Figure 2 - Inserting the scanner in the Heated Holder
OPERATION
1. If the Heated Holder is connected to the ignition switch, turning the ignition switch on or off will control the heated holder. An LED
illuminated from the inside of the holder indicates the power is on.
2. Place the scanner into the holder (see Figure 2). Push the scanner through the front brushes as far as it will go. The brushes should
return to their original position.
WARNING: Do not put your fingers or hands inside the unit while it is on. Surfaces inside the unit are hot and may cause
burns. Do not use the Heated Holder as a handle; it is not intended to support human weight.
Heated
Holder
Scanner
Front
Brushes
European Declaration of Conformity
Hereby, Datalogic USA, Inc. declares that the full text of the Euro
-
pean Declaration of Conformity is available at: www.datalogic.com.
Select the Support & Service > Downloads > Product Certifications
link where you can search for your specific product certification.
UKCA Declaration of Conformity
Hereby, Datalogic USA, Inc. declares that the full text of the UKCA
Declaration of Conformity is available at: www.datalogic.com.
Select the Support &Service >Downloads > Product Certifications
link where you can search for your specific product certification.
CHINA ROHS TABLE
SPECIFICATIONS
Physical
Dimensions
•
7.7 in. (19.6 cm) L
•
4.8 in. (12.2 cm) W
•
3.9 in. (9.9 cm) H
Environmental
Temperature
•
Internal operating: Operating Solid State Control at 95º-
105ºF (35º-40ºC)
•
Ambient operating: 22º to 104ºF (-30º to 40ºC)
•
Storage: -40º to 158ºF (-40º to 70ºC)
Humidity (Ambient)
: 5% to 95% (non-conducting)
Vibration
: MIL-STD-810E. Method 514.4, Procedure 1
Approvals
CE, TUV
Electrical
Power Cable
•
10 ft. (3.05 m) L (unterminated)
•
18/2 Conductor cable
•
Red wire: + positive lead
•
Black wire: - negative lead
Model Number
Input Voltage
Power Output (Nom.)
11-0139
24 VDC
75W
11-0138
36 VDC
75W
11-0140
48 VDC
75W