19
ZA-9250VTU
Ordercode: D6155
Connecting Outputs
Speakers are connected by means of terminal connectors. See the examples below .
Low Impedance Outputs
You can use as many speakers as you want as long as the total impedance matches the amplifiers
output.
Example 1: Using the 8
Ω
output with an 8
Ω
speaker.
Fig. 08
Example 2: Using the 8
Ω
output with two 4
Ω
speakers.
Fig. 09
In a low impedance system, the total speaker load should always match the amplifier ’s
impedance, in order not to overload the amplifier. The total speaker power should be at
least equal to the power of the amplifier, to avoid speaker damage.
High Impedance Outputs
While using either the 70V outputs or the 100V outputs, note that all speakers
should be wired in parallel
.
The total power of all speakers summed together should never exceed the total power of
the amplifier in a 70V or a 100V system!