background image

18

Manual del Usuario / vantec series / User’s Manual

 

 

 

 

 

Troubleshooting

No  sound  from  the  unit.  The  input 
meters in the screen do not show any 
signal presence.

Full power cannot be obtained.
LIMIT  message  never  appears  in  the 
screen.

Sound  is  distorted.  INPUT  CLIP 
message is shown.

Sound is distorted.  LIMIT message is 
displayed.

Hum or buzz when a mixer is connected 
to the unit.

Hum  or  buzz  when  using  lighting 
controls in the same building.

The screen does not light up when the 
mains connector is connected and the 
power switch ON.

1 - Bad or loose AC connection to the 
unit or the mains outlet.
2 - Faulty AC cable.
3 - Blown Fuse.
4 - The mains voltage is out of range.
5 - Damaged amplifier.

1 - Check your connections.
2 - Check the cables, connectors and 
AC power with a suitable mains tester.
3 - Replace the blown fuse with another 
of the same type and size. 
4 - If the multimeter determines that the 
mains  voltage  is  out  of  the  range  you 
may  need  the  assistance  of  an 
electrician  to  find  an  appropriate 
solution.
5  -  Contact    a  qualified  tech  service 
center.

1 - T h e   c o n s o l e   p r o b a b l y   h a s 
unbalanced outputs. You may be using 
an  incorrect  unbalanced  to  balanced 
cable.
2 - The mixer and the powered speaker 
are  not  plugged  into  the  same  mains 
outlet.
3 - The audio signal cable is too long or 
too close to an AC cable.

1-The audio signal cable is too long or 
too close to the lighting cable.
2 - On a sound system with three phase 
AC, the lighting equipment and the unit 
are connected to the same phase.

1-  Move  the  audio  signal  cable  away 
from  lighting  cables.Try  to  find  out  at 
what point the noise is leaking into the 
system.
2  -  Connect  the  sound  system  to  a 
different phase than the lights. You may 
need the help of an electrician.

1-Read the appendix of this manual to 
make a correct unbalanced to balanced 
cable.
2 - Connect the mixer and the unit to the 
same mains outlet.
3  -  Use  a  cable  that  is  as  short  as 
possible and/or move the audio signal 
cable away from mains cables.

The  system  is  overloaded  and  has 
reached maximum power.

1 - Turn down the mixer´s output.
2 - Turn down the master output volume 
in the unit.

1-The  mixer  or  signal  source  is 
distorting.
2 - The output level from the mixer is too 
high.
3 - Input gain controls are set too high.

1-Turn  down  the  mixer´s  output  and 
check no channels are distroting. 
2 -Turn down the mixer´s output.
3 - Turn down input gain controls.

1  -  The  signal  source  does  not  have 
enough ouput level.
2 - Input gain controls are at very low 
volume.
3 - Master Volume is very low.

1 - Use balanced outputs of a mixer.
Rise  master  ouput  volume  of  the 
source.
2 - Set up input gain controls at higher 
positions.
3 - Increase Volume by turning up the 
Master Volume control.

1  -  The  signal  source  is  sending  no 
signal.
2 - Input gain controls are at minimum 
position.
3 - Defective cable.
4 - If Wireless Audio is connected input 1 
which  controls  audio  is  at  mimimum 
position  or  Volume  of  the  source  is 
muted. 

1 - Check that the source is not muted 
and is sending signal to the unit.
2 - Check input gain controls. Put them 
at 0dB.
3 - Check that the cable from the source 
to  the  unit  is  connected  correctly. 
Replace the cable if defective.
4 - Adjust Volume of input gain control 
number one.

Содержание Vantec-118A

Страница 1: ...tes de utilizar el equipo lea la sección Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference ...

Страница 2: ...io vantec series User s Manual INTRODUCTION LINE DRAWINGS 3 4 5 11 11 24 12 18 19 23 AMPLIFIERS SPECIFICATIONS RIGGING SYSTEM ANNEX Description ON OFF Overload indicator Overheating Equalisation Low mains voltage Current consumption CONFIGURATIONS Troubleshooting Line connections unbalanced and balanced SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY ...

Страница 3: ...o If the apparatus is connected permanently the electrical system of the building must incorporate a multipolar switch with a separation of contact of at least 3mm in each pole El colgado del equipo sólo debe realizarse utilizando los herrajes de colgado recomendados y por personal cualificado No cuelgue la caja de las asas The appliance should be flown only from the rigging points and by qualifie...

Страница 4: ...aración en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authori...

Страница 5: ...io video and similar electronic apparatus Safety requirements l EN 55032 2012 Electromagnetic compatibility of multimedia equipment Emission requirements l EN 55103 2 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of e...

Страница 6: ...ic birch plywood and finished with the DAS ISO flex coating Power is supplied by a cutting edge 1500 Wpeak Class D amplifier in a biamplified configuration driving a single DAS 12F4C loudspeaker and twin M 60 compression drivers Features The VANTEC 20A and VANTEC 118A powered multifunction systems combine DAS s reputation for performance and reliability with the latest technological innovations of...

Страница 7: ...R Accessories 2 TRD 6 Stacking bracket for VANTEC 218A max 4 u max 1 u using TRD 6 TRD 2 black Speaker cabling SC 2 2m XLR microphone signal balanced cable 2 Units 2 x VANTEC 20A 2 x VANTEC 218A Manual del Usuario vantec series User s Manual ...

Страница 8: ...k Speaker cabling SC 1 1m XLR microphone signal balanced cable 6 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 4 6 x VANTEC 20A 2 x VANTEC 118A Manual del Usuario vantec series User s Manual 2 PL VT20S Steel transport dolly for VANTEC 20A max 4 u black 1 PL VT118S Wooden transport dolly for VANTEC 118A max 2 u black ...

Страница 9: ...NTEC 20A max 5 u black Speaker cabling SC 1 1m XLR microphone signal balanced cable 4 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 4 2 PL VT20S Units Processors 1 DSP 2060A 2 In 6 Out fully configurable DSP 9 full bandwidth parametric band EQ on each channel AudioCore DASnet equipped Manual del Usuario vantec series User s Manual ...

Страница 10: ...R microphone signal balanced cable 6 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 6 Units Processors 1 DSP 2060A 2 In 6 Out fully configurable DSP 9 full bandwidth parametric band EQ on each channel AudioCore DASnet equipped POWER POWER 2 PL VT20S 2 PL VT118S 6 x VANTEC 20A 4 x VANTEC 118A Manual del Usuario vantec series User s Manual ...

Страница 11: ... series User s Manual 1500 Wpeak Class D Bi amp Balanced Differential Line Line 20kOhms Line 3 V 12dBu 63 Hz 20 kHz 90º Nominal 15º Nominal 135 dB LF 1 x 12F4C GM 12F4 HF 2 x M 60 GM M60N Trapezoidal 7 5º Birch Plywood Black ISO flex Paint Integrated in box design INPUT 1 x Female XLR LOOP THRU 1 x Male XLR AC INPUT 1 x PowerCon AC OUTPUT 1 x PowerCon 3 0A 115V 50 Hz 60 Hz 1 5A 230V 50 Hz 60 Hz 33...

Страница 12: ...sing THRU HPF 3 LIMIT Red LED indicates amplifier saturation Amplifier limiter indicator lights 4 SIGNAL Green LED indicates signal presence 5 ON Green LED indicates that the unit is ON 6 SUB LEVEL Potentiometer for adjusting the unit level 7 AC INPUT Standard PowerCon NAC3FCA mains connector inserted rotated and locked for ON Only use this equipment with an appropriate mains cord 8 THRU HPF SATEL...

Страница 13: ...he array Rotate the encoder to select the option needed and press again to confirm Use the same Number Of Units IN ALL the cabinets of your system Once the input source has been connected to the amplifer s cabinet the user has to check the gain structure of the system Adjust level output from your processor and or mixing console in order to prevent INPUT CLIP left signal meter As well try to avoid...

Страница 14: ... HPF off HPF off THROW Mid Press the encoder Rotate the encoder and press to confirm one of the following HPF options off 63Hz V118A 100Hz User MUST enable the SAME HPF in ALL cabinets forming the array In order to have more dynamic headroom in the system when used with subs HPF at V118A position with Vantec subwoofers or 100Hz is highly recommended Press the encoder and rotate it until THROW is s...

Страница 15: ...AVE R mode connection Select Mode SINGLE L R MASTER L DASlink MASTER L CONTINUE Wait a minute SLAVE R SINGLE Mode Master Slave Adding Slave Unit CREATE NEW LINK Select Mode SLAVE R CREATE NEW LINK CREATE NEW LINK Waiting MASTER Searching for SLAVE connection Altea unit Wait a minute Wait a minute Master cabinet Master cabinet Master cabinet Master cabinet Only Wireless Audio Wireless Audio Control...

Страница 16: ... B User can LOCK the Display and the encoder WITH PASSWORD by enabling this option MENU LOCK pw292 In case A to unlock just press the encoder In case B to unlock PUSH encoder and enter the 3 digit password 292 STAND BY When no signal is detected the amplifer shuts down Time can be selected OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIO...

Страница 17: ... for several seconds after the mains power has been disconnected Low mains voltage If mains voltage falls below the shutdown voltage for the unit it will stop playing When acceptable levels are regained the unit will switch back on automatically Therefore the current consumed by a 115V version is double the 230V version to achieve the same acoustic power level Normally it is enough just to let the...

Страница 18: ...hase 1 Move the audio signal cable away from lighting cables Try to find out at what point the noise is leaking into the system 2 Connect the sound system to a different phase than the lights You may need the help of an electrician 1 Read the appendix of this manual to make a correct unbalanced to balanced cable 2 Connect the mixer and the unit to the same mains outlet 3 Use a cable that is as sho...

Страница 19: ...g set up and teardown Only experienced installers with adequate knowledge of the equipment and local safety regulations should fly speaker boxes It is the user s responsibility to ensure that the systems to be flown including flying accessories comply with state and local regulations The working load limits in this manual are the results of tests by independent laboratories It is the user s respon...

Страница 20: ...NTEC 118A as VANTEC 118A and VANTEC 20A Moving the lower trigger up 1 reveals the slide that will fall by its own weight 2 When releasing the trigger it will return to its place and the slide will remain fixed 3 Similarly to hide the slide we must act on the trigger as in 1 and push the slide up 4 releasing the trigger 3 finally Now if we attach this enclosure to another VANTEC 20A we will hear a ...

Страница 21: ... a maximum of 5 units of VANTEC 20A It has 11 hook points for the lifting slings numbered from front to back see attached figure To assure the vertical inclination of the entire column use the Ease Focus software which will indicate which holes have to be used This frame will be joined to the first box of the column as if it were another enclosure and will be locked when a clack is heard The other...

Страница 22: ...ide that allows a box angle between 25º and 10º when placed on a TRD 2 tripod or on a TRD 6 pole It is only possible to use one unit in this way The VANTEC 118A and VANTEC 218A enclosures have a socket for aTRD 6 pole 25º 7 5º 10º TRD 6 TRD 6 TRD 2 VANTEC 218A Example of VANTEC 20A on VANTEC 218A with TRD 6 VANTEC 20A ...

Страница 23: ...nd the platform The other boxes will be joined by interlocking PL VT118S The platform PL VT118S with WLL 150 kgf allows transport of up to 3 stacked units of VANTEC 118A It is necessary to be very careful when moving the assembly since the enclosures are not fastened by interlocking to the platform although one VANTEC 118A can be interlocked with another since they have slides equal to those of th...

Страница 24: ...ed by the shield affects both signal conductors in the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors that can carry balanced signal have three pins such as XLR Cannon and 6 35mm stereo The graphs that follow show the re...

Страница 25: ...8 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134 0860 DAS do Brasil LTDA Rua Dos Andradas 382 SL Santa Efigênia São Paulo Brasil CEP 01208 000 Tel 551133330764 ...

Отзывы: