background image

 

  

 

 

   

 

ACX-2 

Ordercode: D1905 

Connection with the mains 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

PHASE 

BLUE 

BLACK 

SILVER 

NEUTRAL 

 

YELLOW/GREEN 

GREEN 

GREEN 

PROTECTIVE GROUND 

 

Make sure that the device is always connected 

properly 

to the earth! 

 

Improper installation can cause serious damage to people and property! 

 

 

 

 

 

Return Procedure 

 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected] 

and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 

Содержание ACX-2

Страница 1: ...ACX 2 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D1905 MANUAL ENGLISH...

Страница 2: ...ns 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Frontside 6 Backside 7 Installation 8 Set Up and Operation 8 Connection modes 9 Stereo connection example 9 Mono connection exam...

Страница 3: ...this manual Before you initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintain perfect conditio...

Страница 4: ...necessary to reduce the input signal level by using the INPUT control To emphasize a frequency range you do not necessarily have to move its respective control upward try lowering surrounding frequenc...

Страница 5: ...r UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your addre...

Страница 6: ...Inputs 2 x XLR inputs 2 x 6 3 mm jack Input impedance 20 KOhm balanced Features S N Rate A weight 95 dB Freq response 3 Hz 40 kHz 0 3 dB THD 0 004 typ 4 dBu 1KHz Crossover freq range 80 Hz 10 kHz Pha...

Страница 7: ...switch Mute button Low gain Channel 1 2 This button will mute the Low frequency band If you mute the Low frequency band you will only hear the High frequency band Low gain Channel 1 2 The Low gain ad...

Страница 8: ...6 dB x oct up to 22 5 kHz Channel 1 output low jack 6 3 mm Balanced stereo 6 3 mm jack output for the Low frequency band in stereo mode In the mono mode this is a mono 6 3 mm jack output for the Low f...

Страница 9: ...ut for the High frequency band Channel 1 output high XLR Balanced stereo XLR output for the High frequency band in stereo mode In the mono mode this is a mono XLR output for the High frequency band IE...

Страница 10: ...ote Switch the ACX 2 in the stereo mode as indicated in the figure above Link all the cables before connecting electric power First plug the ACX 2 into a proper electric power supply then the amplifie...

Страница 11: ...ch the ACX 2 in the mono mode as indicated in the figure above Link all the cables before connecting electric power First plug the ACX 2 into a proper electric power supply then the amplifiers If you...

Страница 12: ...ir life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Balanced...

Страница 13: ...rewdriver into the slot in the fuse cover Gently pry up the fuse cover The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the replacement fuse into the holde...

Страница 14: ...3mm jack Output impedance 300 Ohm balanced Features S N Rate A weight 95 dB Freq response 3 Hz 40 kHz 0 3 dB THD 0 004 typ 4 dBu 1KHz Crossover freq range 80 Hz 10 kHz Phase correct range 0 180 Dynam...

Страница 15: ...14 ACX 2 Ordercode D1905 Dimensions...

Страница 16: ...2016 DAP Audio...

Отзывы: