Manual Datafox EVO 3.5 Universal
Seite 40
Datum: 26.11.2018 04.03.11.XX
Identifier
Data type
Length
Description
ID
Number
(int)
4
ID of the room. All other tables refer to this data line via this number, if neces-
sary.
RefGroup
Number
(int)
4
Reference to the identification table. Labels the access authorized group. All
cards of this group have access to this room.
RefTime
Number
(int)
4
The time model in which authorized persons get access. (0 = not used)
RefTimeNoPin
Number
(int)
4
The time model for which entering an additional PIN is not necessary (at peak
times etc.).
Table Location (defines which card groups get access to which room at which time)
Name
Data type
Length
Description
ID
Number
(int)
4
ID of the time model. All other tables refer to this data line via this number, if
necessary.
Weekdays
Number
(int)
7
Indicates the weekdays on which the following period of time should be applied
(form: 7 digits at most 1-7 e.g. 134567 = Monday, Wednesday till Sunday)
TimeStart
Text
(Time)
5
The start point for the period of time. (form: 24h HH:MM)
TimeEnd
Text
(Time)
5
The end point for the period of time.
Table Time (grouping of single time zones (weekday from to) as a time model number)
Name
Data type
Length
Description
RefReader
Number
(int)
4
Module (door module or master) where the digital input is.
PortIn
Number
(int)
1
Number of the digital input on the module.
RefAction
Number
(int)
4
Reference to the action that should be carried out (e.g. switch relay).
RefTime
Number
(int)
4
The time model which indicates when the digital input is checked. (0 = not
used).
Table Event (assigning an action to a signal at the digital input)
Name
Data type
Length
Description
ID
Number
(int)
4
Action number, it can occur several times due to several actions that have to be
worked through.
RefReader
Number
(int)
4
Module (door module or master) on which an output(relay) is switched.
PortOut
Number
(int)
1
Indicates the number of the output on the module.
Elapse
Number
(int)
3
The duration of the switching of the relay (0 = permanently). Unit 200 ms
RefTime
Number
(int)
4
The time model indicates when the output may be switched. (0 = not used)
Table Action (list of all workable actions in the access control system; an action group, i.e. all ac-
tions with the same action number, can switch several relays)