background image

 

  

 

 

 

 

1U Fan Unit 

Ordercode: D7681 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 
Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 
01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to report and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
agreed otherwise in writing. 
Complaints against us must be prepared in writing or sent by fax within 10 working days after receipt of 
the invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement from which the obligation is resulting.  
 

 

Содержание 1U fan unit

Страница 1: ...1U Fan Unit V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D7681 MANUAL ENGLISH ...

Страница 2: ...Connection with the mains 4 Return Procedure 5 Claims 5 Description of the device 6 Frontside 6 Backside 6 Installation 7 Set Up and Operation 7 Connecting Sensor cable 7 Control panel 7 Set the temperature limit 8 Menu mode 8 Warnings 9 Maintenance 9 Troubleshooting 9 Product Specifications 10 Dimensions 10 ...

Страница 3: ...t includes DAP Audio 1U Fan Unit IEC powercable 1 5m Sensor cable 1 6m Mounting pins User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qualified follow the instructions of this manual Before you initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and d...

Страница 4: ... sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that the core diameter of extension cords and power cords is sufficient for the required power consumption of the device Make sure you do not use the wrong kind of cables or defective cables Never let the power cord come into contact with other cables Handle the power cord and all ...

Страница 5: ...ration may lead to dangers like short circuit burns electric shock etc You endanger your own safety and the safety of others Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN...

Страница 6: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merc...

Страница 7: ...ve humidity 20 85 no condensate Power consumption 60W max Temperature controlling range 0ºC 50ºC Input PTC 10kOhm included Dimensions 483 x 290 x 44 mm LxWxH 19 x 1HE LxH Weight 4 8 kg Frontside Fig 02 Control unit Temperature controller press the control buttons to adjust the maximum temperature and temperature limit For more information see page 8 Power switch ON OFF Press the button to switch t...

Страница 8: ... make sure that the Sensor cable is connected properly Damage caused by connecting the device to improper AC voltage is not covered by any warranty Connecting Sensor cable Connect the included sensor cable to the device The RED cable has to be connected with the RED input The WHITE cable has to be connected with the BLACK input Move the sensor to an appropriate position outside your rack Now the d...

Страница 9: ...rature display status Menu mode 01 Press the Set 8 and Increase 9 buttons simultaneously for 5 seconds until the display shows F0 02 With this option you can set the temperature difference between the temperature limit and the temperature at which the fans shut down 03 Press the Set button 8 again to adjust this temperature 04 Press the Increase 9 and Decrease 11 buttons to set the desired tempera...

Страница 10: ...loth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting DAP Audio 1U Fan Unit This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps 01 If the device does not operate properly unplu...

Страница 11: ... 19 x 1HE LxH Weight 4 8 kg Inputs Outputs Input PTC 10kOhm included Features Resolution 1 ºC Capacity of connective of relay 7A 250V AC Sensor error delay time 1 min Relative humidity 20 85 no condensate Temperature controlling range 0ºC 50ºC Max ambient temperature ta 50 C Design and product specifications are subject to change without prior notice Dimensions Website www Dap audio info Email ser...

Страница 12: ... 2018 DAP Audio ...

Отзывы: