background image

VS-1212-F and VS-1224-F Data Access Switches

2

© 2012 Datacom Systems Inc

Table of Contents

Section 1 Terms of Use

3

................................................................................................................................... 3

1

Copyright

................................................................................................................................... 3

2

License Agreement

................................................................................................................................... 3

3

Proprietary Notice

.......................................................................................................................................................... 3

Tradem ark Attribution 

................................................................................................................................... 4

4

Certifications and Marks

................................................................................................................................... 4

5

Safety Notices and Warnings

Section 2 Overview

5

................................................................................................................................... 6

1

What Shipped?

................................................................................................................................... 6

2

Specifications

................................................................................................................................... 6

3

Supported SFP Transceivers

................................................................................................................................... 7

4

Front — Any-to-Any Ports

................................................................................................................................... 7

5

Front — Power and Status Indicators

................................................................................................................................... 8

6

Front — Display and Buttons

................................................................................................................................... 8

7

Rear — Power Module-

................................................................................................................................... 9

8

Rear — Management Module

Section 3 Network IP Address Configuration

9

Section 4 Stand-Alone Installation

11

................................................................................................................................... 11

1

Power Connection

................................................................................................................................... 12

2

Port Connection

Section 5 Management Connection

12

................................................................................................................................... 13

1

Web Browser

................................................................................................................................... 14

2

TELNET or SSH

Section 6 Customer Service

16

................................................................................................................................... 16

1

Warranty

................................................................................................................................... 16

2

Limits of Liability

Содержание VS-1212-F

Страница 1: ... 2012 Datacom Systems Inc Data Access Switches August 2012 541 0136 Q A 00 QUICKinstall VS 1212 F 10 100 1000 Mb and 10 Gb VS 1224 F 10 100 1000 Mb and 10 Gb ...

Страница 2: ... 5 6 1 What Shipped 6 2 Specifications 6 3 Supported SFP Transceivers 7 4 Front Any to Any Ports 7 5 Front Power and Status Indicators 8 6 Front Display and Buttons 8 7 Rear Power Module 9 8 Rear Management Module Section 3 Network IP Address Configuration 9 Section 4 Stand Alone Installation 11 11 1 Power Connection 12 2 Port Connection Section 5 Management Connection 12 13 1 Web Browser 14 2 TEL...

Страница 3: ...or implied are granted with respect to the technology described and Datacom Systems Inc retains all rights with respect to the technology described herein If applicable you may return the product to the place of purchase for a full refund 1 3 Proprietary Notice This document contains proprietary information about the VS 1212 F Data Access Switch and VS 1224 F Data Access Switch and is not to be di...

Страница 4: ...N 61000 4 6 Conducted Susceptibility This equipment completed the Product Safety Review and meets the Low Voltage Directive 98 68 EEC requirements to the standards of EN 60950 Safety of Information Technology Equipment The RoHS compliant logo indicates that this electronic product does not exceed the limit requirements of toxic hazardous substances or elements as set forth in Directive 2002 95 EC ...

Страница 5: ...arthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips 2 Overview This QUICKinstall for the VS 1212 F Data Access Switch and VS 1224 F Data Access Switch is intended to get you up and running as fast as possible using the features of your Data Acc...

Страница 6: ...0 60Hz 4 0 2 0 A Dimensions H x W x D 1 72 x 19 00 x 20 50 inch 4 37 x 48 26 x 52 07 cm Weight 18 15 lbs 8 23 kg Operating Temperature 32º to 104 F 0º to 40 C Storage Temperature 22º to 149 F 30º to 65 C Humidity Less than 95 C non condensing Warranty One 1 year see 5 2 Warranty section for details 2 3 Supported SFP Transceivers Datacom Systems supports the following small form factor pluggable SF...

Страница 7: ...iver SFP Finisar FTL1318P2BTL 1310nm SM fiber transceiver SFP Finisar FTL1318P3BTL 1310nm SM fiber transceiver SFP Stratos SPLC 20 F 1 D 1G 850nm MM fiber transceiver SFP Stratos SPLC 20 42M BH R6 1G 1310nm SM fiber transceiver SFP 2 4 Front Any to Any Ports The Any to Any PORTS are SFP sockets used for connection to devices and network segments The LINK STATUS KEY is the LED status guide for each...

Страница 8: ...up cycle and turns green upon a successful boot sequence indicating the Data Access Switch is operational NOTE STATUS LED indicator indicates the device is ready several seconds before it is ready to respond to Command Line Interface CLI commands 2 6 Front Display and Buttons The display shows Port status The Selectable Buttons are for future use VS 1212 F 2 7 Rear Power Module Two AC input power ...

Страница 9: ...s rear label 3 Network IP Address Configuration All VS 1212 F and VS 1224 F series units are shipped with a factory default configuration as follows IP Address 192 168 1 1 Subnet Mask 255 255 0 0 Gateway 192 168 1 0 User name Administrator password admin IMPORTANT If you expect to remotely connect to the VS 1212 F and VS 1224 F series you must change the IP Address Subnet Mask and Gateway to match...

Страница 10: ... Command shell prompt then type and press Enter to see a list of available commands Step 5 Set the IP address by typing SET IP xxx xxx xxx xxx where xxx xxx xxx xxx corresponds to a valid IP address for your network Press the Enter key to continue Step 6 Set the default gateway if needed by typing SET GATEWAY xxx xxx xxx xxx where xxx xxx xxx xxx corresponds to your network s default gateway Press...

Страница 11: ...red indicates a defective power source and immediate investigation as to the cause is required to insure redundant power integrity Step 1 Using the supplied AC Line Cords plug the VS 1212 F Data Access Switch and VS 1224 F Data Access Switch into different circuit external power sources Although only one power supply is required to power the VS 1212 F and VS 1224 F use of a second independent powe...

Страница 12: ...g PORT you want to connect from the VS 1212 F Data Access Switch or VS 1224 F Data Access Switch 5 Management Connection Once installation of the VS 1212 F Data Access Switch and VS 1224 F Data Access Switch has been completed in your chosen network location This section will focus on the MANAGEMENT PORT 10 100 1000 Mbs Full Duplex connection of the typical VS 1212 F Data Access Switch and VS 1224...

Страница 13: ...I through the Web Browser with the following address https ip_address Use the IP address set in the previous SERIAL Port DB9 Network IP Address Configuration section In this example https 10 1 53 86 Step 2 Users will be prompted with the login screen Users can login with the Username Administrator and default password admin The Home window is the first screen upon successful User login With an act...

Страница 14: ...ion Security related shortcomings have limited TELNET TErminaL NETwork usage although TELNET is still widely used when diagnosing problems manually talking to other services without specialized client software and administration of network elements such as integration and maintenance of core network elements Secure Shell SSH is a network protocol that uses public key cryptography that allows secur...

Страница 15: ... So if you connect to a SSH Server and it sends you a different host key from the one you were expecting you will have the chance to abandon your connection before you type any private information such as a password into it So the warning message above asks you whether you want to trust this host key or not Whether or not to trust the host key is your choice If you are connecting within a company ...

Страница 16: ...stomer Service Staff will return your call as soon as possible You may also find the assistance you need at our website http www datacomsystems com Telephone 1 315 463 9541 Internet website http www datacomsystems com 6 1 Warranty See http www datacomsystems com for warranty detailed information 6 2 Limits of Liability See http www datacomsystems com for Limits of Liability detailed information ...

Страница 17: ...Datacom Systems Inc 9 Adler Drive East Syracuse NY 13057 TEL 1 315 463 9541 FAX 1 315 463 9557 http www datacomsystems com ...

Отзывы: