Data Link CW232 Скачать руководство пользователя страница 12

Guarantee regulations 

 

1.    Our product is shipped through an in-house inspection of our regulations, and I will repair free 

of charge when it is broken down by any chance in the guaranteed term. Please open the 

packing at once after it is accepted and examine the product. 

The guaranteed term of the Data Link product is one year from our consignment day. 

Because the product control goes with Serial No, the written guarantee is not being appended. 

Please inform me of product Serial No when it is broken down. I will limit it to the repair of the 

hardware part of this product. 

2.

 

Our company assumes the trouble indirectly to cause it by the breakdown of this product or the 

use directly with the one that it doesn't assume the responsibility. 

3.

 

In the following cases, it becomes a repair for a fee during the guaranteed term. 

⑴ 

Breakdown and damage that is caused in the transportation, fall, moving, and impact, etc. 

⑵ 

Mistake in use or remodeling, breakdown because of repair and damage. 

⑶ 

It breaks down or it damages it to fires such as a fire, the earthquake, and lightning. 

⑷ 

Breakdown and damage that originates in equipment outside our product connected with our 

product. 

4.

 

In the following cases, it is not possible to repair even for a fee. 

When the repair price exceeds a new product price by the state of the breakdown like the   

PCB substrate total loss and IC total loss, etc. 

5.

 

I will not do the business trip repair at the product breakdown. It becomes a repair of   

bringing in to our company or the shop. 

6.

 

The content of the above-mentioned guarantee is effective only in Japan. 

 

Described brand name and company name are the trademarks or registered trademarks of each company. 

 

The content of this manual is the one as of July, 2004, and the specification and the design, etc. might change 

without a previous notice for the quality improvement. Please contact a technical inquiry of this product with 

our user support section.

 

Monday – Friday 

9:00AM~12:00PM 

1:00PM

5:00PM 

TEL:

 

81-04-2924-3841 

FAX:

 

81-04-2924-3791 

Home:  http://www.data-link.co.jp 

359-1118

  埼玉県所沢市けやき台2-32-5

データリンク株式会社

Содержание CW232

Страница 1: ...m is installed the CD ROM driver is necessary Notification Memory and hard disk capacity necessary for operating the program might be different depending on the system environment used It should be tested in the above mentioned recommended environment otherwise it probably exists some instance that operation cannot be completely guaranteed according to customer s environment Various specifications...

Страница 2: ...SB socket on the PC by USB cable When the following dialog box is displayed click Next button When Please select the retrieval method dialog box is displayed please select Search for the best driver for your device and click Next button When the following dialog box is displayed please select CD ROM driver and click Next button ...

Страница 3: ...ation Windows XP After insert attached CD ROM in PC connect CW232 CW422 main body to the USB socket on the PC by USB cable When the following dialog is displayed select Install the software automatically Recommended and click Next button It will be up to Completing the Found New Hardware Wizard according to the dialog message Application program CW232 422 installation When Setup exe is double clic...

Страница 4: ...32 422 dialog box is displayed click Next button In addition the following dialog boxes are displayed Please select a setup type screen Complete C is selected usually Ready to install the program the screen When Install I was clicked the installation begins InstallShield Wizard completed the screen click Finish F and installation ends CW232 422 is started from a start menu or a desktop icon ...

Страница 5: ...splayed The count bar The number of data receptions from the equipment connected with the CH1 side is displayed in TXD The number of data receptions from the equipment connected with the CH2 side is displayed in RXD RTS high displays the frequency that RTS is changed from Busy into Ready RTS below displays the frequency that RTS is changed from Ready into Busy The change frequency of CTS DSR high ...

Страница 6: ...starting 5 It is assumed the state that can be communicated by turning on the power supply of the device at monitored both ends 6 The CW232 422 application program is set and it is assumed the state of the monitor beginning 7 The communication that wants to be actually monitored between devices at both ends begins Attention Please connect both sides in correct way Please note the signal polarity o...

Страница 7: ...enu Settings COM Settings Baud rate 50 100 110 150 200 300 600 1200 2400 4800 9600 14400 19200 28800 38400 57600 76800 115200 Under baud rate whether data can be monitored depends on the processing performance of PC According to the processing performance of PC there is a possibility of defeating Data length 7 or 8 Parity bit None Odd or Even Stop bit 1 or 2 Setup display mode Menu Settings Displa...

Страница 8: ...data does somewhat back and forth When the monitor stop button is clicked the monitor stops The monitor is stopped and the collection data is analyzed The position where the monitor data is displayed can be moved by the scroll bar After the monitor stops the collection data is analyzed If data is indicated and clicked with the mouse pointer the position of specified data is displayed The monitor d...

Страница 9: ...ox is displayed When this message is displayed analyzer application program CW232 422 is ended once Please confirm that CW232 CW422 and PC are correctly connected with an attached USB cable Analyzer application program CW232 422 is started again After starting analyzer application CW232 422 the application and CW232 CW422 cannot communicate because the USB cable comes off the following dialog box ...

Страница 10: ...upper part of the main body becomes a green light after red lights It is normal CW232 CW422 is thought of abnormity when it is not lighting such LED Please not go on using and contact our user support section This LED blinks in green while monitoring it normally When the parity error is detected during monitoring LED becomes blinking red ...

Страница 11: ...Externals chat ...

Страница 12: ...deling breakdown because of repair and damage It breaks down or it damages it to fires such as a fire the earthquake and lightning Breakdown and damage that originates in equipment outside our product connected with our product 4 In the following cases it is not possible to repair even for a fee When the repair price exceeds a new product price by the state of the breakdown like the PCB substrate ...

Отзывы: