background image

 

12 

Approval 

 

The DAP D141473 and the D141482 are Class II wireless devices.

 

 

D141473: 740 - 752 MHz for use in:  

Austria, Belgium, Czech Republic, France, Germany, Hungary,  

 

 

 

 

 

Italy, Luxemburg, Netherlands, Poland, Romania, Slovakia,  

                                                                 Switzerland, Turkey, United Kingdom. 
D141482: 822 – 846 MHz for use in:  

France, Germany, Hungary, Italy, Netherlands, Romania, Sweden,  

 

 

 

 

 

Switzerland, And United Kingdom.  

 

Exclusion of liability 

The frequency tables in this publication are made according to national laws and regulations. The 
frequencies are checked on a regular basis. We don’t take any responsibility for eventual discrepancies 
between our listed frequencies and the frequencies actually approved in a given country. We strongly 
suggest you to inform in your own country or region for any changes or adaptions regarding the allowed 
frequencies. 
 

Be aware that in some countries, you are only allowed to partly use the frequency range of the device. 
Therefore, we strongly advice you to concult your authority as listed below:

 

 

Telecoms & Postal Regulatory Authorities in Europe 

Austria Rundfunk und Telekom Regulierungs-GmbH    

 

 

www.rtr.at 

Belgium Belgian Institute of postal services and telecommunications (BIPT)  www.bipt.be 
Czech Republic Czech Telecommunication Office   

 

 

www.ctu.cz 

Denmark National Telecom Agency   

 

 

 

 

www.tst.dk 

Finnland Finnish Communications Regulatory Authority (FICORA)    

www.ficora.fi 

France Autorité de Régulation des Télécommunications (ART)  

 

www.art-telecom.fr 

Germany Die Bundesnetzagentur 

 

 

 

 

 

www.bundesnetzagentur.de 

Greece National Telecommunications Commission (EET)    

 

www.eett.gr 

Hungary Communication Authority (HIF) 

 

 

 

 

 www.hif.hu 

Iceland Post and Telecom Administration (PTA)  

 

 

 

www.pta.is 

Ireland Commission for Communications Regulation (ComReg)  

 

www.comreg.ie 

Italy Italian Communications Authority (AGC)  

 

 

 

www.agcom.it 

Latvia Telecommunication State Inspection    

 

 

 

www.vei.lv 

Liechtenstein Office for Communications (AK) 

 

 

 

www.ak.li 

Lithuania Radio Administration  

 

 

 

 

 

www.rrt.lt 

Luxembourg Institut Luxembourgeois des Télécommunications (ILT)   

www.etat.lu/ILT 

Netherlands Onafhankelijke Post en Telecommunicatie Autoriteit (OPTA)   www.opta.nl 
Agentschap Telecom   

 

 

 

 

 

 

www.agentschap-telecom.nl 

Ministry of Economic Affairs    

 

 

 

 

 

www.ez.nl 

Norway Norwegian Post and Telecommunications Authority (NPT)    

www.npt.no 

Poland Urzad Regulacji Telekomunikacji (URT)  

 

 

 

www.urt.gov.pl 

Portugal Autoridad Nacional De Comunicaçòes (ICP-Anacom)  

 

www.anacom.pt 

Slovenia Agencija za telekomunikacije, radiodifuzijo in pošto  

 

www.atrp.si

Содержание D141473

Страница 1: ...COM 54 ORDERCODE D141473 740 752Mhz ORDERCODE D141482 822 846MHz...

Страница 2: ...manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant dap audio...

Страница 3: ...Return Procedure Claims Description Features Overview Frontview Rearview Installation Set Up and Operation Menu Options Sensitivity Adjustment Menu SQUELCH Signal Channel solution Menu Frequency Set M...

Страница 4: ...cable 100cm 1x mono jack cable 80cm User manual SAFETY INSTRUCTIONS Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of...

Страница 5: ...m time to time Please turn off the power of all equipment before making connections to other devices If system is dropped or struck disconnect the power adaptor immediately Have a qualified engineer i...

Страница 6: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our an...

Страница 7: ...141473 822 846 MHz ordernr D141482 4 channel wireless microphone system True diversity receiver Included 4 dynamic hand held microphones 32MHz Phase locked loop PLL circuit technology LCD display Easy...

Страница 8: ...all packing materials from the Com 54 Check that all foam and plastic padding is removed Put the 2 antennas into socket A and B at the backside in a vertical angle Remove the rubber protection caps a...

Страница 9: ...SQUELCH 0 40 dB in 5 dB steps 2 DISPLAY FREQU CHANNL 3 TUNE 785 100 811 000 in steps of 0 025 Hz 4 LOCK LOC OFF LOC ON Sensitivity Adjustment Menu SQUELCH Scroll through the menu by using the SET but...

Страница 10: ...he previous setup When you press UP DOWN the LCD indicates 2 modes either Channel or Frequency If you select channel CHANNL is shown as numerical value If you select FREQU it is shown as actual workin...

Страница 11: ...ton you can change the original state from LOC OFF to LOC ON the LCD will flash Press SET to store the setting the device is locked After storing pressing SET the LCD will stop flashing LOCK ON to LOC...

Страница 12: ...10dB 2 DISPL Choose between FREQU CHANNL TUNE 3 LOC Choose between LOC ON LOC OFF You can change your settings by pressing the UP DOWN buttons Be sure to store your desired setting by pressing the SET...

Страница 13: ...the batteries are fully charged the indicator Led will light GREEN When the LED flashes there is an error Remove the microphone for a moment from the charger and then place it back again 1 Charge LED...

Страница 14: ...f postal services and telecommunications BIPT www bipt be Czech Republic Czech Telecommunication Office www ctu cz Denmark National Telecom Agency www tst dk Finnland Finnish Communications Regulatory...

Страница 15: ...rnational B V Name Address Vestastraat 2 6468 EX Kerkrade The Netherlands This is the result of tests carried out on those 03 March 2005 samples of the product referred to above which were submitted f...

Страница 16: ...rnational B V Name Address Vestastraat 2 6468 EX Kerkrade The Netherlands This is the result of tests carried out on those 03 March 2005 samples of the product referred to above which were submitted f...

Страница 17: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Страница 18: ...ly dry before linking equipment or supplying electric power Troubleshooting DAP Audio COM 54 This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps b...

Страница 19: ...nt range 12 32dB S N Ratio 80dB Sensitivity 107dBM Stray control 75dB Output level balanced output 0 32dB Power 12 16V DC adapter included Current draw 300mA Dimensions 19 x 245mm X 1U LxWxH Weight 2...

Страница 20: ...2010 Dap Audio...

Отзывы: