OPERATION

O

peration of the 46020 MAP is a function of the firmware

 installed on the module. Refer to the appropriate Firmware

Manual for operating information. The module starts operation

when power is applied.
The front panel of the MAP has a green LED labeled “DATA

XMT”. This LED flashes when data is being transmitted from

the data port. A button labeled “RESET” is recessed below the

level of the front panel and is used to manually reset the MAP’s

microprocessor and associated circuitry.

TECHNICAL SPECIFICATION

DESCRIPTION

Input Voltage

Input Current (+15%)

@ -21 VDC

@ -24 VDC

@ -48 VDC
@ -56 VDC

Heat Dissipation (minus firmware or communications subassembly

@ -21 VDC
@ -24 VDC

@ -48 VDC

@ -56 VDC

Weight (without communications subassembly)

Physical Dimensions

Operating Temperature Range

VALUE

-21 to -56 VDC

113 mA

104 mA

73 mA
71 mA

8.1 Btu/Hr.
8.5 Btu/Hr.

12.0 Btu/Hr.

13.6 Btu/Hr.

11.25 ounces

1.4" x 6.0" x 5.6"

0° to 55° C.

Содержание 46020

Страница 1: ...nformation on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1997 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Regi...

Страница 2: ...l points using serial ports or Dantel s 46028 Control Point Modules CPMs I O devices can include computers dumb terminals and alarm system components by other manufacturers The MAP is a plug in printe...

Страница 3: ...Transmit Data RXD Receive Data 32 31 30 29 39 41 40 42 23 24 25 26 46 45 43 44 54 51 53 55 50 49 56 52 8 MEMORY MEMORY MEMORY MEMORY DECODER PORT 3 MASTER ADR CPU ADR PARALLEL INPUT OUTPUT 35 17 POWER...

Страница 4: ...n the power supply provides operating power for an optional communications subassembly CIRCUIT DESCRIPTION INSTALLATION This sections consists of installing the communication subas sembly if necessary...

Страница 5: ...he documentation for the firmware installed on the MAP Module Mounting Normally the 56 pin edge connector in the shelf is prewired at the factory If you are going to wire the connector refer to Fig 3...

Страница 6: ...3 W3 W2 DTR DCD RD RTS RTS EXTERNAL INTERRUPT PRINTER PORT PRINTER PORT MULTIPLE ALARM COMBINER AUXILIARY INPUT OUTPUT MULTIPLE ALARM COMBINER LEVEL A LEVEL C SUMMARY ALARM MODULE R3 R1 DTR DSR CTS TT...

Страница 7: ...ort A button labeled RESET is recessed below the level of the front panel and is used to manually reset the MAP s microprocessor and associated circuitry TECHNICAL SPECIFICATION DESCRIPTION Input Volt...

Страница 8: ...instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respecti...

Отзывы: