Datacom Systems Tap Series Скачать руководство пользователя страница 2

Tap Series FTP-1000,2000,4000 
FASTstart Guide

For More information

© 2015 Datacom Systems, Inc    541-0149-R

DATACOM

S Y S T E M S   I N C

Customer Service 

is available from our website: www.datacomsystems.com or by c1 315 463 9541

Page 

2

Correct Wiring: 

When installing a Fiber Tap, it is important to make sure that the Tx and 

Rx fibers are connected to the respective ports on the Fiber Tap. When wired correctly, the 

traffic incoming on an Rx port will be split before being sent to two separate Tx ports (One 

copy to the other Network device, the other copy to Monitor).

Reverse Wiring: 

If the fibers are connected backwards, light will not be received on the 

monitoring port. This is because the internal coupler that splits the light is unidirectional.

To Avoid Reverse Wiring: 

Reverse wiring can be difficult to catch initially, since an 

incorrectly cabled Fiber Tap will still send light between the network ports and connectivity 

will be seen on both network endpoints. Be sure to check the for light on the monitor ports as 

well as the network ports when installing the Fiber Tap.