background image

                                                                                                                                                                                   

 

Scrapping 

报废

报废

报废

报废

 

 

Page 24 of 26 

 

9. Scrapping 

报废

 

Introduction 

介绍

 

The air conditioner is designed to last for a number of years. When the time 

comes that the unit needs to be scrapped the following precautions should be 

taken to protect our environment. 

空调的寿命能持续若干年,当机器到了报废的时候,要注意以下几点以保护我们的环

境。

 

 

Please note that the guidelines are general – local rules and procedures may 

overrule these guidelines and should be observed and followed carefully. 

 

请注意总的指导方针是遵循当地的法规

 

和程序。

 

Main 

components 

主要部件

 

The main components of the unit are: 

 

The cooling circuit including the compressor, coils and refrigerant liquid. 

 

The printed circuit boards (PCB’s) with electronic components and con-

necting wires 

 

Fans 

 

Metal parts such as shell. 

主要部件有:

 

 

制冷循环包括压缩机、芯和制冷剂。

 

 

具有电子部件的主板和电线

 

 

风扇

 

 

钣金等等。

 

 

Cooling circuit

制冷循环

制冷循环

制冷循环

制冷循环

 

Refrigerant 

gas 

制冷气体

 

When scrapping an air conditioner the refrigerant needs to be removed from the 

unit even though the air conditioner is using a environmental friendly type of 

refrigerant gas named R134a. 

 

空调报废时需要将制冷剂从机器中移除去,即使空调使用等是环保型制冷剂

R134a

 

 

Only a certified cooling technician should carry out the evacuation by using the 

necessary evacuation and recycling equipment. If the refrigerant gas is not to be 

recycled by the evacuator it must be passed on to the local authorities for de-

composition. 

只有有鉴定资格的技术员才能使用必要的撤除和回收设备撤除。如果制冷气体不用撤除器回
收,必须经当局许可才分解。

 

Compressor 

压缩机

 

The compressor contains oil and precautions must be taken to prevent the oil 

from polluting our environment. The compressor should together with the copper 

Содержание SSC-01

Страница 1: ...elt Suzhou Jiangsu China P Ph ho on ne e 8 86 6 5 51 12 2 6 66 66 67 78 85 50 00 0 F Fa ax x 8 86 6 5 51 12 2 6 66 66 67 78 85 50 01 1 H Ho om me ep pa ag ge e h ht tt tp p w ww ww w d da an nt th he...

Страница 2: ...Introduction Page 2 of 26 Revision information The service manual is first issued Version A issue date 2007 8 A 2007 8 By Alan liu Project Engineer...

Страница 3: ...any condition and should be installed and placed according to the instructions in this manual SSC 01 Storage During storage and transportation the unit must be kept in an upright position Copyright Th...

Страница 4: ...Introduction Page 4 of 26 Michael Norgreen General Manager Dantherm Air handling Suzhou Co Ltd...

Страница 5: ...12 HEATER OPERATION 12 INTERNAL FAN OPERATION 12 5 FUNCTIONALITY TESTING 13 6 TECHNICAL DATA 14 PERFORMANCE AMBIENT RETURN 35 C 35 C 35 C 35 C 14 CABINET DATA 15 ELECTRICAL DATA ERROR BOOKMARK NOT DEF...

Страница 6: ...nts in the package The SSC 01 is delivered with an installation kit with the following content SSC 01 Quantity Unit Item description 1 Pcs SSC 01 1 1 Pcs Pcs Service manual Rejection sheet metal Tools...

Страница 7: ...main power cable from power supply Make sure that the power supply is powered off 2 Demount all screws on the flanges 1 2 3 Identification of the Unit All units have a silver type plate label where a...

Страница 8: ...ontrol board are Compressor Evaporator and condenser fan Heater element Inverter The controller manages the internal temperature based on the return air tem perature Temperature The following terms fo...

Страница 9: ...Standard settings Range Unit Description Function 28 17 30 C Compressor If the return air exceeds set point the compressor starts If the return air drops to 17 C the compressor stops 17 C 7 5 14 C Hea...

Страница 10: ...Description of functionality Page 10 of 26 Failure signal The following alarms will result in failure output Air conditioner malfunction Alarm items are attached in appendix1 1...

Страница 11: ...70 Condenser Fan starts on step II 2 Cond 60 60 High temperature alarm Return 50 45 40 Compressor starts mini mum 3 min 3 Condenser fan starts on step I 1 Return 28 30 22 17 Return Compressor stops Co...

Страница 12: ...C It will switch to low speed again when the temperature is decreased to 57 C 60 C 57 C If the return air temperature decreases to 17 C the compressor will stop even though it has been running less th...

Страница 13: ...ted by pressing the test button on the controller for three seconds Steps Component How to do 1 Press test button in for 3 sec 3 2 Heater Check heater voltage on controller or feel heat in air inlet 3...

Страница 14: ...ominal volt age 48VDC 48VDC 900 Refrigerant g R134a 1000 Flow Internal M3 h Return temperature 520 External M3 h Ambient temperature 800 Pressure Operation Pa Operating pressure 101 3 70 106 Disp Pa E...

Страница 15: ...ication Unit Designation Value Dimensions mm Height x Width x Depth 1229 x 510 x 249 5 Weight kg Total 56 Metal sheet material mm Aluzinc stainless steel 1 0 2 0 Packaging Customer requirement Pallet...

Страница 16: ...mpressed air Carefully clean the unit Soft bristle brush Remove dirt that the vacuum cleaner or compressed air could not remove Screwdriver and bits Tighten loose screws Like a car the units need to b...

Страница 17: ...en performing a preventive maintenance visit is Step Action 1 Make sure that the power to the unit is safely switched off 2 Clean the unit carefully for dust especially at Air ducts Fans Con denser an...

Страница 18: ...ee of obstructions cracks missing blades and in balance Do the fans rotate freely and are they free from excessive vi bration or noise Is all wiring and insulation undamaged Are all connectors seated...

Страница 19: ...passed on when or dering This information can be found on the silver type plate on the cabinet Replacing the internal fan see below pictures Step Action 1 Power off A C and Uninstall A C from the cab...

Страница 20: ...ow pictures Step Action 1 Power off A C and Uninstall A C from the cabinet 2 Remove screws on the cover and thereby unplug the cable connec tor see step1 1 3 Pull out the external fan assembly remove...

Страница 21: ...Replacement of spare parts Page 21 of 26 cover screws for fixing external fan holder Step1 Step2 Replacing the control board see below pictures...

Страница 22: ...oard pins stepI 1 3 Unscrew the 4 machine screws on the controller supporter and pull it out Unscrew the 4 machine screws M3 fixing the control board Pay attention to the screws and nylon distance was...

Страница 23: ...he following steps should be followed Step Action 1 Remove screws on the service cap and remove it from the unit 2 Remove two nuts on the heater bracket which fix the heater and thereby unplug the cab...

Страница 24: ...ds PCB s with electronic components and con necting wires Fans Metal parts such as shell Cooling circuit Refrigerant gas When scrapping an air conditioner the refrigerant needs to be removed from the...

Страница 25: ...tal parts from the wires and PCB s before scrapping PCB PCB Fans The fans consist of plastic metal and an internal PCB They are subject to recy cling and should be left to the local scrap dealer PCB M...

Страница 26: ...in after 5 minutes delay 10 DLT Sensor Failure O O O B ON 11 High Discharge Line Temperature Issue O O O F Air conditioner will shut down and lock after DLT overheat failure 6 times within one hour ON...