background image

 

Frontpanel 

 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

        

 
 
 
        

 

 

 

 

 

 

 

 

 

 

 

 

         

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

          

Fig. 2 

 
  
1. CH1 volume control 

    In bridge mode, this attenuator controls the volume of two channels. CH2 attenuator has no function. 
    In stereo or parallel mode, this attenuator just controls CH1 volume. 
    Gain control range: -8 ~, continuous control. 
    Gain control range: -8 ~ 0dB, 40 steps control, effective rotation angle is 280 degrees. 

2. Protection LED

 

    The Protection LED indicates that one or more critical issues require your attention. The amplifier is    
    protected against overheat, overload, DC and short circuit. When the LED is lit, check the amplifier for  
    these problems and provide an adequate solution. 

3. Over-heat indicator 

    The over-heat LED will light when the internal temperature of the amplifier exceeds 105 degrees Celsius.   
    At the same moment, the over-heated channel might automatically be switched off in order for the  
    amplifier to cool down. When the over-head LED is lit, be sure to check the air circulation at the front  
    and the back of the amplifier. 

4. Clip indicator 

    The Clip Indicator LED will light when over-modulation of the audio signal is detected. Although the  
    amplifier has a built-in clip limiting circuit, any illumination of the Clip indicator LED indicates that the  
    input level should be reduced.  

5. Signal indicator 

    The signal LED indicates that an audio signal is present at the amplifier input. The sensitivity of this LED is  
    0,35V or -9 dB. Illumination of this LED indicates correct functioning of the device. 

6.

 

Power LED. 

    Indicates that AC power is connected and the amplifier is turned on. 

7. CH2 volume control 
    

In bridge mode, this 

attenuator

 has no function, the volume is controlled by CH1 

attenuator

    In stereo or parallel mode, the 

attenuator

 just controls CH2 volume. 

    Gain control range: -8 ~ 0dB, 40 steps control, effective rotation angle is 280 degrees.

 

8.

 

AC Power Switch. 

    This is the main Power switch. Press to turn the amplifier on. 

9. Parallel indicator 

    When this LED is lit, means the amplifier is working in parallel mode . 

10. Bridge indicator 

      When this LED is lit, means the amplifier is working in bridge mode. 

11. Air entrance 

      Don't obstruct or insert objects into air vents.

 

12. Standby power indicator 

      The stand-by LED indicates that the amplifier is in Stand-by mode. When the amplifier is switched on,  
      the stand-by LED will stay illuminated for a few seconds, during which a self-test is performed. When  
      the self-test is completed, the stand-by LED dims. 

13.

 

Handles

 

      Handles are used for easy transportation. 
 
 
 

Содержание Stageamp 2.2

Страница 1: ...Stage Amp Stage Amp 2 2 ORDERCODE D4502 Stage Amp 2 6 ORDERCODE D4503 Stage Amp 4 0 ORDERCODE D4504 Stage Amp 4 4 ORDERCODE D4505...

Страница 2: ...DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you ou...

Страница 3: ...ting Determinations Return Procedure Claims Description Features and Overview Overview Front panel Overview Back panel Set Up and Operation Mode selection Stereo Mode Parallel Mode Bridge Mono Mode Re...

Страница 4: ...se make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintain perfect condition and to ensure a safe operation it is absol...

Страница 5: ...r Please read this manual carefully and keep it for future reference Remember that the amplifier has a better value on the market if you save the carton and all packing materials Always operate the un...

Страница 6: ...responsibility Highlite reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are g...

Страница 7: ...2 X 850W Stage Amp 4 0 RMS 2 X 3000W RMS 2 X 2000W RMS 2 X 1200W Stage Amp 4 4 RMS 2 X 3700W RMS 2 X 2500W RMS 2 X 1500W Features Clip limiting Thermal protection VHF protection Short circuit protecti...

Страница 8: ...ng circuit any illumination of the Clip indicator LED indicates that the input level should be reduced 5 Signal indicator The signal LED indicates that an audio signal is present at the amplifier inpu...

Страница 9: ...mation on polarity Connectors for each channel are in parallel the unused connectors may be used for linking to other amplifiers 19 CH1 Binding post output In stereo or parallel mode connect the negat...

Страница 10: ...tch to the Bridge position Apply the signal to Channel A s input and connect the speakers across the hot outputs the red binding posts of Channel 1 and 2 Channel 1 s hot output is in phase with the in...

Страница 11: ...n ordered DAP audio amplifiers shipped to customers are configured as follows North America 120VAC 60Hz Europe 230VAC 50Hz Asia 220VAC 50Hz 60Hz Australia 240VAC 50Hz South America 120VAC 60Hz or 220V...

Страница 12: ...t Channel A s input produces output at Channel A s output while the signal at Channel B s input produces output at Channel B s output Fig 4 Important Absolute minimum nominal load Impedance for stereo...

Страница 13: ...y channel A input may be used Use extreme caution when operating the amplifier In Bridged Mono Mode Never ground either side of the speaker cable when the amplifier Is in Bridged Mono Mode both sides...

Страница 14: ...ation is 4 Ohm per channel Absolute minimum nominal load Impedance for Parallel Stereo operation is 2 Ohm per channel 4 VHF protection If the amplifier output has reached a certain range and frequency...

Страница 15: ...s always to your advantage Periodically check that your cables are in good condition that they are correctly wired and that all their contacts are in good condition a great number of problems faulty c...

Страница 16: ...n the fuse cover Gently pry up the fuse cover The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was...

Страница 17: ...1 22V 26dB 32dB 38dB 5 47V 2 73V 1 36V Voltage gain 38dB 38dB 38dB 38dB Input impedance Balanced 20k unbalanced 10k Output circuit class 2 steps class H 3 steps class H 3 steps class H 3 steps class H...

Страница 18: ...16 STAGE AMP Block Diagram...

Страница 19: ...1 16 2 3 4 5 1 5 0 58 1 16 2 3 2 5 0 35 0 70 1 39 4 0 22 0 44 0 87 5 0 5 4 3 8 2 15 5 0 75 2 9 5 6 10 8 1 5 1 45 2 9 5 6 2 5 0 87 1 74 3 4 4 0 55 1 09 2 2 6 0 37 0 73 1 45 10 0 5 8 24 15 5 28 0 75 5 6...

Страница 20: ...load 5 18 0 81 1 61 3 2 16 0 51 1 02 2 14 0 32 0 64 1 28 12 0 2 0 4 0 8 10 0 128 0 25 0 51 10 18 1 61 3 2 6 2 16 1 02 2 4 14 0 64 1 28 2 5 12 0 4 0 8 1 6 10 0 25 0 51 1 01 40 18 6 2 11 9 22 16 4 7 7 1...

Страница 21: ...2009 DapAudio...

Отзывы: