52
INSTALLATION & SERVICE MANUAL FOR PROFESSIONALS
Appendix
: Technical data
Appendix
Technical data
Specification
Abbr .
Unit
RCV 320 P2
Max. flow at 100Pa
V
100Pa
m3/h
320
Max. rated flow at 100Pa
V
max.nom
m3/h
200
Operating range DIBt
V
DIBt
m3/h
70-225
Operating range Passivhaus at 100Pa
V
PHI
m3/h
70-160
EN 13141-7 reference flow at 50Pa
V
ref
m3/h
140
Performance
Thermal efficiency in accordance with
EN13141-7
h
SUP
%
89
Leakage (external and internal) in accordance
with EN 13141-7
L
W
(A)
dB(A)
<2% (Class A1)
Filters in accordance with ISO16890
class
-
ISO Coarse 75% (optional
on supply: ePM1>50% )
Filters in accordance with EN779:2012
-
-
G4
(optional on supply: F7)
Installation surrounding temperature
t
SURR
°C
+12 to +45
Outdoor temperature without preheater
installed
t
ODA
°C
-12* to +40
Outdoor temperature with preheater installed
t
ODA
°C
-20 to +40
Maximum absolute humidity of extract air
x
g/kg
10
Cabinet:
Dimensions (with wall bracket)
w x h x d
mm
600 x 603 x 548
Spigots/ducts connections
Ø
mm
ø125 - female
Weight
kg
32
Thermal conductivity - polystyrene insulation
l
W/(mK)
0.031
Heat transition figures- polystyrene insulation
U
W/(m
2
K)
U<1
Fire classification of the polystyrene insulation
-
-
DIN 4102-1 class B2
EN13501 class E
Drainage hose included
Ø/length
“-m
ø3/4” – 1 m
Cabinet colour
RAL
-
no paint/ galvanized steel
Electrical
Voltage
U
V
230
Max. power consumption
(without/ with preheater)
P
W
170/1070
Frequency
f
Hz
50
Protection class
-
-
IP21
* The use of preheating coil is recommended when outdoor temperature is below -3°C to
ensure balanced operation.
Data sheet
RCV 320 P2 Basic
Содержание RCV 320 P2 Basic
Страница 1: ...RCV 320 P2 Basic MANUAL en Rev 1 0 2021 W50 2...
Страница 2: ......
Страница 55: ......