Chapter 5
54
The current output value then depends on the code that you write. For example, writing a
code of 0000 to the output corresponds to 0 mA; writing a code of FFFF to the output
corresponds to 20 mA.
Output Resolution
All DT9850 Series modules support an analog output resolution of 16 bits. The resolution
cannot be programmed in software.
Output Clock (Continuous Mode Only)
When in continuous output mode, described on
, you can update the analog output
channels simultaneously with continuous values using the internal clock on the module.
Using software, specify the clock source for the analog output subsystem as internal and
specify the frequency at which to update the analog output channels.
The output frequency of the module ranges between 61 Hz and 8 kHz.
The per channel output frequency is determined by dividing the frequency of the module by
the number of enabled channels. For example, to update analog output channels at the
maximum frequency of the module, divide 8 kHz by the number of enabled channels.
lists the per channel output frequency that is supported at the maximum frequency of the
module, based on the number of enabled channels.
Table 6: Per Channel Sampling Frequency at the Maximum Clock Frequency of the Module
Number of Enabled
Channels
a
a. You enable an analog output channel by specifying
it in the output channel list, described on
Maximum Sampling
Frequency
1
8000 Hz
2
4000 Hz
3
2666.666 Hz
4
2000 Hz
5
1600 Hz
6
1333.333 Hz
7
1142.857 Hz
8
1000 Hz
Содержание DT9850 Series
Страница 1: ...DT9850 Series UM 22600 M User s Manual Title Page ...
Страница 4: ......
Страница 8: ...Contents 8 ...
Страница 11: ...11 1 Overview DT9850 Series Hardware Features 12 Supported Software 14 Getting Started Procedure 15 ...
Страница 16: ...Chapter 1 16 ...
Страница 17: ...Part 1 Getting Started ...
Страница 18: ......
Страница 48: ...Chapter 4 48 ...
Страница 49: ...Part 2 Using Your Module ...
Страница 50: ......
Страница 51: ...51 5 Principles of Operation Analog Output Features 53 Digital I O Features 60 Counter Timer Features 62 ...
Страница 76: ...Chapter 6 76 ...
Страница 77: ...77 7 Troubleshooting General Checklist 78 Technical Support 80 If Your Module Needs Factory Service 81 ...
Страница 82: ...Chapter 7 82 ...
Страница 83: ...83 8 Calibration Using the Calibration Utility 84 Calibrating the Analog Output Subsystem 85 ...
Страница 86: ...Chapter 8 86 ...