![Dantel 46022-30 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/dantel/46022-30/46022-30_installation-and-operation-manual_3470794006.webp)
P
AGE
6
46022-30-0198 <90-00067>
INSTALLATION
I
nstallation consists of setting the switches, installing the
communications subassembly, wiring the shelf (if necessary),
and installing the module in the shelf.
1. S
WITCHES
Setting the channel and card addresses is accomplished by the
five-lever mini-DIP switch S1. Refer to Fig. 4 and Table A.
S1-1, S1-2
These set the card address which identifies this MAC as having
the same address as the 46022-12 it is emulating.
S1-3 through S1-5
These set the channel address which identifies which data port
of the MAC-12 the MAC-30 is to emulate.
F
IG
. 4 - S
WITCH
L
OCATIONS
, 46022-30
CONTINUED
. . .
S1
1 2 3 4
OFF
ON
5
CHANNEL ADDRESS
CARD ADDRESS
1
SUBASSEMBLY
MOUNTING
AREA
13
1
4
J5
J4