ELECTRICAL CIRCUIT DIAGRAM
AW3034BHY(F) THREE PHASE (400V ~3 N 50Hz)
CIRCUIT BREAKER
DRG No. P420658
ELECTRICAL CIRCUIT DIAGRAM
AW3034BH(F) THREE PHASE (400V ~3 N 50Hz)
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CCT BREAKER MANUALLY SWITCHED TO THE ON CONDITION.
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED.
WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY.
CIRCUIT BREAKER SETTING
COMPRESSOR
FAN
19.8A
3.5A
2.0A
19.8A
3.5A
2.0A
CONTROL
AW3034BH(F)
SMAR
T CL
OCK
FEED TERMINALS
L
N
8
9
FAN
COMPRES
SOR
L1
L2
L3
HEATER
MAINS LIGHT
L3
L2
L1
NEUTRAL
INTERLOCK
TERMINALS
OR FL
O
W
ST
AR
TER
SWITCH
INTERLOCK
TERMINALS
SOFT ST
AR
T
COMP A
UX
N/C
A
UX
SHUT OFF
SOL VALVE
N/O
THERMAL
O/L
O
AD AND
FA
UL
T LIGHT
IF FITTED
CONT
A
CT
ORS
CIRCUIT
BREAKER
CIRCUIT
BREAKER
FAN MCB
ALARM CONT
A
CT
COMPRES
SOR MCB
ALARM CONT
A
CT
CONTROL
CIRCUIT
BREAKER
L3
L2
L1
PHA
SE
RO
TA
TION
RELA
Y
11
14
RELA
Y 3
11
14
A1
A2
A1
A2
15
18
FA
U
LT
POOL
STAT
ST
ANDB
Y
RUN
ST
ANDB
Y
1
2
SWITCH
LIGHT
95
95
96
96
54
53
21
22
(N/O) 1
(COM) 2
12 HOUR
DELA
Y TIMER 1
PRO
TECT
OR
MO
TOR
COMPRES
SOR
12
(N/O)
(N/C)
(COM)
LP S
WITCH
(BREAKS T
O 'H' ON
PRES
SURE F
ALLING)
HP S
WITCH
(BREAKS T
O 'L
' ON
PRES
SURE RISING)
L
H
C
(N/O)
(N/C)
(COM)
L
H
C
(N/C)
(N/O)
(COM)
(N/O)
(N/O)
(N/O)
(N/O)
(N/O)
(N/O)
5
3
1
5
3
1
2
4
6
2
4
6
(N/C)
(N/C)
(N/C)
(N/C)
(N/C)
5
3
1
2
4
6
(N/C)
(N/C)
(N/C)
5
3
1
2
4
6
(N/C)
(N/C)
(N/C)
5
3
1
2
4
6
(N/O)
(COM)
3 (N/C)
A1
A1
A2
A2
(N/O)
(COM)
16
A1
A2
18
15
6
MINS
(COM)
(N/C)
(N/O)
4
7
RELA
Y 2
1
(COM)
(N/C)
(N/O)
1
9
7
RELA
Y 1
4
6
3
(COM)
(COM)
(N/C)
(N/C)
(N/O)
(N/O)
B
A
B
A
(N/O)
63
64
COMP A
UX
6 MINS
DELA
Y TIMER 2
DEFROST
STAT
C
L
N/C
H
(N/O)
DEFROST LIGHT
FEED TERMINALS
L
N
9
10
FAN
COMPRES
SOR
T1
T2
T3
HEATER
FA
UL
T
LIGHT
L3
L2
L1
INTERLOCK
TERMINALS
OR FL
O
W
ST
AR
TER
SWITCH
INTERLOCK
TERMINALS
SOFT ST
AR
T
COMP A
UX
N/C
THERMAL
O/L
O
AD AND
FA
UL
T LIGHT
IF FITTED
CONT
A
CT
ORS
CIRCUIT BREAKER
CIRCUIT BREAKER
FAN MCB
ALARM
CONT
A
CT
COMPRES
SOR MCB
ALARM CONT
A
CT
CONTROL
CIRCUIT
BREAKER
MAINS LIGHT
NEUTRAL
L3
L2
L1
PHA
SE
RO
TA
TION
RELA
Y
11
14
RELA
Y 3
11
14
A1
A2
A1
A2
15
18
12 HOUR
DELA
Y TIMER 1
POOL
STAT
ST
ANDB
Y S
WITCH
RUN
ST
ANDB
Y
1
2
NO
1
COM
2
21
22
53
54
COMP A
UX
REVERSING
VAL
VE
DEFROST
LIGHT
N/O
SHUT OFF
SOL V
AL
VE
95
95
96
96
PRO
TECT
OR
MO
TOR
COMPRES
SOR
12
(COM)
(N/O)
(N/C)
(N/O)
(N/O)
(N/O)
(N/O)
(N/O)
(N/O)
5
3
1
5
3
1
2
4
6
2
4
6
LP S
WITCH
(BREAKS T
O 'H' ON
PRES
SURE F
ALLING)
HP S
WITCH
(BREAKS T
O 'L
' ON
PRES
SURE RISING)
L
H
C
(N/O)
(N/C)
(COM)
L
H
C
(N/C)
(N/O)
(COM)
(N/C)
(N/C)
(N/O)
(N/C)
(N/C)
(N/C)
(N/C)
(N/C)
(N/C)
(N/C)
(N/C)
(N/C)
(COM)
5
3
1
5
3
1
2
4
6
2
4
6
5
3
1
2
4
6
2
(N)
1
(COM)
3
(N/O)
4
(N/C)
DEFROST
STAT
MAKES 1 T
O 3 ON TEMP F
ALLING
A1
A1
A2
A2
3
N/C
(COM)
(N/O)
16
A1
A2
18
15
6
MINS
(COM)
(N/C)
(N/O)
4
7
RELA
Y 2
1
(COM)
(N/C)
(N/O)
1
9
7
RELA
Y 1
4
6
3
(COM)
(COM)
(N/C)
(N/C)
(N/O)
(N/O)
B
A
B
A
(N/O)
63
64
COMP A
UX
6 MINS
DELA
Y TIMER 2
SMAR
T CL
OCK
18
SD331851 ISSUE 28
AW834,1234AH/BH,1534BH AW 3034,7034H/HY OWNER INSTALLATION MANUAL