background image

R

www.danvex.fi

5

It may cause the fire or deformation of the 
housing.

SAFETY PRECAUTIONS

WARNING

 

Do not pull the power cord.

Do not apply an insecticide
or flammable spray.

Prior to the unit cleaning it should be
switched. Disconnect the power cord
from the electric mains.

It can cause the short circuit and lead the 
electric shock or fire.

Do not clean the unit with water.

It may cause the electric shock.

Since the fan rotates at high speed during 
operation, the cleaning of the operating unit 
may cause an injury.

If the unit is installed in the wet place,
provide its insulation against the
moisture ingress.

If the insulation against the 
moisture ingress isn't provided, 
it may cause the electric shock.

 

If not to do it, the dirt may collect in the unit 
and cause the fire.

When the unit is not going to be used for
a long time, disconnect it from the
electric mains.

Do  not

 

install  the  unit  where  there  is 

flammable gas.

Do not install the unit where its operation
is not safe.

Do not operate switches with wet hands.

It may cause the electric shock.

Don't try to install the unit by yourself.

If this is done incorrectly, it may cause the 
fire, electric shock, water leakage, etc.

Contact your local dealer.

Содержание DEH-600wp

Страница 1: ...D EH 600wp DEH 1000wp DEH 1700wp DEH 2000wp DEH 2500wp DEH 4000wp Operation manual Dehumidifiers ...

Страница 2: ...R www danvex fi 1 Please read this manual carefully before using your dehumidifier and keep it well If you have any question of using your dehumidifier please contact your local dealer ...

Страница 3: ...tion 3 Safety precautions 4 Dehumidifier description 6 Electric circuit diagrams 10 Installation instructions 13 Start up and operation 15 Error messages 16 Denumidifier maintenance 18 Technical specifications 19 Warranty obligations 20 ...

Страница 4: ...S DEH 600wp DEH 1000wp DEH 1700wp DEH 2000wp DEH 2500wp DEH 4000wp All the dehumidifiers described in this manual are designed to adjust the indoor relative humidity from 40 RH to 99 RH at the ambient temperature from 1O C up to 32 C 3 ...

Страница 5: ...gers or any objects in the air inlet air outlet Do not repair or reinstall of the unit by yourself If this is done incorrectly it may cause the fire electric shock water leakage etc Contact your local dealer Don t do it under any circumstances Follow the instruction by all means Be sure to ground Disconnect the power cable from the electric mains Never put anything on the unit Danger of electric s...

Страница 6: ... cause an injury If the unit is installed in the wet place provide its insulation against the moisture ingress If the insulation against the moisture ingress isn t provided it may cause the electric shock If not to do it the dirt may collect in the unit and cause the fire When the unit is not going to be used for a long time disconnect it from the electric mains Do not install the unit where there...

Страница 7: ...R www danvex fi 6 Dehumidifiers DEH 600wp and DEH 1000wp DEHUMIDIFIER DESCRIPTION Power cord Air outlet Control panel RIGHT SIDE FRONT SIDE Air inlet Drain hose LEFT SIDE Base ...

Страница 8: ...R www danvex fi 7 Dehumidifiers DEH 1700wp и DEH 2000wp DEHUMIDIFIER DESCRIPTION Power cord Air outlet RIGHT SIDE FRONT SIDE Air inlet Drain hose LEFT SIDE Base Control panel ...

Страница 9: ...R www danvex fi 8 Dehumidifiers DEH 2500wp и DEH 4000wp DEHUMIDIFIER DESCRIPTION Power cord Air outlet RIGHT SIDE FRONT SIDE Air inlet Drain hose LEFT SIDE Base Control panel ...

Страница 10: ...set 2 Anchor bolt 6 pcs per humidifier set used for unit wall mounting 3 Mounting screw 4 pcs per humidifier set used for unit wall mounting 4 Floor foot 4 pcs per humidifier set used for unit floor mounting 5 Wheel 4 pc per humidifier set used for unit mobile mounting 6 Drain hose 1 pc per humidifier set ...

Страница 11: ...le phase 1PH 5o Hz ELECTRIC CIRCUIT DIAGRAMS Humidity sensor Internal temperature sensor External temperature sensor To display PCB Transformer Main controller PCB Fan motor Compressor Power supply High pressure protection Low pressure protection ...

Страница 12: ...H 50 Hz ELECTRIC CIRCUIT DIAGRAMS Humidity sensor Internal temperature sensor External temperature sensor To display PCB Transformer Main controller PCB Fan motor Compressor Power supply High pressure protection Low pressure protection Pressure control valve ...

Страница 13: ...T DIAGRAMS Humidity sensor Internal temperature sensor Transformer Main controller PCB Fan motor Compressor Pressure control valve External temperature sensor To display PCB Low pressure protection High pressure protection Red Black White Gray Green PCB protection phases sequence ...

Страница 14: ...e Step 2 Install the floor feet in the base holes Step 3 Move the dehumidifier to the necessary place Step 4 Adjust the feet height as required Step 5 Connect the drain hose to the dehumidifier Switch the dehumidifier on for the trial operation Check whether there is any abnormal vibration and noise Step 6 Installation is finished and the dehumidifier is ready for the use WHEELS INSTALLATION ...

Страница 15: ...with the hammer Step 3 Install the wall bracket with the anchor bolts on the right position Please take care to fix the bracket well with the nuts and gaskets And don t forget to keep the bracket in the right direction during the installation Step 4 Mount the dehumidifier on the wall bracket and locate it in such a way that the holes in the dehumidifier base are aligned with the bracket holes Fix ...

Страница 16: ... the button when the display shows it will be shown RH that means the nonstop dehumidification 4 Button is used to turn the electric heater option on and off STARTUP AND OPERATION REMOTE CONTROL UNIT FUNCTIONS OF THE CONTROL PANEL AND REMOTE CONTROL UNIT ATTENTION Please study the control functions carefully or make the necessary adjustments prior to the dehumidifier operation CONTROL PANEL ON OFF...

Страница 17: ...al temperature sensor is not working correctly Please contact your dealer E3 Ambient temperature is over the working temperature If the ambient temperature is over 32 C or below 10 C it will display error message E3 too Please contact your dealer E4 The defrosting temperature sensor is not working correctly Please contact your dealer IF THE HUMIDIFIED STOPS WORKING THE DIPLAY WILL SHOW THE ERROR M...

Страница 18: ...ning process and indicates that the current is exceeded or the phase is lacking Clean the evaporator and condenser Please contact your dealer E6 Indicates the low pressure level Please contact your dealer E7 Indicates the high pressure level Please contact your dealer E8 The refrigerant level is insufficient Please contact your dealer IF THE HUMIDIFIED STOPS WORKING THE DIPLAY WILL SHOW THE ERROR ...

Страница 19: ...he socket Ensure that the air inlet and air outlet are not blocked Ensure that the grounding wire is connected properly WARNING Switch the dehumidifier off or disconnect the plug from the socket if you are not going to use it fro a long time Dirt can be accumulated and cause the fire WARNING Use the ground Prevent the contact of the grounding wire with a gas pipe water pipe lightning rod or teleph...

Страница 20: ... indicated directly on the nameplate it s necessary to use the specifications of the nameplate o 3 Test data ambient temperature is 30 C and the ambient humidity is 80 RH SPECIAL INSTRUCTIONS 1 Customer should contact the special service department for the qualified installation and repair 2 If any flexible cable is damaged contact the special service department to replace it with the original cab...

Страница 21: ...lies the Customer a repaired or a spare part Parts repair or replacement does not result in the warranty period extension The parts and components replaced under the warranty belong to DanVex DanVex or its distributor upon DanVex request has a right to inspect the defective parts and to check the correctness of the warranty claim Warranty repair execution conditions The damage occurred during the ...