Maintenance ■ Workspace, Head and Gantry
- 102 -
Data I/O ■ 096-0465-001C
Cleaning the PSV5000 Machine
G
ENERAL
M
ACHINE
C
LEANING
General cleaning should be performed on a weekly basis. General
cleaning includes, but is not limited to, the following listed item.
WARNING: Vision hazard! Pressurized air or debris blown into
the eyes or skin could cause bodily damage. Always use care and
wear protective eye goggles when cleaning with pressurized air.
1.
Remove all dropped devices, debris, and other materials from all
working areas.
2.
With air and power OFF, remove all devices and materials that may
have fallen inside the machine.
3.
Use dry, compressed air to remove all dust and debris from the
work surface and from under the machine.
4.
Dust the safety doors, inside and outside, with an antistatic
cleaner.
5.
Wipe the top and side panels to remove grease, fingerprints, and
dust.
6.
Dust the top surfaces of the input/output modules.
C
LEANING THE
C
AMERA
C
OVER
Fingerprints and excessive amounts of dust or other residue on the
camera cover will affect the alignment.
If the camera can’t provide a good image, it may be an indicator that the
cover needs cleaning.
Wipe the camera glass in the work surface with a soft cloth and isopropyl
alcohol.
Содержание PSV5000
Страница 12: ......
Страница 36: ......
Страница 160: ......
Страница 161: ...Electrical Schematics for PSV5000 and Equipment ...
Страница 162: ......
Страница 163: ......
Страница 164: ......
Страница 165: ......
Страница 166: ......
Страница 167: ......
Страница 168: ......
Страница 169: ......
Страница 170: ......
Страница 171: ......
Страница 172: ......
Страница 173: ......
Страница 174: ......
Страница 175: ......
Страница 176: ...PROGRAMMABLE MEDIA EXPERTS ...