Data Industrial 200 Series Скачать руководство пользователя страница 1

200 Series

Plastic Tee Type Flow Sensors

by Data Industrial

Owner's Manual

Introduction

Used in conjunction with any Data Industrial flow monitor or

transmitter, Data Industrial non-magnetic flow sensors provide an

accurate reading of the rate of liquid flow as well as total

accumulated flow.  A number of sensor models are offered,

which cover applications for a wide range of pipe sizes and

pressure/temperature specifications.

The flow sensors generate a frequency which is proportional to flow rate.  An internal preamplifier allows the

pulse signal to travel up to 2000 feet without further amplification.  Power to operate the sensor is provided by

the flow monitor. The impeller bearing assembly, shaft and O-rings are replaceable in the field.

Data Industrial flow sensors feature a closed, six-bladed impeller design, using a proprietary, non-magnetic

sensing technology.  The forward-swept impeller shape provides higher, more constant torque than four-bladed

impeller designs, and is less prone to fouling by water-borne debris.  The forward-curved shape, coupled with

the absence of magnetic drag, provides improved operation and repeatability, even at lower flow rates.  As the

liquid flow turns the impeller, a low impedance signal is transmitted with a frequency proportional to the flow rate.

Sensors of similar type are interchangeable, so there is no need for recalibration after servicing or

replacement.

Electronic Types

Data Industrial provides several basic sensor configurations using the same impeller element.  This allows for a

wide range of applications and pipe sizes.  Sensors are normally supplied with 20 feet of 2-conductor 20 AWG

shielded U.L. type PTLC 105°C cable. Optional sensors designated with the prefix "IR" feature two single

conductor 18 AWG solid copper wire leads 48 inches in length with U.L. Style 116666 direct burial insulation.

These IR models are used in below grade applications such as irrigation, municipal, and groundwater monitor-

ing.  All 200 series sensor electrical components are self-contained. Pressure/temperature ratings for the

various models are contained in the 

Specifications

 section of this manual. These models can be further de-

scribed as follows:

"Standard" Sensor

Designed for indoor or protected area applications such as HVAC, pump control, and industrial process monitor-

ing where the flow rates are between 0.5-30 feet/second and temperatures are below 221°F.  Standard sensors

are supplied with 20 feet of 2-conductor 20 AWG shielded U.L. type PTLC 105°C cable.

"IR" Sensor

Designed for below grade applications such as irrigation, municipal, and groundwater monitoring where the flow

rates are between 0.5-30 feet/second and temperatures are below 180°F. IR sensors are supplied with two

single conductor, 18 AWG solid copper wire leads 48 inches in length with U.L. Style 116666 direct burial

insulation.

PN# 72022

10/10/02  Rev E1

Содержание 200 Series

Страница 1: ...le so there is no need for recalibration after servicing or replacement Electronic Types Data Industrial provides several basic sensor configurations using the same impeller element This allows for a wide range of applications and pipe sizes Sensors are normally supplied with 20 feet of 2 conductor 20 AWG shielded U L type PTLC 105 C cable Optional sensors designated with the prefix IR feature two...

Страница 2: ...ons should be followed to ensure maximum system accuracy 1 Choose a location along the pipe where 10 pipe diameters upstream and 5 pipe diameters downstream of the sensor provide no flow disturbance Pipe bends valves other fittings pipe enlargements and reductions should not be present in this length of pipe 2 The preferred location for the sensor around the circumference of a horizontal pipe is o...

Страница 3: ...irements are as shown in the Specifications section Refer to Technical Bulletin 81 www dataindustrial com Electrical Installation IR sensors The sensor leads are supplied with watertight caps over the ends 1 DO NOT remove the plastic caps from the sensor leads until ready to splice See Application Note 47 and Technical Bulletin 52 www dataindustrial com 2 Use a twisted pair cable suitable for dire...

Страница 4: ...truments connected to the sensor are each rated either explosion proof or intrinsically safe these devices cannot be installed in a hazardous area The referenced installation drawing shows such apparatus located in a non hazardous location Proper interfacing between the hazardous and non hazardous areas must be provided It is of absolute importance that this interface be constructed and that all w...

Страница 5: ...Data Industrial Plastic Tee Type Flow Sensor Manual 5 ...

Страница 6: ...n calibrating an output board or when using the raw sensor data as direct output to interface with a device that is not a Data Industrial product Column 5 This column indicates the suggested flow range of each tee sensor Data Industrial sensors will operate both above and below the indicated flow rates However good design practice dictates the use of this range for best performance Sensors should ...

Страница 7: ...drop out 6 Inspect the shaft and bearings for wear and replace as necessary 7 Refer to Figure 1 To reinstall position the impeller in the cavity oriented as in Step 4 so that the impeller blades point into the flow direction The flow direction arrow on the top of the sensor housing should point downstream with the impeller blades pointing upstream 8 Carefully push the shaft through the housing and...

Страница 8: ...epeatability 0 3 of full scale over recommended design flow range for 228PV Linearity 0 2 of full scale over recommended design flow range for 228PV Transducer Excitation Quiescent current 600uA 8VDC to 35VDC max Quiescent voltage Vhigh Supply Voltage 600uA Supply impedance ON State VLow Max 1 2VDC 40mA current limit 15ohm 0 7VDC Output Frequency 3 2 Hz to 200 Hz for all except 228PF Output Pulse ...

Страница 9: ...to the other sensor input terminal Shorting across the sensor input terminals ON and OFF repeatedly allows the display to respond by trying to calculate a flow rate for the frequency of your shorting action If the display does not show a change from 0 00 it indicates a problem with the monitor 3 If the monitor tests ok and there are any splices in the cable break the sensor cable at the splice clo...

Страница 10: ...rovided by the Seller and does not cover limited life components such as bearings shafts impellers where wear rate is a function of application and environment Any component not manufactured by the Seller but included in its products shall not be covered by this warranty and is sold only under such warranty as the manufacturer may provide IfBuyerorPurchaserwishestomakeaclaimhereunder heshallsendwr...

Отзывы: