Dantel 44124 Скачать руководство пользователя страница 10

P

AGE

 10

44124-0798 <90-00024>

C

HECKOUT

Use the following equipment to test the 44124 DCTM:

A Dantel A15-00440-00 56-pin extender card or equivalent.

A Hewlett-Packard 3551 or equivalent voice frequency gen-
erator.

Test cables.

1. Mount the 44124 DCTM into the extender card.

1.

Plug the card into the appropriately wired slot.

2.

Set all the gain and equalization switches to OFF.

2. Use the transmission test set to record cable losses.

1.

Have the distant end transmit a tone at a level of 0 dBmO.

2.

Use the transmission test set programmed for bridged input level
measurement. Insert the test cord into the RCV MON jack (refer to
Fig. 5 for a 44124 DCTM front panel view). Record the cable losses
(in dB) at the receive line end for the 404 Hz, 1004 Hz, 2504 Hz,
and 3204 Hz frequencies.

3. Determine measurements and set switches.

1.

Determine the difference (in dB) between cable loss measurements
at 404 Hz and 1004 Hz (the LF slope of the cable).

If the LF slope is equal to or greater than 3.0 dB, set S8-1 ON
(nonloaded cable). Set LF slope (SL) settings of switches S8-2 to
S8-5 using the Nonloaded Cable column of Table B.

If the LF slope is less than 3.0 dB, set S8-1 to OFF (loaded cable).
Set LF slope (SL) settings of switches S8-2 to S8-5 using the
Loaded Cable column of Table B.

2.

Determine the difference (in dB) between cable loss measurements
at 1004 Hz and 3204 Hz (the height for the cable).

3.

Set height with switches S7-1 to S7-4. Refer to Table C.

4.

Determine the difference (in dB) between cable loss measurements
at 1004 Hz and 2504 Hz (the difference of the cable).

5.

Set bandwidth with switches S7-5 to S7-8. Refer to Tables D and E.

4. Set gain or loss.

1.

Set the input (receive) gain or loss as follows (Refer to Table A and
Fig. 3):

• Set the level meter to 600 ohms.

• Plug the test cord into the RCV OUT jack (Refer to Fig. 5).

• Have the far end transmit a 1004 Hz tone at 0 dBmO.

• Set switch S13 for gain or loss.

F

IG

. 5 - F

RONT

 P

ANEL

 V

IEW

INSTALLATION

CONTINUED

 . . .

B11-44124-00 REV__

44124-00

DATA STATION

TERMINATION

PWR

LB

SC

MON

OUT

IN/2W

MON

IN

OUT

A

T

O

B

B

T

O

A

Содержание 44124

Страница 1: ...For more complete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered trademark of Dant...

Страница 2: ...equal ization control are required The 44124 DCTM provides Data channel line conditioning that includes Impedance matching Selectable gain and attenuation control Adjustable 309B type post equalizati...

Страница 3: ...xed at 600 ohms Input Equalizer Circuit The input equalizer circuit receives an incoming signal from the impedance matching transformer T1 The circuit adjusts slope bandwidth and amplitude before the...

Страница 4: ...OR CONTROL ACCUMULATIVE SETTINGS INPUT AMPLIFIER CIRCUIT ACCUMULATIVE SETTINGS OUTPUT AMPLIFIER ACCUMULATIVE SETTINGS K1 LOOPBACK RELAYS S8 SLOPE S7 BANDWIDTH S7 AMPLIFIER HT S12 LOOPBACK LEVEL S11 dB...

Страница 5: ...8 seconds Tone detection provides remote testing of the facility and its active components A guard circuit prevents signal frequencies near 2713 Hz from enabling the loopback feature Set switch S12 3...

Страница 6: ...ates improper switching or reversed simplex lead polarity Set simplex lead polarity with switch S5 Regulated Power Supply The regulated power supply furnishes all 44124 DCTM power requirements It supp...

Страница 7: ...T e r i W r u o F 0 1 S 0 1 S W 2 W 4 k c a b p o o L z H 3 1 7 2 e l b a n E e l b a s i D 2 2 1 S 2 2 1 S D T D t u o e m i T k c a b p o o L z H 3 1 7 2 s e t u n i M 4 s e t u n i M 0 2 1 2 1 S 1...

Страница 8: ...a u q E t c e l e S d e d a o L d e d a o l n o N 1 8 S 1 8 S L N n i a G l e v e L t u p n I t c e l e S s s o L n i a G s s o L 3 1 S 3 1 S G L l e v e L t u p n I e v i t a l u m u c c a B d f f o...

Страница 9: ...9 8 7 6 5 4 3 2 1 CIRCUIT SIDE OF PC BOARD COMPONENT SIDE OF PC BOARD RCV Input Drop Side TIP A T2 Simplex RCV Input Drop Side RING XMT Output Line Side TIP SX1 XMT Output Line Side RING 21 to 56 VDC...

Страница 10: ...the cable If the LF slope is equal to or greater than 3 0 dB set S8 1 ON nonloaded cable Set LF slope SL settings of switches S8 2 to S8 5 using the Nonloaded Cable column of Table B If the LF slope...

Страница 11: ...using INSTALLATION TABLE B LF SLOPE SL SETTINGS FOR LOADED AND NONLOADED CABLES NOTE If the calculated values of Slope SL fall between settings use the lower setting indicated by the table LOSS AT 100...

Страница 12: ...1 75 2 45 3 15 3 85 4 55 5 25 5 95 6 65 7 35 8 05 8 75 9 45 10 15 Reference Total OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 S7 1 1 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON S7 2 2 OFF OFF...

Страница 13: ...ed by the table Reference Total 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 S7 5 1 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON S7 6 2 OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON S7 7...

Страница 14: ...52 1 67 1 82 1 98 2 13 2 28 7 0 23 0 46 0 69 0 92 1 15 1 38 1 61 1 84 2 07 2 30 2 53 2 76 2 99 3 22 3 45 8 0 27 0 55 0 82 1 09 1 37 1 64 1 91 2 19 2 46 2 73 3 01 3 28 3 55 3 83 4 10 9 0 30 0 60 0 90 1...

Страница 15: ...i l a e s r H u t B 8 4 r H u t B 3 2 1 e v i t c A k c a b p o o L g n i e b t n e r r u c g n i l a e s o n d e t a r e n e g r H u t B 4 5 r H u t B 0 4 1 n i a G B d 4 2 n o i t a z i l a u q E 6...

Страница 16: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...

Отзывы: