background image

 3

• 

Always operate the unit with the AC ground wire connected to the electrical system ground.  

• 

Connecting amplifier outputs to oscilloscopes or other test equipment, while the amplifier is in 
bridged mode, may damage both the amplifier and test equipment. 

• 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full output. 

• 

Please turn off the power switch, when changing the power cord or signal cable, or select the input 
mode switch. 

• 

In typical use, Please set the volume to 0dB position. 

• 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

• 

For replacement use fuses of same type and rating only. 

• 

Prevent distortion! Make sure that all components connected to the Vision have sufficient power 
ratings. Otherwise distortion will be generated because the components are operated at their limits. 

• 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the same  
electrical circuit to ensure the same phase! 

• 

If system is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

• 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the 
system switched off until it has reached room temperature. 

• 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

• 

WARRANTY: Till one year after date of purchase. 

 

OPERATING DETERMINATIONS 

 
If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 
 
You endanger your own safety and the safety of others! 
 

Improper installation can cause serious damage to people and property !

 

 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

• 

In system setup, the amplifier's output power must be 50%-100% more than the loaded 
loudspeakers rated power. 

Содержание Vision 1600

Страница 1: ...Vision Vision 1600 ORDERCODE D4151 Vision 3500 ORDERCODE D4153 Vision 2400 ORDERCODE D4152...

Страница 2: ...need You can rely on DAPAudio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work...

Страница 3: ...0 3500 Product Guide Warning Safety instructions Operating Determinations Description Features Overview Front side Overview Back side Installation Set Up and Operation Connecting VISION 1600 Connectin...

Страница 4: ...e mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Do not insert objects into air vents Do not connect this system...

Страница 5: ...to connect the power amps and the mixing console to the same electrical circuit to ensure the same phase If system is dropped or struck disconnect mains power supply immediately Have a qualified engi...

Страница 6: ...1V and 1 4V Bridge parallel or stereo mode 30 Hz Hi pass filter 3 dB 18 dB oct Ground selector Switch able crossover Low pass 150 Hz 18 dB oct Back to front airflow Amplifier has softstart and separat...

Страница 7: ...your mixer and turn down the input gain control Please keep in mind that the power amplifier cannot correct any distortion 4 Channel 1 Volume Control In stereo mode this potentiometer allows the adjus...

Страница 8: ...he power Amplifier is ready to work 7 SIGNAL Indicator The illumination of the LED only indicates a safe operation 8 Handles Handles are used for easy transportation 9 Power Switch Use this switch to...

Страница 9: ...his part is the air entrance Don t obstruct it 19 High Pass Filter Selector This switch is used to cut low frequency under 30Hz infrasound 20 Channel 2 Link Socket This balanced socket is used to link...

Страница 10: ...e product specification voltage Do not attempt to operate a 120V specification product on 240V power or vice versa Install this device on a flat surface not bending or curved Do not supply power befor...

Страница 11: ...ume can be adjusted by means of the two potentiometers Connect the 2 turn lock outputs to the 2 speakers Bridge mode In this mode connect the input CH1 to your mixer s outputs Put the selector on the...

Страница 12: ...tereo mode In this mode connect the 2 inputs CH1 and CH2 to your mixer s outputs Put the selector on the stereo position Output volume can be adjusted by means of the two potentiometers Connect the 2...

Страница 13: ...olume can be adjusted by means of the two potentiometers Connect the 2 turn lock outputs to the 2 speakers Bridge mode In this mode connect the input CH1 to your mixer s outputs Put the selector on th...

Страница 14: ...The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse...

Страница 15: ...atio 30V us 40V us 44V us DAMPING Factor 400 300 300 S N Ratio 95dB 95dB 95dB Input sensitivity 0 775V 1V 1 4V Input imped bal unbal 20KW Protection overheat short circuits DC limit and softstart Outp...

Страница 16: ...2003 DapAudio...