DAS Action Series Скачать руководство пользователя страница 17

17

  

  

  

  

  

  

  

  

Manual del Usuario

 / action 500 series / 

User’s Manual

1 2

live

off

0.0m

O

+ 2 dB

1

C

2

live

off

0.0m

O

INPUT 

CLIP

1

L

2

live

off

0.0m

O

LIMIT

MAIN MENU

BACK

PRESET: Live

HPF: Off

1 2

live

off

0.0m

O

0 dB

live preset

MAIN MENU

BACK

PRESET: Live

HPF: Off

MAIN MENU

BACK

HPF: Off

PRESET:

 

Live >

MAIN MENU

BACK

HPF: Off

PRESET:

 

<dance>

MAIN MENU

BACK

HPF: Off

PRESET:

<monitor>

Differences between Presets

DISPLAY (except 

ACTION-S18A

ACTION-S118A

 & 

ACTION-S218A

)

1 2

live

off

0.0m

O

0 dB

 

ADJUSTING THE LEVELS:

 

By  default  the  state  of  the  screen  is  the 

following:

 

Once  the  input  source  (s)  have  been 

connected to the amplifier´s cabinet, the user has 
to adjust the levels.
 

For the two input channels (1 and 2), two 

independent  gain  controls  are  available.  Be 
careful when setting the input volume and do not 
exceed the maximum level shown on the meters: 
(input clip shown on channel one)

peak
meters

RMS
meter

Exceeding the limits
may cause
speaker failure!!

Exceeding the limits
may cause
speaker failure!!

 

After  having  set  the  input  volume  values 

under  the  maximum  level,  user  has  to  adjust 
ouput volume with the master control. The level 
is shown in the right meter of the screen. As with 
the  inputs be  careful  not  exceeding the  limit: 
(LIMIT shown)

 

After  these  two  volume  adjustments  the 

screen  will  show  something  like  this  (when 
having the input sources ON):

It  is  highly  recommendable 
working with output volume 
below 0dB. If maximum level 
is  required  user  should 
increase  the  output  level 
(higher than 0dB)

 

MAIN MENU:

 

As stated previously by pushing the encoder 

the user can access to the following options in 
the MENU:

 

Note: to enter and select and option always push the encoder. For going back in the menu, the user 

has to select 

Back

 on the screen and press the encoder or just pushing the encoder.

 

After 30 seconds without using the unit it will go back to the main screen automatically.

 

PRESETS:

 

Three  factory settings (

live,  dance,  monitor

depending on the type of music/use that has 
been configured inside the unit:

 

With the encoder go to Preset Sub-menu and 

press the knob to access to the different options:

Notes:

 

The only models in this series that do not 

have a display are: 

ACTION-S118A

 and 

ACTION-

S218A

.

 

In  the  model 

ACTION-M512A

  the  preset 

activated  by  default  is  "Monitor"  while  in  the 
other models it is "Live". While your preset is 
"Monitor"  the  display  will  turn  off  completely 
during use.

 

If in the "LOGO" menu we have chosen the 

"Limit" option, the anagram will flash when the 
limiter is activated. If we have chosen "On" it will 
remain lit, while if the option chosen is "Off" it 
will remain off.

10k

5k

2k

1k

500

200

100

50

20

20

20k

d

B

S

P

L

10k

5k

2k

1k

500

200

100

50

20

20

20k

d

B

S

P

L

10k

5k

2k

1k

500

200

100

50

20

20

20k

d

B

S

P

L

Live

Dance

Monitor

Содержание Action Series

Страница 1: ...ridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference ACTION 508A ACTION 512A ACTION M512A ACTION 515A ACTION 525A ACTION S18A ACTION S118A ACTION S218A ...

Страница 2: ...ent consumption CONFIGURATIONS Troubleshooting Line connections unbalanced and balanced SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY Manual del Usuario action 500 series User s Manual 2x ACTION 508A 1x ACTION S18A 2x ACTION 512A 2x ACTION S18A 2x ACTION 515A 1x ACTION S118A 2x ACTION 525A 2x ACTION S218A 17 21 Adjusting the levels Main Menu System presets HPF High Pass Filter Delay Option...

Страница 3: ...nte la instalación eléctrica del edificio debe incorporar un interruptor multipolar con separación de contacto de al menos 3mm en cada polo If the apparatus is connected permanently the electrical system of the building must incorporate a multipolar switch with a separation of contact of at least 3mm in each pole No desconecte la tierra en el conector de alimentación pues es peligroso e ilegal Equ...

Страница 4: ...ación en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authorise...

Страница 5: ...ocumentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Cumple con los objetivos esenciales de las Directivas Abide by essential objectives relating Directives l de Baja Tensión Low Voltage Directive 2014 35 UE l de Compatibilidad Electromagnética EMC 2014 30 UE l RoHS 2011 65 UE l RAEE WEEE 2012 19 UE Manual del Usuario action ...

Страница 6: ...nience Whether it is in a high profile venue or on the stage of a major event the action 500 series will provide the power and definition needed to make your performance a success 6 ACTION 508A Compact multi purpose system with monitor position 8 bass loudspeaker 8GV 1 5 VCD Compressor driver with titanium diaphragm M 34 1 4 VCD Reduces size and weight Pole mount socket The ACTION 508A offers a mu...

Страница 7: ...et permits mounting full range systems above the ACTION S18A and two bar handles makes moving easy ACTION S218A High output bass reflex powered subwoofer system Twin 18 loudspeakers 18FW4 3 VCD Durable black paint finish Side located bar handles This bass reflex powered subwoofer system uses dual 18 bass loudspeakers equipped with 3 voice coils The exceptional power handling capacity and efficienc...

Страница 8: ...o Group S L Valencia Made in Spain ACTION series 5oo CH 1 MAX oo 0 CH 2 MAX oo 0 INPUT 1 INPUT 2 AUX IN MIC LINE MIC LINE OUTPUT MIX CH 1 CH 2 Made in Spain GAIN www dasaudio com AUDIO MANAGEMENT PUSH FOR DSP VOLUME DAS Audio Group S L Valencia ACTION series 5oo Select HPF High Pass Filter SUB mode in the Action 508A Select LPF Low Pass Filter Top mode in the Action S18A 1 2 live Sub 0 0m O 0 dB 1...

Страница 9: ...DAS Audio Group S L Valencia Made in Spain ACTION series 5oo Select LPF Low Pass Filter Top mode in the Action S18A CH 1 MAX oo 0 CH 2 MAX oo 0 INPUT 1 INPUT 2 AUX IN MIC LINE MIC LINE OUTPUT MIX CH 1 CH 2 Made in Spain GAIN www dasaudio com AUDIO MANAGEMENT PUSH FOR DSP VOLUME DAS Audio Group S L Valencia ACTION series 5oo Select HPF High Pass Filter SUB mode in the Action 512A 1 2 live Sub 0 0m ...

Страница 10: ... FIRE REPLACE ONLY WITH THE SAME TYPE DAS Audio Group S L Valencia MADE IN SPAIN Model ACTION S118A 230 MAX 7 UNITS ACTION 118A 230 AC OUTPUT ACTION series 5oo OFF ON LOGO 0 80Hz 80Hz LOW PASS FOR ACTION 500 TOPS CH 1 MAX oo 0 CH 2 MAX oo 0 INPUT 1 INPUT 2 AUX IN MIC LINE MIC LINE OUTPUT MIX CH 1 CH 2 Made in Spain GAIN www dasaudio com AUDIO MANAGEMENT PUSH FOR DSP VOLUME DAS Audio Group S L Vale...

Страница 11: ...UT B HPF THRU SATELLITE X OVER DEEP LOUD PRESET POLARITY LIMIT SIGNAL ON CAUTION DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISK OF ELECTRIC SHOCK DO NOT OPEN T10 A L 250V FUSE FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE DAS Audio Group S L Valencia MADE IN SPAIN Model ACTION S218A 230 MAX 4 UNITS ACTION 218A 230 AC OUTPUT OFF ON LOGO ACTION series 5oo LEVEL...

Страница 12: ...TION 515A ACTION 525A ACTION S18A ACTION 512A Bottom View Right View Front View Rear View Rear View Top View Right View Front View Rear View Bottom View Right View Front View Bottom View Right View Front View Rear View Right View Left View Front View Rear View 14 ACTION 508A Rear View Left View Front View Top View ...

Страница 13: ... Hz 60 Hz 230V 1 1A 50 Hz 60 Hz 71 8 x 44 4 x 37 5 cm 28 3 x 17 5 x 14 8 in 24 kg 52 8 lb ANL 2 TRD 2 TRD 6 TRD 7 Model Power Amplifier Input Type Input Impedance Sensitivity Frequency Range 10 dB HF Horn Coverage Angles 6 dB Maximum Peak SPL at 1m Transducers Replacement Parts Enclosure Material Color Finish Connectors AC Power Requirements Dimensions H x W x D Weight Accessories ACTION 525A 1000...

Страница 14: ...necting external audio media devices such as MP3 players The input source is controlled with Gain control 1 8 AC INPUT Standard IEC 60320 only ACTION S18A or PowerCon NAC3FCA mains connector inserted rotated and locked for ON Only use this equipment with an appropriate mains cord 9 AC OUTPUT only ACTION M512A ACTION S118A andACTION S218A PowerCon NAC3FCB connector for AC loop thru to other units s...

Страница 15: ... indicator LIMIT LED that lights when the signal is excessive The indicator should not be lit continuously This distorts the signal quickly fatiguing your ears and may damage the speakers Therefore it is recommended that you never work with this LED on at most it should blink only occasionally Equalisation The unit does not need extreme settings of equalisation to produce quality sound Avoid high ...

Страница 16: ... Faulty AC cable 3 Blown Fuse 4 The mains voltage is out of range SOLUTION 1 Check that the mixer or sound source is sending signal to the UNIT 2 Check that the cable from the sound source to the UNIT is connected correctly Replace the cable if defective 3 Allow the unit to cool down for some minutes and it will function again Check the main output level of the mixer or channel gains since the uni...

Страница 17: ...screen will show something like this when having the input sources ON It is highly recommendable working with output volume below 0dB If maximum level is required user should increase the output level higher than 0dB MAIN MENU As stated previously by pushing the encoder the user can access to the following options in the MENU Note to enter and select and option always push the encoder For going ba...

Страница 18: ...elay 9 9m MAIN MENU BACK OPTIONS Delay 0 0m MAIN MENU BACK PRESET Live HPF Off MAIN MENU MAIN MENU BACK BACK PRESET Live PRESET Live HPF Off HPF SUB when combining with subwoofer ACTION S18A ACTION S118A or ACTION S218A DELAY The user can set up a delay in the cabinets by using the delay Sub menu from 0 to 9 9m in 0 1m steps Delay units can be selected between meters or feet BACK OPTIONS ...

Страница 19: ...RAST 10 CONTRAST 10 DIMMING on DIMMING on DIMMING on DIMMING off DIMMING on DIMMING on DIMMING on STAND BY off STAND BY 5min DLY UNITS m DLY UNITS ft Preset live HPF off Delay 0m Stand By off Dimming On DIMMING When active the screen lowers its luminosity after a few seconds Default is on 1 2 live off 0 0 0m O 0 dB LOCKED PUSH TO UNLOCK 1 2 live off 0 0 0m O 0 dB LOCKED PUSH TO UNLOCK 1 2 live off...

Страница 20: ...0 dB loud preset MAIN MENU MAIN MENU MAIN MENU BACK BACK BACK PRESET loud LPF Top LPF Top LPF Top PRESET loud PRESET deep MAIN MENU MAIN MENU MAIN MENU BACK BACK BACK PRESET loud PRESET loud PRESET loud LPF Low Pass Filter There are 3 different options LPF Top LPF 63Hz LPF 100Hz Combination with ACTION 508A ACTION M512A ACTION 512A ACTION 515A and ACTION 525A 10k 5k 2k 1k 500 200 100 50 20 20 20k ...

Страница 21: ... O 0 dB OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU RESET DEVICE Are you sure DLY UNITS m DLY UNITS m NO YES INFORMATION INFORMATION INFORMATION INFORMATION RESET DEVICE RESET DEVICE RESET DEVICE RESET DEVICE DLY UNITS m DLY UNITS ft Password 0 0 0 1 2 loud Top 0 0m O 0 dB 1 2 loud Top 0 0m O 0 dB 0dB LOCKED PUSH TO UNLOCK 0dB UNLOCKED Preset loud LPF Top LOGO on MENU LOCK off Dimming on O...

Страница 22: ... 1 safety factor When flying a system the working load must be lower than the resistance of each individual flying point in the enclosure as well as each box Hanging hardware should be regularly inspected and suspect units replaced if in doubt This is important to avoid injury and absolutely no risks should be taken in this respect It is highly recommended that you implement an inspection and main...

Страница 23: ... 726 lb If using other hardware make sure it is rated to handle the required load When using eyebolts it is important to bear in mind that the rated working load is only true for a load applied in the plane of the eye and is significantly reduced for other angles The drawing illustrates the concept The table shows the variation of the working load as a function of the load angle In the case of the...

Страница 24: ... Do not use on surfaces such as plaster and gypsum It is highly recommended and in most parts of the world mandatory that a safety cable be used to secure the enclosure to the structure To ensure optimum safety the installation should be checked thoroughly at regular intervals replacing all deteriorated elements Loosen the screws before reorienting the speaker Never force the rigging elements Cont...

Страница 25: ...n the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors that can carry balanced signal have three pins such as XLR Cannon and 6 35mm stereo The graphs that follow show the recommended connection with different types of conn...

Страница 26: ...88 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134 0860 DAS do Brasil LTDA Rua Dos Andradas 382 SL Santa Efigênia São Paulo Brasil CEP 01208 000 Tel 551133330764 ...

Отзывы: