A.General parameters

6.1.4  

Parameters

 

Setting

Filter max. working 

time alarm,

disappear after reset

Current humidity

%

Current air speed,AC 3 

speeds,EC 1~5 speed.

WIFI connection

established

WIFI connection not

established

ESP32 trigger

Defrost

Compressor relay 

output active

- Compressor working

- Flashing when the 

minimum absolute 

humidity protection

 is activated

Humidification

Timer

H05=1,temperature in 

degrees Fahrenheit

F

H05=0,

temperature in 

degrees Celsius

C

100% fresh air

Dehumidification mode

Cooling mode

Heating mode

Mixed fresh and

return air

100% return air

6.1.5  Icon:

19

20

Air Damper

Factory parameters setting:

Only for the available system working mode.

Filter

:

Short press 

 

 to set the available code;

Long p

ress

 

 

 for 5 seconds to enter the factory parameters setting mode:the parameters code 

R,P,O,H,C,A,D,F will appear;

Factory parameters setting:

Mode 

C

hange

:

Long p

ress

 

 

 for 5 seconds to enter the factory parameters setting mode:the parameters code 

R,P,O,H,C,A,D,F will appear;

Press 

 

 or 

 

 

 

to select the parameters code R,P,O,H,C,A,D,F;

Press

 

 

 to reduce humidity, press 

 

 to raise humidity (1% changed each press)

.

Long p

ress

 

Short

 

press

 

 

 & 

 

 simultaneously for 5 seconds 

to display the run time,wait for 5 seconds to 

exit

;

Short press 

 

 to set the available code;

Press

 

 

 to open or close the air damper.

Short press 

 

 & 

 

 simultaneously to change the available system working mode.The temperature in the 

top will flash,p

ress 

 

 to reduce 

temperature

, press 

 

 to raise 

temperature

 (

0.5°C

 changed each press)

.

Short press 

 

 to exit without saving during the code value setting or return to the previous page;

Long press 

 

 & 

 

 & 

 

 simultaneously for 3 seconds to reboot the controller

s setting;

Humidity Set

:

ON/OFF:

Short press 

 

 & 

 

 simultaneously to change the available system working mode.

Press

 

 

 or 

 

 t

o select the parameters code R,P,O,H,C,A,D,F;

5 seconds without setting,the value will be saved and exit 

Short press 

 

 to save the code value;

Press 

 

 to

 

adjust the fan speed.

Short pressto 

 

 

to exit during parameters setting. 

Fan 

S

peed

:

Long p

ress

 

 

 

for 10 seconds to clear the alarm and reset the time

.

Short pressto 

 

 turn on/off the controller:the small OFF appear in the top when the unit is powered off 

and disappear after 3 minut

;

es

B.Factory Parameters

Press 

 

 or 

 

 

to adjust the code value;

10 seconds without setting,the value will not be saved and exit to the home screen. 

Содержание DEH-3K

Страница 1: ...g Dehumidi ers Any questions please contact the manufacturer or dealer in time The repair and maintenance must be conducted by certi fed professionals Please read the manual carefully and in full befo...

Страница 2: ...ates actions that must be prohibited If not strictly followed it may cause serious damage to the machine or personal injury or death When a problem occurs such as a burning smell etc please turn off t...

Страница 3: ...eck 5 2 2 Wiring Check 5 2 3 Controller Check 6 Controller 6 1 General 6 1 1 Controller Terminals 6 1 2 Terminals Diagram 6 1 3 Controller s Interface 6 1 4 Parameters Setting 6 1 5 Icon 6 2 Controlle...

Страница 4: ...peration of the compressor discharge high temperature and high pressure gas from the exhaust port enter the condenser for cooling It becomes a low temperature and high pressure gas intercepted by a ca...

Страница 5: ...e of the equipment can be easily carried out The unique defrosting device effectively guarantees the reliable operation of the dehumidifier The fan adopts a centrifugal external rotor fan steel volute...

Страница 6: ...ane fins the heat exchange efficiency is increased by 20 thus to reduce the unit size and weight The high quality thermal insulation material increases the thermal insulation effect by 15 2 5 5 Thrott...

Страница 7: ...t in humidity temp sensor I IPX3 55DB 60DB 65DB Mitsubishi R410A copper tubes with blue hydrophilic coated aluminum fins SUS304 25 32 32 G4 PRE Filter 1122 600 1850mm DEH 5K DEH 10K 11KW 22KW 20A 40A...

Страница 8: ...led indoors During installation there should be maintenance space at the rear of the dehumidification equipment to facilitate future inspection and maintenance of the equipment For cleaning and mainte...

Страница 9: ...alled at a position 1 meter to 1 5 meters above the ground in order to detect representative water in the controlled area Flat or laid at the inspection point according to the design requirements The...

Страница 10: ...tdoors to extract air as fresh air and then sent to a separate space after dehumidification such as paint spray room purification room 4 1 2 Ducting for Fresh Air Dry air Wet air Wet fresh air Dry fre...

Страница 11: ...idifier unit must be carried out by professional staff Otherwise the company will not be responsible for all the consequences caused Check the installed air filter device to ensure it is in a clean st...

Страница 12: ...um fan speed Fan coil valve Low fan speed Humidifier Compressor Air damper open Air damper close EC motor supply fan EC motor exhaust fan 12VDC RS485 A1 RS485 B1 RS485 A2 RS485 B2 GND FAN 1 FAN 2 L N...

Страница 13: ...umidity press to raise humidity 1 changed each press Long press Short press simultaneously for 5 seconds to display the run time wait for 5 seconds to exit Short press to set the available code Press...

Страница 14: ...es later after achieved the set humidity and temperature only for the available system working mode F01 2 high fan speed low fan speed available High fan speed low fan speed available when H04 1 F01 3...

Страница 15: ...rror code is E01 It will resume operation after the error addressed The error code is E03 It will resume operation after the error addressed if there is RS485 1 communication failure only the fan keep...

Страница 16: ...unction Code Byte Read Only or Read Write Object Read Write 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes 2 bytes Read Write R...

Страница 17: ...e to download Smartlife App 4 Open APP and select Add device 5 Slide to Auto Scan 6 Press and hold on off button for 10 seconds until LCD full display Then release the button 7 APP will discover the d...

Страница 18: ...r it is working normally and callibrate correctly 3 6 months 12 months 8 2 Troubleshooting procedures 8 1 Troubleshooting Introduction The purpose of this chapter is to help the operator of the unit t...

Страница 19: ...C 13 14 t s 9 5 04 8 3 KT1 KT2 04 8 4 H3Y 2 C 360S 9 5 B3 KM3 A1 A2 KT2 360S H3Y 2 C 13 14 t s 9 5 04 9 3 KT2 1 T1 04 3 1 2 T2 04 3 1 3 T3 04 3 1 KM3 KT3 04 9 4 H3Y 2 C 540S 9 5 B4 KM4 A1 A2 KT3 540S...

Отзывы: