For water this is 2250kJ/kg (4.18kJ = 1kcal)

This shows that a relatively large amount of energy is released in the process of water vapor 
condensation.
If the moisture to be condensed is not generated at evaporation in the room but is introduced 
from outside, e.g. via ventilation, the heat of condensation released in the process will be 
used for the room heating. 
If it is required to dry materials or rooms the heat energy circulates, i.e. it is consumed during 
evaporation and is released during condensation. A large amount of heat energy is generated 
at the supplied air dehumidification process, which results in a rise of temperature.
The time necessary for drying of building structures does not depend on the dehumidifying 
unit capacity, but is determined by the rate at which the material or the building elements 
release the moisture they contain. 

Safety Instructions

Prior to delivery the units are subject to comprehensive testing of their materials, functional 
capabilities and quality.
However hazards can arise if the unit is operated by untrained persons unfamiliar with its 
operation principles or in case the unit is not used for the intended purpose.

 The following safety instructions must be observed:

·

It is prohibited to install or operate the units in the locations subject to explosion
hazard.

·

It is prohibited to install or operate the units in the locations with oil, sulphur, chlorine or
salt containing atmospheres.

·

The units must be installed upright.

·

It is prohibited to use a direct jet of water for the unit washing.

·

It is prohibited to cover the air inlet and outlet holes.

·

The intake side of the unit must be free of dirt and loose objects.

·

It is prohibited to insert objects in the unit.

·

It is prohibited to cover or transport the unit during operation.

·

All electric cables outside the unit must be protected against damage (e.g. from
animals etc.).

·

It is necessary to insure that all cables meet the requirements for capacity, length and
purpose.

·

The unit must only be transported in vertical condition. The condensate containers
must be drained prior to each transportation of the unit.

·

It is prohibited to use the unit for purposes other than intended or not specified in this
operations instructions.

In case the requirements are not observed our company disclaims any liability and out 
warranty becomes null and void. 

Only   authorized    personnel is   permitted to perform works on cooling and  

electrical system! 

Содержание DEH-1600i

Страница 1: ...DanVex DEH 1600i DanVex DEH 1900i Dehumidifiers Operation manual...

Страница 2: ...R www danvex fi 1...

Страница 3: ...fication principles Attention These units cannot be used for air cooling Use of DanVex dehumidifier Despite of windows and doors insulation quality damp and moisture can penetrate even through thick c...

Страница 4: ...utside 2 By the air dehumidification The moist air in an enclosed room is continuously dehumidified by the condensation principle or by other dehumidification method In terms of energy consumption the...

Страница 5: ...led the maximum water vapor volume that can be absorbed continuously reduces the water vapor volume contained in the air remains however the same and the relative humidity increases If the air tempera...

Страница 6: ...dehumidifier The air flow is cooled on the way through the evaporator condenser system till its temperature is below the dew point Water vapor condenses it is collected in a condensate trap inside the...

Страница 7: ...s or in case the unit is not used for the intended purpose The following safety instructions must be observed It is prohibited to install or operate the units in the locations subject to explosion haz...

Страница 8: ...h requirements of the existing EU regulations The unit is easy and safe to operate Unit location The unit is operated in the buildings where dry air is necessary to prevent significant financial losse...

Страница 9: ...nd from outside Windows and doors must be closed to prevent free air exchange between the room and ambient atmosphere If the unit is used in dust laden environments it is necessary to take appropriate...

Страница 10: ...R www danvex fi 9 Explode drawing...

Страница 11: ...standby mode press timer to set Auto starting time on time will flash in screen and click or to adjust the time B In working mode press timer to set Auto stop time off time will flash in screen and cl...

Страница 12: ...it is in operation it will operate the mode of preset stop time We do not ensure the efficient operation of the unit if the room temperature is below 10 C and if the relative humidity is below 40 Oper...

Страница 13: ...ore the current status before the power is cut and enter the operation mode before power cut automatically after power is supplied 5 Range for humidity is 20 90 6 If the dehumidifier is going to be sp...

Страница 14: ...at temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock acci...

Страница 15: ...ed solidly 2 The filter mesh is blocked 1 Place the machine firmly 2 Clear the filter mesh Common Troubleshooting 1 Where the above troubles cannot be fixed and repair is needed please contact supplie...

Страница 16: ...R www danvex fi Attachment Electrical diagram 15...

Страница 17: ...DanVex request has a right to inspect the defective parts and to check the correctness of the warranty claim Warranty repair execution conditions The damage occurred during the equipment normal operat...

Страница 18: ......

Отзывы: