R e v . 0 4
© 2 0 1 4 D a r f o n A m e r i c a C o r p .
9
| P a g e
M I G 3 0 0 M I C R O I N V E R T E R
I N S T A L L A T I O N M A N U A L
Step 5: Ground the Micro Inverters
Option 1: Integrated Grounding. Go to step 6. No additional grounding is needed.
Option 2: GEC Grounding. Unscrew the top of grounding clips on the micro inverters. Run the grounding
electrode conductor to each grounding clip on the micro inverter and then to the junction box.
After laying out the grounding conductor, secure the top of the grounding clips back onto the
micro inverters.
WARNING
Correct AC grounding and short circuit protection
must be provided to ensure operational safety.
Step 6: Connect the Micro Inverters
6.1 Remove the temporary shipping cap from the t-branch on the AC trunk cable and connect the
micro inverter. Ensure the connection is secure and locked into place.
WARNING
Do not remove the shipping/dust-protection cap until
the MIG300 is ready to be installed to the trunk cable.
6.2 Repeat for all micro inverters in the AC branch circuit.
6.3 For any unused connectors on the AC trunk cable, replace the temporary shipping cap with a
Sealing Cap. Listen for a click as the Sealing Cap is connected to ensure that it is securely locked
into place.
Содержание MIG300
Страница 1: ...INSTALLATION MANUAL MIG300 MICRO INVERTER...