4.
Connect I
G202T-R38
bootloader adapter cable (delivered as additional accesory) at
IG202T-R38
RJ45
DIAG RS-232 port. Make sure that cable switch is at RUN position.
5.
Connect avaliable PC serial COM port and bootloader adapter cable with RS-232
communication cable (delivered as additional accesory).
6.
Start C2000Prog program by clicking the icon on the
Desktop.
7.
Select serial COM Port you are using (COM1, 2, 3 or
4). COM1 is selected in this example.
8.
Select Target: 2811_API2.10_30MHz.
9.
Skip Code Security Keys. All labels must hold initial
FFFF value.
Warning: Do not change these values
or modem DSP may be permanently locked, after
uploading of new firmware.
10.
Skip Flash Sector to be Erased.
11.
Tick Smart Sector Selection.
12.
Click at Program command button. File selection
dialog appeared. Select and open new firmware file.
File format is Intel hex, with
.hex
extension. File
name must be with
IG202T-R38xx
format, where
xx is
firmware version.
13.
When programming window appeared, change the
switch position at BSL, and reset modem by short
press at RST button on the front panel.
14.
At this point erasing and programming of modem flash must be observed. It may last about 20
to 30 seconds.
15.
When firmware upload is finished, close the programming dialog and exit C2000Prog program.
16.
Return the switch in RUN position, and perform the modem reset by short press at RST button
on the front panel.
17.
Now modem must be in data mode with PWR led ON and with new firmware in flash.
18.
You may now enter command mode (section 4.2 Entering Command Mode) and perform ATI
command to check version of loaded firmware.
IG202T-R38 User Manual v1.3
, Rev. date: 16 November, 2009
18