Connecting Counter/Timer Signals
The BNC connection box provides five counter/timer channels that you can use to perform
the following operations:
• Event counting
• Up/down counting
• Frequency measurement
• Pulse width/period measurement
• Edge-to-edge measurement
• Continuous edge-to-edge measurement
• Pulse output (continuous, one-shot, and repetitive one-shot)
This section describes how to connect counter/timer signals. Refer to
information about using the counter/timers.
Event Counting
shows how to connect counter/timer signals to the STP connection box to perform
an event counting operation on counter/timer 0 using an external gate.
The counter counts the number of rising edges that occur on the Counter 0 Clock input when
the Counter 0 Gate signal is in the active state (as specified by software). Refer to
more information.
Figure 20: Connecting Counter/Timer Signals to the STP Connection Box for an
Event Counting Operation Using an External Gate
STP Connection Box
Signal
Source
Digital Ground
Counter 0 Clock
Digital Ground
External
Gating
Switch
TB7, 2
TB7, 4
TB7, 1
Counter 0 Gate
TB7, 5
Содержание DT9834 Series
Страница 1: ...DT9834 Series UM 19985 S User s Manual Title Page ...
Страница 4: ......
Страница 10: ...Contents 10 ...
Страница 14: ...About this Manual 14 ...
Страница 15: ...15 1 Overview DT9834 Hardware Features 16 Supported Software 19 Accessories 20 Getting Started Procedure 21 ...
Страница 22: ...Chapter 1 22 ...
Страница 23: ...Part 1 Getting Started ...
Страница 24: ......
Страница 34: ...Chapter 2 34 ...
Страница 62: ...Appendix 62 ...
Страница 73: ...Part 2 Using Your Module ...
Страница 74: ......
Страница 115: ...115 7 Troubleshooting General Checklist 116 Technical Support 118 If Your Module Needs Factory Service 119 ...
Страница 120: ...Chapter 7 120 ...
Страница 162: ...Appendix B 162 ...
Страница 175: ...175 D Ground Power and Isolation Secondary Power Connector 176 Ground Power and Isolation Connections 177 ...
Страница 186: ...Index 186 ...