Status Tab on page 149 The status icons can be configured on the Status tab of DDU Authorized applications List of applications that the user can access Application Selector Commands New Tap to create a new application entry Edit Tap to edit the sel...

Страница 161: ...of the application in the way it should appear on screen for the end user Executable Displays the path for the executable file you want to run Browse Tap to browse for the desired executable file You can associate an executable program with the specified button The results of this search are displayed in the Executable textbox Arguments Type any command line arguments to be used when an applicatio...

Страница 162: ...tion Selector starts up Applications will be started in the order listed in the authorized application list Delay Enter a delay duration in seconds in the combo box This option delays auto start of application s to allow drivers to load before starting applications OK Tap to add save changes X Tap to cancel Command Description ...

Страница 163: ...list of applications By default the Application Selector comes with no applications preset The administrator can customize this list as shown in AppSelector Options AppSelect Tab on page 152 Additionally the page template can be modified to display a different background Contact your Datalogic representative for more information on this feature To run an application tap its name To exit the Applic...

Страница 164: ...password is required to exit This means users can only access web applications and websites set by the administrator In full screen mode status icons may be used to display signal strength and battery status In CE mode the status bar is displayed but the user interaction is disabled NOTE Configuration is set up through the DDU control panel See Locked Web Browser Options LockedWeb Tab on page 144 ...

Страница 165: ...re versions 1 60 and greater the following command line arguments are supported E optional parameter which allows for Exit without entering a password URL optional parameter which specifies a URL to use as a home page C optional parameter which disables the ctrl keys including the one to exit Home Ctrl 7 Refresh Ctrl 8 Cancel Ctrl 9 Exit Ctrl 0 ...

Страница 166: ... page The Datalogic Locked Web Browser defines some special metatags that allow the web application to interact with the device In particular the special metatags allow it to enable disable scan engine triggers enable disable specific symbologies in the scan engine easily assign a key press to a javascript function Metatag settings of trigger enable symbology enable or DL_Key assignments persist p...

Страница 167: ...uld be a javascript function that receives one parameter the serial number An example would be function CustomerFunction SerialNumber Reboot Warm Boot Device Metatag DL_Reboot Warm boot device Content OnPageLoad Warm boot immediately upon page load Example meta http equiv DL_Reboot content OnPageLoad Exit Metatag DL_Exit Exit the Locked Web Browser Content OnPageLoad Exit immediately upon page loa...

Страница 168: ...S25 DL_Code_M25 DL_Code_CODABAR DL_Code_93 DL_Code_UPCA DL_Code_UPCE DL_Code_EAN13 DL_Code_EAN8 DL_Code_MSI DL_Code_MSR DL_Code_GS1_14 DL_Code_GS1_LIMIT DL_Code_GS1_EXP DL_Code_PDF417 DL_Code_DATAMATIX DL_Code_MAXICODE DL_Code_TRIOPTIC DL_Code_PHARMA39 DL_Code_RFID DL_Code_MICROPDF417 DL_Code_COMPOSITE DL_Code_QRCODE DL_Code_AZTEC DL_Code_POSTAL Examples meta http equiv DL_Code_39 content Disable ...

Страница 169: ... use on the page For instance when entering data in a text box a character assigned as a DL_Key would not be entered in the text box Instead the javascript action would occur Refer to the Microsoft website to find the list of all the possible Vkey codes http msdn microsoft com en us library bb431750 aspx http msdn microsoft com en us library aa243025 VS 60 aspx NOTE Because DL_Keys persist past th...

Страница 170: ... mode and start listening for scan events A scanned barcode tag result will be used as an argument to that javascript function which is then invoked If the content value is Wedge then the device will stop listening for scanned event and enter keyboard wedge mode If the content value is Disable then the device will stop listening for scanned events but not enter keyboard wedge mode Example meta htt...

Страница 171: ...at is ready to use for data entry needs Pal Communicator is a PC application that allows you to manage the data transfer between a host computer and mobile devices For further information refer to the Pal Pal Communicator User s Guide downloadable from our website see Support Through the Website on page 239 ...

Страница 172: ...h line with the specified command line arguments It will take into account any AutoStart options at the beginning of the line Upon a Cold Boot AutoStart installs all the CAB files located in the FlashDisk CAB folder If the CAB folder does not exist no CAB files will be installed AutoStart will then run the Autostart ini from the flashDisk directory executing each line with the specified command li...

Страница 173: ...interactive installers you should either install the CABs manually or review the section Interactive CAB Install on page 166 CAUTION In certain environments CAB files will be deleted after execution To prevent the CAB file from being deleted write protect the file before copying the file onto the device Option Description noui Specifies that you will not be prompted for any input during the instal...

Страница 174: ...lled with Wceload without any command line arguments specified An example of what AutoStart would execute is Windows Wceload exe cab file To force this mode of installation via AutoStart rename the CAB file to include a _ character before the cab extension of the file Example File cab should be renamed File_ cab to force AutoStart to not install the CAB in silent mode This specially named CAB file...

Страница 175: ... full path to executable command line arguments Sample windows pword exe file doc The following table breaks down the sample Autostart ini line Spaces must be placed between each component of the line in the Autostart ini NOTE A file named PreAuto ini can also be created in addition to or instead of Autostart ini PreAuto ini is executed before CAB files in the FlashDisk CAB folder are installed Au...

Страница 176: ...the name quotes are required to distinguish what the actual executable name is The following is an example of this Program Files ScannerApp exe run valid Program Files ScannerApp exe run invalid The second line is an invalid line because there is no way to distinguish the executable from the argument ...

Страница 177: ...e used as the first character of the line If the comment option is specified in the options elsewhere it is ignored Do not wait on line completion This will cause the line to execute and immediately move onto the next line Query Request user confirmation when running the executable This will halt parsing the Autostart ini until the confirmation is answered This is intended for debugging the Autost...

Страница 178: ...waiting on the current line to complete execution Query Option The query option is intended for use when debugging the autostart ini When a line with this option is executed the fol lowing dialog box will appear with the specified executable and command line arguments The populated fields shown in the AutoStart Execute Query are described the next table Field Description Line Number The line numbe...

Страница 179: ...scribes the results of each choice NOTE The fields may be broken up into multiple lines as shown in the example due to limited space in the dialog box Button Action Yes The current line will execute No The current line will not execute AutoStart will continue parsing the Autostart ini Cancel The current line will not execute and AutoStart will discontinue parsing the Autostart ini ...

Страница 180: ...will execute Program with the argument Files App exe Program Files App exe run invalid This will execute Program with the argument Files App exe run Program Files App exe run This will execute the program Program Files App exe with the argument run Windows Pword exe This will confirm the execution of Windows Pword exe If the execution is confirmed AutoStart will immediately process the next line P...

Страница 181: ... newer for Windows 7 32 bit computers http www microsoft com download en details aspx id 14 Windows Mobile Device Center 6 1 or newer for Windows 7 64 bit computers http www microsoft com download en details aspx id 31 82 For C C C development Microsoft Visual Studio 2008 Microsoft Visual Studio 2008 Service Pack 1 http go microsoft com fwlink LinkId 122094 or https www microsoft com en us downloa...

Страница 182: ...or Windows Embedded Compact 7 https support microsoft com en us kb 2468183 Windows Mobile 6 Professional Development Kits Refresh is required for all Windows Mobile or Windows Embedded Handheld 6 5 devices using C C C languages Go to this link to download the file http www microsoft com en us download details aspx id 6135 Windows Mobile 6 Professional Development Kits Refresh is also required for ...

Страница 183: ... on configuring the scanner settings Imager 1D Data Capture The imager uses digital camera technology to take a digital picture of a barcode the image is stored in memory and software decoding algorithms are executed to extract the data from the image To scan a barcode symbol 1 From the Decoding Properties window tap the barcode icon to open the Decoded Data window or ...

Страница 184: ... Microsoft WordPad icon 2 Point the scan window at the barcode from a distance within the reading range 3 Press the scan key or the pistol trigger The green lighted band emitted by the imager must completely cross the barcode as shown in the figure on the next page ...

Страница 185: ...n spot onto the barcode image The barcode type and content data display on the screen The field of view changes its size as you move the reader closer or farther away from the barcode Scan symbols with smaller bars or elements mil size closer to the unit and those with larger bars or elements mil size farther from the unit Hold the Skorpio X4 between two and nine inches depending on symbol density...

Страница 186: ...oftware decoding algorithms are executed to extract the data from the image The omni directional scanning does not require that the operator orient the barcode to align with the scan pattern To scan a barcode symbol 1 From the Decoding Properties window tap the barcode icon to open the Decoded Data window or From the WEC7 desktop double tap the Microsoft WordPad icon ...

Страница 187: ...as The aiming pattern is used to position the barcode or object within the field of view 4 Center the symbol in any orientation within the aiming pattern Ensure the entire symbol is within the rectangular area formed by the brackets in the aiming pattern then either wait for the timeout or release the scan key to capture the image A red beam illuminates the symbol which is captured and decoded Lin...

Страница 188: ...you move the reader closer or farther away from the barcode The aiming pattern is smaller when the imager is closer to the barcode and larger when it is farther from the barcode Scan symbols with smaller bars or elements mil size closer to the unit and those with larger bars or elements mil size farther from the unit Hold the Skorpio X4 between two and nine inches depending on symbol density from ...

Страница 189: ... Windows Mobile Device Center can be downloaded from Microsoft website www microsoft com It is only compatible with Windows Vista and Windows 7 if you run Windows XP or earlier you have to download Microsoft ActiveSync You can establish a connection to your Skorpio X4 through the following interfaces USB either directly or through the Single Dock RS232 either directly or through the Single Dock Bl...

Страница 190: ...hen you finish the setup wizard Windows Mobile Device Center synchronizes the mobile computer automatically Microsoft Office Outlook emails and other information will appear on your device after synchronization NOTE The Skorpio X4 running WEC7 does not come equipped with Microsoft Office Outlook or any other application that allows users to view contact calendar e mail or task data Users can view ...

Страница 191: ...ion You can use any standard USB charge communication cable to directly connect the Skorpio X4 to a host computer and transfer data through the USB interface NOTE Connection through the cable complies to USB 2 0 standard Host Computer Skorpio X4 Standard USB cable ...

Страница 192: ...an use the Datalogic HandyLink cable 94A051970 to directly connect the Skorpio X4 to a host computer to transfer data through the USB interface NOTE The HandyLink cable complies to USB 2 0 standard Host Computer Skorpio X4 94A051970 HandyLink USB Client Cable ...

Страница 193: ...the Skorpio X4 mobile computer into the dock NOTE Connection through the dock complies to USB 2 0 standard NOTE The actual data transfer speed can be appreciably lower than the maximum theoretical speed CAUTION Don t insert the wall charger into the micro USB port when the Skorpio X4 is inserted into the dock Host Computer 94A051968 Micro USB Client Cable Skorpio X4 Single Slot Dock Power Supply ...

Страница 194: ...nk Micro USB host cable together with a standard USB cable if needed For all these devices maximum current draw must be less than 100mA A standard USB cable is needed only if the USB hard driver or flash memory device does not include its own cable with a A plug on it Keyboard with USB interface Standard USB cable Skorpio X4 USB hard drive external memory source 94A051971 HandyLink Micro USB Host ...

Страница 195: ...ory device does not include its own cable with a A plug on it NOTE Skorpio X4 works with most of the mentioned USB peripherals Datalogic cannot guarantee the interoperability of Skorpio X4 with all devices on the market NOTE Connection complies to USB 2 0 standard NOTE The actual data transfer speed can be appreciably lower than the maximum theoretical speed USB hard drive external memory source 9...

Страница 196: ...The Single Slot Dock can be connected to the Host by means of a standard null modem cable such as Datalogic 94A051020 CAB 427 for 9 pin connections Once the host computer has been turned on insert the Skorpio X4 mobile computer into the cradle Host Computer Skorpio X4 94A051972 HandyLink Micro RS232 Client Cable Host Computer Skorpio X4 Single Slot Dock 94A051020 CAB 427 RS232 Null Modem Cable Pow...

Страница 197: ...2 11 a b g n radio models can communicate with the host using the on board Wi Fi radio and an Access Point connected to a network For more information on this utility refer to WCU Wireless Configuration Utility on page 61 Skorpio X4 Access Point Host Skorpio X4 ...

Страница 198: ...end battery life the Bluetooth module is off by default To enable the Bluetooth open the Bluetooth Manager Window see Bluetooth Manager Device Setup on page 73 NOTE Suspending the terminal powers off the Bluetooth radio and drops the Bluetooth connection When the terminal resumes it takes approximately 10 seconds for the Bluetooth radio driver to re initialize the radio Skorpio X4 Bluetooth Printe...

Страница 199: ...Connections User s Manual 191 NOTE Area coverage and Bluetooth radio performance may vary due to environmental conditions or interference caused by other devices microwave ovens radio transmitters etc ...

Страница 200: ...w the same recommendations provided by Health Industry Manufacturers Associations for mobile phones Persons with pacemakers Should ALWAYS keep this device more than twenty five 25 cm from their pacemaker and or any other medical device Should not carry this device in a breast pocket Should keep the device at the opposite side of the pacemaker and or any other medical device Should turn this device...

Страница 201: ...ing your vehicle You should also consult the manufacturer of any equipment that has been added to your vehicle An air bag inflates with great force DO NOT place objects including either installed or portable wireless equipment in the area over the air bag or in the air bag deployment area If a vehicle s wireless equipment is improperly installed and the air bag inflates serious injury could result...

Страница 202: ...le liquids explosive gases or materials with the device or its parts or accessories Areas with a potentially explosive atmosphere are often but not always clearly marked or shown Sparks in such areas could cause an explosion or fire resulting in injury or even death ...

Страница 203: ...ery 422 g 14 9 oz Pistol Grip with standard battery 482 g 17 0 oz Pistol Grip with hi cap battery 516 g 18 2 oz Display TFT Transflective LCD with 240 x 320 pixel resolution LED backlight and integrated touch screen 3 2 inch diagonal Keyboard 50 key full alphanumeric 38 key functional or 28 key numeric keyboard with backlight Environmental Drop Resistance Withstands drops from 1 8 m 6 0 ft onto co...

Страница 204: ...p models Wireless Communications Local Area Network WLAN TI Wi Link 8 IEEE 802 11a b g n Frequency Range Country dependent typically 2 4 and 5 GHz Cisco Compatible CCX v4 Security Personal Area Network WPAN Bluetooth v4 with BLE Android models Bluetooth v2 1 EDR WEC7 models Interfaces Interfaces Main connector with USB 2 0 High Speed Host 480 Mbps and Client RS 232 up to 115 2 Kbps MicroUSB port f...

Страница 205: ...ed for firmware and reserved data Software Applications Pal Application Library pre licensed WEC7 only Configuration Maintenance Wavelink Avalanche pre licensed WEC7 only 42 Gears SureLock pre licensed for device lockdown Android only SOTI MobiControl Datalogic xPlatform Utility DXU pre licensed Datalogic Desktop Utility DDU pre licensed for device lockdown WEC7 only Development WEC7 Datalogic Win...

Страница 206: ...Codes UPC EAN JAN Composites GS1 DataBar Composites and GS1 128 Composite Composites supported on WEC7 only Reading Performance 2D Imager Standard Range Megapixel sensor for extended range White LED Illumination Optical Resolution 1D codes 3 mils 2D codes 6 6 mils Depth of Field typical 4 5 to 74 cm 1 7 to 29 1 in 13 mil EAN depending on bar code density and type 1D Imager 2500 pixel sensor Sharp ...

Страница 207: ...ory approvals for its intended use Enviromental Compliance Complies to EU RoHS Laser Classifications VLD Class 2 IEC EN60825 1 Compliant with 21 CFR 1040 10 except for deviations pursuant to laser notice No 50 dated June 24 2007 LED Classification Exempt Risk Group IEC EN62471 Warranty Warranty 1 Year Factory Warranty ...

Страница 208: ...stances Skorpio X4 Imager 1D Linear CCD Resolution mils Barcode Type Far Typical Working Ranges 3 mils Code 39 6 30 in 16 cm 5 mils Code 39 11 81 in 30 cm 10 mils Code 128 19 69 in 50 cm 13 mils EAN 25 20 in 64 cm 20 mils Code 39 47 24 in 120 cm ...

Страница 209: ...mager 2D Resolution mils Barcode Type Far Typical Working Ranges 3 mils Code 39 7 48 in 19 cm 5 mils Code 39 12 99 in 33 cm 10 mils Datamatrix 9 84 in 25 cm 13 mils EAN13 25 59 in 65 cm 15 mils Datamatrix 13 78 in 35 cm 20 mils Code 39 39 37 in 100 cm ...

Страница 210: ...Technical Features 202 Skorpio X4 NOTES ...

Страница 211: ...User s Manual 203 Test Codes High Density Codes 0 25 mm 10 mils Code 39 17162 Interleaved 2 5 0123456784 Code 128 test ...

Страница 212: ...Test Codes 204 Skorpio X4 High Density Codes continued 0 25 mm 10 mils 80 EAN 13 80 EAN 8 ...

Страница 213: ...Test Codes User s Manual 205 Medium Density Codes 0 38 mm 15 mils Code 39 17162 Interleaved 2 5 0123456784 Code 128 test ...

Страница 214: ...Test Codes 206 Skorpio X4 Medium Density Codes continued 0 38 mm 15 mils 100 EAN 13 100 EAN 8 ...

Страница 215: ...Test Codes User s Manual 207 Low Density Codes 0 50 mm 20 mils Code 39 17162 Interleaved 2 5 0123456784 Code 128 test ...

Страница 216: ...Test Codes 208 Skorpio X4 Low Density Codes continued 0 50 mm 20 mils 120 EAN 13 120 EAN 8 ...

Страница 217: ...Test Codes User s Manual 209 2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example ...

Страница 218: ...Test Codes 210 Skorpio X4 NOTES ...

Страница 219: ...ee dry cloth or lens tissue to clean the product contacts and plastics An antistatic cloth is preferable but you can also use a cotton cloth Avoid wool synthetic cloths or other materials that can cause electrostatic discharges If the contacts are very dirty clean them with a soft cloth moistened with a diluted non aggressive cleaning solution or a diluted isopropyl alcohol solution 20 maximum A c...

Страница 220: ... solution 20 maximum 3 Gently rub the cloth back and forth ONLY along the contacts following the directions indicated by the red arrows Use care not to leave any cloth residue 4 Use a dry cloth to remove any dirt near the contacts area and to clean the plastic parts If the plastic parts of the equipment are very dirty slightly dampen the cloth with only water 5 Repeat steps 2 3 and 4 using a clean...

Страница 221: ...ive cleaning solution or diluted isopropyl alcohol solution 20 maximum 3 Gently rub the cloth back and forth ONLY along the contacts following the directions indicated by the red arrows Use care not to leave any cloth residue 4 Use a dry cloth to remove any dirt near the contacts area and to clean the plastic parts If the plastic parts of the equipment are very dirty slightly dampen the cloth with...

Страница 222: ...ghts Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures CAUTION In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below Consult with your local Health Safety Manager to ensure that you are adhering to your company s s...

Страница 223: ...ring will invalidate the warranty When replacing the battery pack or at the end of the operative life of the Skorpio X4 disposal must be performed in compliance with the laws in force in your jurisdiction Do not submerge the Skorpio X4 in liquid products For further information or support refer to this manual and to the Datalogic web site www datalogic com NOTE Read this manual carefully before pe...

Страница 224: ...urce which supplies power directly to the unit via the micro USB connector of the cable The device could be also used with Certified Accessories Dock Cradle The Dock Cradle accessories are intended to be supplied by a UL Listed CSA Certified Power Unit LPS SELV which supplies power via the power connector of the cable Any changes or modifications to equipment not expressly approved by Datalogic co...

Страница 225: ...uman eye and is emitted from the window indicated in the figure below LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX OUTPUT RADIATION 1 mW COMPLIANT WITH EN 60825 1 2007 and EN 60825 1 2014 NOTE The artwork below may be only a draft Please refer to the label attached to the product for information about certification marks Laser Warning Label Printed Data Label Marks Label Scan Windo...

Страница 226: ...FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 MASSIMA POTENZA MEDIA DI USCITA 1 mW LUNGHEZZA D ONDA EMESSA 630 680 nm CONFORME A EN 60825 1 2007 E EN 60825 1 2014 LASERSTRAHLUNG NICHT IN DER STRAHL BLINKEN PRODUKT DER LASERKLASSE 2 MAXIMALE DURCHSCHNITTLICHE AUSGANGLEISTUNG 1 mW WELLENLÄNGE 630 680 nm ENTSPR EN 60825 1 2007 UND EN 60825 1 2014 RAYON LASER EVITER DE REGARDER LE RAYON APPAREILLASE...

Страница 227: ...hough staring directly at the laser beam momentarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid shining laser light into any person s eye even through reflective surfaces such as mirrors etc WARNING Do not attempt to open or otherwise service any components in the optics cavity Opening or servicing any part of th...

Страница 228: ...o manutenzione WARNING Use of optical systems with the scanner will increase eye hazard Optical instruments include binoculars microscopes eye glasses and magnifying glasses ATTENZIONE Non tentare di accedere allo scomparto contenete i componenti ottici o di farne la manutenzione L apertura dello scomparto o la manutenzione di qualsiasi parte ottica da parte di personale non autorizzato potrebbe v...

Страница 229: ...e gli specchi DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein die von internationalen Behörden auferlegt wurden und sie beziehen sich auf den korrekten Gebrauch vom Terminal NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825 1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit Es ist nicht notwendig das Gerät wegen Be...

Страница 230: ...ucht werden die Komponenten im Optikhohlraum zu öffnen oder auf irgendwelche andere Weise zu warten Das Öffnen bzw Warten der Komponenten im Optikhohlraum durch unbefugtes Personal verstößt gegen die Laser Sicherheitsbestimmungen Das Optiksystem darf nur werkseitig repariert werden ACHTUNG Jegliche Änderungen am Gerät sowie Vorgehensweisen die nicht in dieser Betriebsanleitung beschreiben werden k...

Страница 231: ...constaté à la suite d une exposition au rayon laser Eviter de regarder fixement le rayon comme toute autre source lumineuse intense telle que le soleil Eviter aussi de diriger le rayon vers les yeux d un observateur même à travers des surfaces réfléchissantes miroirs par exemple ATTENTION Ne pas essayer d ouvrir ou de réparer les composants de la cavité optique L ouverture de la cavité optique ou ...

Страница 232: ... L utilisation d instruments optiques avec le scanneur augmente le danger pour les yeux Les instruments optiques comprennent les jumelles les microscopes les lunettes et les verres grossissants ATENCIÓN No intente abrir o de ninguna manera dar servicio a ninguno de los componentes del receptáculo óptico Abrir o dar servicio a las piezas del receptáculo óptico por parte del personal no autorizado p...

Страница 233: ...sified as EXEMPT RISK GROUP according to IEC62471 Marking and European Economic Area EEA In radio systems configured with mobile computers and access points the frequencies to be used must be allowed by the spectrum authorities of the specific country in which the installation takes place Be absolutely sure that the system frequencies are correctly set to be compliant with the spectrum requirement...

Страница 234: ... i direktiv 2014 53 EU 2011 65 EU de Deutsch German Hiermit erklärt Datalogic S r l dass sich das Gerät Skorpio X4 in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 2014 53 EU 2011 65 EU befindet et Eesti Estonian Käesolevaga kinnitab Datalogic S r l seadme Skorpio X4 vastavust direktiivi 2014 53 EU 2011 65 EU põhinõuetele ja nimetatud...

Страница 235: ...r l dat het toestel Skorpio X4 in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 2014 53 EU 2011 65 EU mt Malti Maltese Hawnhekk Datalogic S r l jiddikjara li dan Skorpio X4 jikkonforma mal ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid Dirrettiva 2014 53 EU 2011 65 EU hu Magyar Hungarian Alulírott Datalogic S r l nyilatkozom hogy a...

Страница 236: ...ladné požiadavky a všetky príslušné ustanovenia Smernice 2014 53 EU 2011 65 EU fi Suomi Finnish Datalogic S r l vakuuttaa täten että Skorpio X4 tyyppinen laite on direktiivin 2014 53 EU 2011 65 EU oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen sv Svenska Swedish Härmed intygar Datalogic S r l att denna Skorpio X4 står I överensstämmelse med de väsentliga egenskapskra...

Страница 237: ... indoor use when operated in the 5 15 to 5 25 GHz frequency range Changes or modifications made to this equipment not expressly approved by Datalogic S r l may void the FCC authorization to operate this equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable p...

Страница 238: ...rmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the rece...

Страница 239: ...ge et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement CAUTION i the device for operation in the band 5150 5250 MHz is only for indoor use to reduce the potential for harmful interference to co channel mobile satellite systems ii high power radars are allocated as primary users i e priority us...

Страница 240: ...es utilisateurs de radars de haute puissance sont désignés utilisateurs principaux c à d qu ils ont la priorité pour les bandes 5 250 5 350 MHz et 5 650 5 850 MHz et que ces radars pourraient causer du brouillage et ou des dommages aux dispositifs LAN EL ...

Страница 241: ... section Europe This device is compliant with SAR limits for general population uncontrolled exposure specified in Council Recommendation 1999 519 EC Annex II US and Canada For body worn operation this device has been tested and meets the FCC ISED RF exposure guidelines for use with an accessory that contains no metal and the positions the handset a minimum of 0 cm from the body Use of other enhan...

Страница 242: ...ified below Europe Radio Technology Frequency Bands Radio Frequency TransmittedPower WLAN IEEE 802 11b g n SISO 20MHz channels bandwidth HT 20 MIMO support 20MHz channels bandwidth HT 20 2 4GHz Frequency Bands 2 412 2 472 MHz 19 45 dBm WLAN IEEE 802 11a n SISO 20MHz and 40Mhz channels band width HT 20 and HT 40 5GHz Frequency Bands 5 180 5 240 MHz 5 260 5 320 MHz 5 500 5 700 MHz 19 27 dBm Bluetoot...

Страница 243: ...g n SISO 20MHz channels bandwidth HT 20 MIMO support 20MHz channels bandwidth HT 20 2 4GHz Frequency Bands 2 412 2 462 MHz WLAN IEEE 802 11a n SISO 20MHz and 40Mhz channels bandwidth HT 20 and HT 40 5GHz Frequency Bands 5 180 5 240 MHz 5 260 5 320 MHz 5 500 5 700 MHz 5 735 5 825 MHz Bluetooth V4 0 EDR LE 2402 2480Mhz ...

Страница 244: ...olo del bidone barrato deve essere smaltita alla fine della sua vita utile separatamente dai rifiuti urbani Per maggiori dettagli sulle modalità di smaltimento contattare il Fornitore dal quale è stata acquistata l apparecchiatura o consultare la sezione dedicata sul sito http www datalogic com Information aux utilisateurs Au terme de sa vie utile le produit qui porte le symbole d un caisson à ord...

Страница 245: ... por favor póngase en contacto con el proveedor donde lo compró o consultar la sección dedicada en el Web site http www datalogic com Benutzerinformation bezüglich Am Ende des Gerätelebenszyklus darf das Produkt nicht über den städtischen Hausmüll entsorgt werden Eine entsprechende Mülltrennung ist erforderlich Weitere Informationen zu dieser Richtlinie erhalten sie von ihrem Lieferanten über den ...

Страница 246: ...Safety and Regulatory Information 238 Skorpio X4 NOTES ...

Страница 247: ...electing your product model from the dropdown list in the Search by Product field for specific Data Sheets Manuals Software Utilities and Drawings Repair Program for On Line Return Material Authorizations RMAs plus Repair Center contact information Customer Service containing details about Maintenance Agreements Technical Support through email or phone Warranty Terms and Conditions The warranty pe...

Страница 248: ...Reference Documentation 240 Skorpio X4 NOTES ...

Страница 249: ...of app application it refers to simple single function programs that often ship with a larger product Programs such as Windows Calculator File Manager Control Panel and Notepad are examples of applets ASCII American Standard Code for Information Interchange A 7 bit plus parity code representing 128 letters numerals punctuation marks and control characters It is a standard data transmission code in...

Страница 250: ...with Enhanced Data Rate EDR Boot The process a computer goes through when it starts During boot the computer can run self diagnostic tests and configure hardware and software Byte On an addressable boundary eight adjacent binary digits 0 and 1 combined in a pattern to represent a specific character or numeric value Bits are numbered from the right 0 through 7 with bit 0 the low order bit One byte ...

Страница 251: ...ers per inch Depth of Field DOF The portion of a scene that appears acceptably sharp in the image Although a lens can precisely focus at only one distance the decrease in sharpness is gradual on each side of the focused distance so that within the DOF the unsharpness is imperceptible under normal viewing conditions Dock A dock is used for charging the terminal battery and for communicating with a ...

Страница 252: ...e it is actually a type of flash memory Flash Memory Non volatile memory for storing application and configuration files Host A computer that serves other mobile computers in a network providing services such as network control database access special programs supervisory programs or programming languages IEC International Electrotechnical Commission This international agency regulates laser safet...

Страница 253: ...escent light bulb but more than a Liquid Crystal Display LCD Liquid Crystal Display LCD A display that uses liquid crystal sealed between two glass plates The crystals are excited by precise electrical charges causing them to reflect light outside according to their bias They use little electricity and react relatively quickly They require external light to reflect their information to the user MI...

Страница 254: ...ve different values assigned to it RAM Random Access memory Data in RAM can be accessed in random order and quickly written and read Resolution The narrowest element dimension which is distinguished by a particular reading device or printed with a particular device or method RF Radio Frequency Scanner An electronic device used to scan barcode symbols and produce a digitized pattern that correspond...

Страница 255: ... toggle key activates the state The state remains active until the toggle key is pressed again USB Universal Serial Bus Type of serial bus that allows peripheral devices disks modems printers digitizers data gloves etc to be easily connected to a computer A plug and play interface it allows a device to be added without an adapter card and without rebooting the computer the latter is known as hot p...

Страница 256: ... users the mobility to move around within a local coverage area and still be connected to the network WPAN A Wireless Personal Area Network is a personal area network a network for interconnecting devices centered around an individual person s workspace in which the connections are wireless Typically a wireless personal area network uses some technology that permits communication within about 10 m...

Страница 257: ...Glossary User s Manual 249 NOTES ...

Страница 258: ...ights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Datalogic S r l Via S Vitalino 13 Calderara di Reno 40012 BO Italy Tel 39 051 3147011 Fax 39 051 3147205 822002291 Rev A April 2018 ...

Отзывы: