P
AGE
14
44118-0798 <90-00003>
STEP
1
2
3
4
5
6
7
8
ACTION
A) Remove power from the module
receptacle.
B) Plug in 44118 module.
C) Apply power
Calibrate module #1 first. (It doesnt
matter which one is called #1.) Connect a
600 ohm terminated dB meter across the
600 ohm output from the signal
generator. Set generator frequency
to 1 KHz.
Connect the 600 ohm terminated dB level
meter to the COMBINED DIST
OUTPUT jack (J9) on the 44118 front
panel.
Connect the signal generator to the LINE
RCV PORT 1 jack (J1) on the 44118 front
panel.
Move signal generator to the LINE RCV
PORT 2 jack (J3). Reset for port 2
receive level, if necessary.
Move signal generator to the LINE RCV
PORT 3 jack (J5). Reset for port 3
receive level, if necessary.
Move signal generator to the LINE RCV
PORT 4 jack (J7). Reset for port 2
receive level, if necessary.
Leave the signal generator connected to
J7 for steps 9 through 11. Do not change
generator level. Do not readjust any
receive level controls.
RESULTS
Adjust generator level for reading equal to system
line receive test tone level (0 dBmO) for port 1. This
level will be between -16 and +7 dBm, according to
your companys requirements.
Leave the dB meter connected to J9 for steps 4
through 7.
Read distribution level on meter. Adjust the LINE
RCV PORT 1 level control (R7) for reading of
-10 dBm, or appropriate distribution level for the
system, if different. If desired level cannot be
reached, move the 1R gain strap to the HI or LO
position, as required.
Read distribution level on meter. Adjust the LINE
RCV PORT 2 level control (R24) for reading of
-10 dBm, or appropriate distribution level for the
system, if different. If desired level cannot be
reached, move the 2R gain strap to the HI or LO
position, as required.
Read distribution level on meter. Adjust the LINE
RCV PORT 3 level control (R38) for reading of
-10 dBm, or appropriate distribution level for the
system, if different. If desired level cannot be
reached, move the 3R gain strap to the HI or LO
position, as required.
Read distribution level on meter. Adjust the LINE
RCV PORT 4 level control (R54) for reading of
-10 dBm, or appropriate distribution level for the
system, if different. If desired level cannot be
reached, move the 4R gain strap to the HI or LO
position, as required.
CONTINUED
. . .
INSTALLATION
T
ABLE
D - E
IGHT
-W
AY
/ F
OUR
-W
IRE
B
RIDGE
A
PPLICATION
C
ALIBRATION
P
ROCEDURE