background image

 

  

 

 

   

 

Xi-12B 

Ordercode: D3442/D3443 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

Avoid installing your equipment very near radio or TV sets, mobile phones, etc., as these can cause 
RF (radio frequency) interference. 

 

Before changing your grounds around, always turn your amplifiers down. 

 

Do not connect this device to a dimmer pack. 

 

Do not drive the inputs with a signal level higher than required to drive the equipment to full output. 

 

Do not open this device. Risk: hazardous radiation exposure. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Extreme frequency boosts in connection with a high input signal level may lead to overdriving your 
equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT 
control. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the 
system switched off until it has reached room temperature. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure that there is sufficient room on all sides of the system for air circulation. 

 

Make sure you do not use the wrong kind of cables or defective cables. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear. 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Only use device indoors, avoid contact with water or other liquids. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the input 
mode switch. 

 

Prevent distortion! Make sure that all components connected to the Xi-12B have sufficient power 
ratings. Otherwise distortion will be generated because the components are operated at their limits. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

The best way (even if not always feasible) to avoid ground loops is to connect the electric ground of 
all the equipment to a single central point (“star” system). In this case, the central point can be the 
mixer. 

 

To avoid or solve hum and buzzing troubles, try different combinations of lifting grounds on units that 
are supplied with ground lift switches or make sure all chassis are connected to earth ground, either 
through the A.C. power cord ground or by the front panel rack mount screws. 

 

To emphasize a frequency range, you do not necessarily have to move its respective slider upwards; 
instead, try lowering surrounding frequency ranges. This way, you avoid causing the next piece of 
equipment in your sound path to overdrive. You also preserve valuable dynamic reserve 
(“headroom”). 

 

When connecting the other parts of your sound system, watch out for the so-called “ground loops”. 

 

WARRANTY: Till one year after date of purchase. 

 

Operating Determinations 

 

If this system is operated in any other way, than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 

 

You endanger your own safety and the safety of others! 

 

Improper installation can cause serious damage to people and property! 

 

 

Содержание Xi-12B

Страница 1: ...Xi 12B V1 Ordercode D3442 D3443 MANUAL Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands ENGLISH...

Страница 2: ...onnection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Backside 6 Installation 6 Set Up and Operation 7 System Setup Example 8 x Xi 3 and 2 x Xi 12B 7 Connection...

Страница 3: ...instructions of this manual Before you initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintain...

Страница 4: ...ming signals should be clear Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never remove warning or infor...

Страница 5: ...roper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your a...

Страница 6: ...mpedance 4 Continuous power 300W Program power 600W Peak power 900W Components 12 woofer with 2 5 VC Frequency response processed 42 150 Hz Frequency response flat 10dB 42 2800 Hz Recommended HPF 42Hz...

Страница 7: ...HRU This output is connected in parallel with the Speakon input 01 and can be used for powering another speaker Fig 03 Installation Remove all packing materials from the Xi 12B Check if all foam and p...

Страница 8: ...he high pass outputs on your digital crossover with the dedicated inputs on your amplifier 03 Connect the low pass outputs on your digital crossover with the dedicated inputs on your amplifier 04 Use...

Страница 9: ...reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Headphone Unbalanced Balanced F...

Страница 10: ...hooting This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit operates properly do not car...

Страница 11: ...10 Xi 12B Ordercode D3442 D3443 Dimensions...

Страница 12: ...2018 DAP Audio...

Отзывы: