DanVex DEH-900i Скачать руководство пользователя страница 16

R

www.danvex.fi

1

5

Operation

 

Notices

1. When moving the machine, do not incline the machine for over 45°to avoid

damaging the compressor.

2. Temperature for operation of this machine is 5-35

.

3. When it is operating

the compressor gives off heat when it works

and

ambient temperature may rise by 1-3

.Such phenomenon is normal and is safe to use.

4. When ambient temperature is below 10

℃ 

and absolute humidity is relatively

low

there is no need to use dehumidifier.

5. The air inlet and outlet must be away from the wall for at least 10cm in order

not to impair the dehumidification effect.

6. Working  environment  shall  be  as  airproof  as  possible  to  maximize

dehumidification on effect.

7. Dust on the air purification filter mesh may impair its effect or even cause

failure.  Please  clear  regularly  for  at  least  once  a  month.  If  there  is  much  dust  in  the 

environment

it  must  be  cleared  once  a  week  or  once  a  day.  Pull  down  the  front 

panel

clear the filter mesh. Tap the filter mesh slightly or eliminate the dust by vacuum 

cleaner  or  place  the  mesh  in  warm  water

≤40℃  and  add  appropriate  neutral 

scour

and brush and then wash with clear water and dry it. Direct sunlight or baking 

shall be avoided to prevent deformation.

Failure

Cause analysis

Method

Dehumidifier

cannot work

1.Power cut

2.Power switch is not

energized

3.Power cord is not

connected

4.Fuse is melted

1.Recover the power

2.Energize the power

3.Connect the power cord

4.Replace the fuse

Dehumidification is

not ideal

1.Dust accumulated in air

purification filter mesh

2.Object blocking air inlet

and outlet

3.The door or window is

open

4.Refrigerant is leaking

1.Clear the filter mesh

2.Remove

the

blocking

object

3.Close the door and

window

4.Contact with distributor or

manufacturer for repair

Water leak

1.The machine is inclined

2.Water pipe is blocked

1.Level the machine

2.Remove

the

blocking

object

Abnormal noise

1.The machine is not

placed solidly

2.The filter mesh is

blocked

1. Place the machine firmly.

2. Clear the filter mesh.

Common

 

Troubleshooting

Содержание DEH-900i

Страница 1: ...DanVex DEH 900i DanVex DEH 1200i Dehumidifiers Operation manual ...

Страница 2: ...R www danvex fi 1 ...

Страница 3: ...ification principles Attention These units cannot be used for air cooling Use of DanVex dehumidifier Despite of windows and doors insulation quality damp and moisture can penetrate even through thick concrete walls It can take 1 2 months for the water used for construction concrete works whitewashing plasterworks etc to dry out The moisture that has penetrated masonry following high water or flood...

Страница 4: ...outside 2 By the air dehumidification The moist air in an enclosed room is continuously dehumidified by the condensation principle or by other dehumidification method In terms of energy consumption the air dehumidification has one essential advantage the energy expenditure requirements are limited by the air volume in the existing room only The heat generated during the air dehumidification proces...

Страница 5: ...oled the maximum water vapor volume that can be absorbed continuously reduces the water vapor volume contained in the air remains however the same and the relative humidity increases If the air temperature falling continues the capacity to absorb the water vapor volume is continuously reduced until the air becomes saturated which is equal to the maximum water vapor content in the air This temperat...

Страница 6: ... dehumidifier The air flow is cooled on the way through the evaporator condenser system till its temperature is below the dew point Water vapor condenses it is collected in a condensate trap inside the unit The collected moisture is discharged in the form of water 5 Heat of condensation The energy transferred from the condenser to the air consists of The heat earlier transferred from the evaporato...

Страница 7: ...es or in case the unit is not used for the intended purpose The following safety instructions must be observed It is prohibited to install or operate the units in the locations subject to explosion hazard It is prohibited to install or operate the units in the locations with oil sulphur chlorine or salt containing atmospheres The units must be installed upright It is prohibited to use a direct jet...

Страница 8: ...ssure fail safe and long term operation of the unit The unit complies with the fundamental safety and health requirements of the existing EU regulations The unit is easy and safe to operate Dehumidifier operation The fan intakes moist air through air intake grill located at the front of the dehumidifier equipped with an air filter Than the air flows through evaporator and condenser located in the ...

Страница 9: ... to the waste water disposal system should be connected with the connector external part In this case the humidifier can work continuously without interruptions caused by the condensate discharge from the filled tank Unit location The unit is operated in the buildings where dry air is necessary for technological processes people comfort and where it prevents significant financial losses due to goo...

Страница 10: ... 0100 Part 704 for electric current supply sources equipped with automatic circuit breakers If the unit is installed in humid premises such as laundries or cellars it should be equipped with proper automatic circuit breakers at the buyer s expense Dehumidifier design models DanVex DEH 900i and DEH 1200i 9 Electric cable Humidity sensor Transportation handle Cover Hose Condensate tank ...

Страница 11: ...R www danvex fi 10 Grill Air filter Control panel Connector ...

Страница 12: ...creen and click or to adjust the time B In working mode press timer to set Auto stop time off time will flash in screen and click or to adjust the time 3 button Press this button directly to increase the set humidity Buzzer buzzes once for each pressing and the set humidity decreases by 1 RH Successive operation can be achieved by pressing this button successively Press Time button before pressing...

Страница 13: ... time Press the Time button for the first time the hour time on the display flashes press and to adjust the current hour and minute time Press the Time button for the second time the Start up time on the LCD flashes press and to adjust the current hour and minute time Press the Time button for the third time the Stop time on the LCD flashes Press and to adjust the current hour and time Press the T...

Страница 14: ...tore the current status before the power is cut and enter the operation mode before power cut automatically after power is supplied 5 Range for humidity is 20 90 6 If the dehumidifier is going to be spared for a long time please unload the power cord or cut the power 7 Auto detection of temperature humidity failure a When the system detects that temperature sensor exceeds the limited range the sys...

Страница 15: ...hat temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock accidents Please place the machine in firm places If the machine falls down the water in water tank may leak out and damages stuff around and results in creepage and cause fire or electric shock accident...

Страница 16: ...own the front panel clear the filter mesh Tap the filter mesh slightly or eliminate the dust by vacuum cleaner or place the mesh in warm water 40 and add appropriate neutral scour and brush and then wash with clear water and dry it Direct sunlight or baking shall be avoided to prevent deformation Failure Cause analysis Method Dehumidifier cannot work 1 Power cut 2 Power switch is not energized 3 P...

Страница 17: ...acity Internal condensate tank capacity Cooling agent Power Frequency Rated consumption Sound pressure Depth Width Height Gross weight С RH l day m3 hour liters V Hz kW dB A mm mm mm kg DEH 1200i 5 32 40 95 120 1150 14 R407c R22 230 50 1 86 64 514 633 940 57 DEH 900i 5 32 40 95 90 1000 14 R407c R22 230 50 1 47 64 514 633 940 52 Specifications ...

Страница 18: ...R www danvex fi Attachment Electrical diagram 17 ...

Страница 19: ...e equipment normal operation All recommendations and instructions of the manufacturer concerning the equipment installation operation and maintenance were observed Only original parts and materials were used for the equipment maintenance and repair R www danvex fi 18 1 Where the above troubles cannot be fixed and repair is needed please contact supplieror distributor Do not disassemble without aut...

Страница 20: ......

Отзывы: