Appendix D
58
lists the DT3162 values for each property of the DT-Active
Monochrome Frame Grabber control.
Table 15: DT3162 Values for the
DT-Active Monochrome Frame Grabber Control
Category
Property
DT3162 Values
General
Properties
ActiveLUT
0 or 1, in increments of 1
Timeout 0 to 65535 ms, in increments of 1 ms
Strobe
Properties
StrobeEnabled
TRUE or FALSE
StrobeStartLine
1 to 65535 lines, in increments of 1 line
StrobeStopLine
1 to 65535 lines, in increments of 1 line
StrobePolarity
ActiveHigh or ActiveLow
Expose
Properties
ExposeEnabled
TRUE or FALSE
ExposeStartLine
1 to 65535 lines, in increments of 1 line
ExposeStopLine
1 to 65535 lines, in increments of 1 line
ExposePolarity
ActiveHigh or ActiveLow
VSyncDelay
1 to 65535 lines, in increments of 1 line
Sync Input
Properties
SyncInSource
InternalSync or ExternalSync
HSyncInPolarity
ActiveHigh or ActiveLow
VSyncInPolarity
ActiveHigh or ActiveLow
Sync Output
Properties
SyncOutEnabled
TRUE or FALSE
HSyncOutPulseWidth
1 to 4095 pixels, in increments of 1 pixel
VSyncOutPulseWidth
1 to 4095 lines, in increments of 1 line
SyncOutPolarity
ActiveHigh or ActiveLow
Содержание DT3162
Страница 1: ...DT3162 UM 19131 C User s Manual ...
Страница 4: ......
Страница 39: ...29 A Specifications ...
Страница 56: ...Appendix B 46 ...
Страница 57: ...47 C RS 170 and CCIR Specifications and the DT3162 RS 170 Specification 48 CCIR Specification 52 ...
Страница 66: ...Appendix C 56 ...
Страница 67: ...57 D Values for Use with the DT Active Monochrome Frame Grabber Control ...
Страница 76: ......
Страница 80: ......