![Dantherm calorex AW834 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/dantherm/calorex-aw834/calorex-aw834_owners-and-installation-manual_3496239023.webp)
470450
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CCT BREAKER MANUALLY SWITCHED TO
THE ON CONDITION.
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED.
WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY.
ELECTRICAL CIRCUIT DIAGRAM
AW3034EHY(F) THREE PHASE (230V ~3 60Hz)
SMAR
T CL
OCK
FEED TERMINALS
FAN
COMPRES
SOR
T1
T2
T3
HEATER
FA
UL
T
LIGHT
INTERLOCK
TERMINALS
OR FL
O
W
ST
AR
TER
SWITCH
INTERLOCK
TERMINALS
COMP A
UX
NC
CONT
A
CT
ORS
CIRCUIT BREAKER
CIRCUIT BREAKER
FAN MCB
ALARM CONT
A
CT
COMPRES
SOR MCB
A
UX CONT
A
CT
CONTROL
CIRCUIT BREAKER
PHA
SE
RO
TA
TION
RELA
Y
RELA
Y 3
DELA
Y
TIMER 1
12 HOUR
POOL
STAT
ST
ANDB
Y
SWITCH
RUN
ST
ANDB
Y
PRO
TECT
OR
MO
TOR
COMPRES
SOR
COMP A
UX
REVERSING
VAL
VE
DEFROST
LIGHT
NO
SHUT OFF
SOL V
AL
VE
MAINS
LIGHT
L3
L2
L1
LP S
WITCH
(BREAKS T
O 'H' ON
PRES
SURE F
ALLING)
HP S
WITCH
(BREAKS T
O 'L
' ON
PRES
SURE RISING)
(N/C)
(N/C)
DEFROST
STAT
MAKES 1 T
O 3 ON TEMP
FALLING
SOFT ST
AR
T
THERMAL
O/L
O
AD AND
FA
UL
T LIGHT
IF FITTED
L
N
6
7
L3
L2
L1
11
14
11
14
A1
A2
A1
A2
15
18
1
2
1
2
95
43
96
44
53
54
21
22
L
H
C
(N/O)
(N/C)
(COM)
L
H
C
(N/C)
(N/O)
(COM)
12
(N/O)
(N/C)
(COM)
(N/O)
(N/O)
(N/O)
(N/O)
(N/O)
(N/O)
5
3
1
6
4
2
6
4
2
5
3
1
(N/C)
(N/C)
(N/C)
5
3
1
6
4
2
(N/C)
(N/C)
(N/C)
5
3
1
6
4
2
(N/C)
(N/C)
(N/C)
5
3
1
6
4
2
(N/O)
(COM)
(N/O)
(COM)
3 (N/C)
A2
A1
A1
A2
2
(N)
1
(COM)
3
(NO)
4
(NC)
(COM)
(NO)
16
A1
A2
18
15
(COM)
(N/C)
(N/O)
4
7
RELA
Y 2
1
(COM)
(N/C)
(N/O)
1
9
7
RELA
Y 1
4
6
3
(COM)
(COM)
(N/C)
(N/C)
(N/O)
(N/O)
B
A
B
A
(NO)
63
64
COMP A
UX
6 MINS DELA
Y TIMER 2
CIRCUIT BREAKER SETTING
COMPRESSOR
FAN
27.3A
5.3A
MODELS
AW3034EHY(F)
CONTROL
2.0A
470150
ELECTRICAL CIRCUIT DIAGRAM
AW3034EH(F) THREE PHASE (230V ~3 60Hz)
CIRCUIT BREAKER SETTING
COMPRESSOR
FAN
CONTROL
MODELS
27.3A
5.3A
2.0A
AW3034EH(F)
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CCT BREAKER MANUALLY SWITCHED TO
THE ON CONDITION.
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED.
WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY.
SMAR
T CL
OCK
FEED TERMINALS
L
N
7
8
FAN
COMPRES
SOR
L1
L2
L3
HEATER
L3
L2
L1
INTERLOCK
TERMINALS
OR FL
O
W
ST
AR
TER
SWITCH
INTERLOCK
TERMINALS
SOFT ST
AR
T
COMP A
UX
N/C
A
UX
SHUT OFF
SOL VALVE
N/O
THERMAL
O/L
O
AD AND
FA
UL
T LIGHT
IF FITTED
CONT
A
CT
ORS
CIRCUIT BREAKER
CIRCUIT BREAKER
FAN MCB
ALARM CONT
A
CT
COMPRES
SOR MCB
A
UX CONT
A
CT
CONTROL
CIRCUIT BREAKER
PHA
SE
RO
TA
TION
RELA
Y
L1
L2
L3
11
RELA
Y 3
11
14
A1
A2
A1
A2
15
18
95
43
96
44
14
FA
U
LT
DEFROST
STAT
POOL
STAT
ST
ANDB
Y
RUN
ST
ANDB
Y
1
2
SWITCH
LIGHT
C
L
(N/O) 1
2 (COM)
54
53
21
22
12 HOUR
DELA
Y TIMER 1
PRO
TECT
OR
MO
TOR
COMPRES
SOR
LP S
WITCH
(BREAKS T
O 'H' ON
PRES
SURE F
ALLING)
HP S
WITCH
(BREAKS T
O 'L
' ON
PRES
SURE RISING)
L
H
C
(N/O)
(N/C)
(COM)
L
H
C
(N/C)
(N/O)
(COM)
(N/O)
(N/O)
(N/O)
(N/O)
(N/O)
(N/O)
5
3
1
5
3
1
2
4
6
6
4
2
12
(N/O)
(N/C)
(COM)
(N/C)
(N/C)
(N/O)
(COM)
(N/C)
(N/C)
(N/C)
5
3
1
6
4
2
(N/C)
(N/C)
(N/C)
5
3
1
6
4
2
(N/C)
(N/C)
(N/C)
5
3
1
6
4
2
A1
A1
A2
A2
N/C
3 (N/C)
(COM)
(N/O)
MAINS
LIGHT
16
A1
A2
18
15
6
MINS
(COM)
(N/C)
(N/O)
4
7
RELA
Y 2
1
(COM)
(N/C)
(N/O)
1
9
7
RELA
Y 1
4
6
3
(COM)
(COM)
(N/C)
(N/C)
(N/O)
(N/O)
B
A
B
A
(NO)
63
64
COMP A
UX
6 MINS DELA
Y TIMER 2
H
(N/O)
DEFROST LIGHT
23
SD331851 ISSUE 28